Volume Assessment in Hemodialysis: A Comparison of Present Methods in Clinical Practice with Sonographic Lung Comets

被引:10
|
作者
Annamalai, Ishwarya [1 ]
Balasubramaniam, Suhasini [2 ]
Fernando, M. Edwin [1 ]
Srinivasaprasad, N. D. [1 ]
Suren, S. [1 ]
Thirumalvalavan, K. [1 ]
Veerakumar, A. M. [3 ]
机构
[1] Govt Stanley Hosp, Dept Nephrol, Chennai, Tamil Nadu, India
[2] Govt Stanley Hosp, Dept Radiol, Old Jail Rd, Chennai 600001, Tamil Nadu, India
[3] Govt Stanley Hosp, Dept Community Med, Chennai, Tamil Nadu, India
关键词
B lines; hemodialysis; high-resolution computed tomography; lung ultrasound; FLUID STATUS ASSESSMENT; PULMONARY CONGESTION; CHEST ULTRASOUND; MORTALITY; WEIGHT; WATER;
D O I
10.4103/ijn.IJN_78_18
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Dry weight assessment in dialysis patients remains a challenging endeavor owing to the limitations of the available methods for volume assessment. Lung ultrasound is emerging as an invaluable tool to assist in the appropriate assessment and assignment of dry weight. The objectives of this study are (1) to determine the reliability of clinical signs and symptoms for volume assessment, (2) to compare lung ultrasound with High Resolution Computed Tomography (HRCT) chest-A noninvasive gold standard tool for detecting pulmonary congestion and with inferior vena cava diameter (IVCD) - another time-tested volume assessment method, and (3) to analyze if lung ultrasound could detect dialysis induced fluid status variations. The cross-sectional study involves 50 patients on maintenance hemodialysis. Lung ultrasound for B line estimation and ultrasonographic measurement of IVCD performed before and after hemodialysis by a nephrologist trained in ultrasonography. Limited HRCT was obtained just before hemodialysis. Edema, crackles, and dyspnea had a poor sensitivity of 37.9%, 11.5%, and 52.6%, respectively, to detect clinically significant pulmonary congestion by lung ultrasound. A highly significant correlation was obtained between B-line score and HRCT signs of pulmonary congestion (P < 0.001) before dialysis. B lines showed statistically significant reduction with dialysis. The absolute reduction of B lines showed significant correlation with ultrafiltration volume and weight loss. Bedside lung ultrasound appears a sensitive tool for evaluating real-time changes in extravascular lung water and would serve to optimize volume status in dialysis patients.
引用
收藏
页码:102 / 110
页数:9
相关论文
共 50 条
  • [31] Effectiveness of Bronchoscopic Lung Volume Reduction with Endobronchial Valves in Clinical Practice
    Zantah, M.
    Gangemi, A. J.
    Castillo, E. Dominguez
    Pandya, A.
    Dorey-Stein, Z. L.
    Patel, M.
    Zheng, M.
    Thomas, J.
    Patlakh, N.
    Criner, L. H.
    Marchetti, N.
    Criner, G. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [32] CLINICAL COMPARISON OF 2 METHODS OF CALCULATING AMINOGLYCOSIDE VOLUME OF DISTRIBUTION
    PEARSON, VE
    MARTIN, ED
    THARP, LK
    CHANDLER, MHH
    CLINICAL PHARMACY, 1989, 8 (03): : 184 - 185
  • [33] ASSESSMENT OF GLOMERULAR-FILTRATION RATE IN INFANTS - COMPARISON OF 3 METHODS USED IN CLINICAL-PRACTICE
    ALINEI, P
    GUIGNARD, JP
    HELVETICA PAEDIATRICA ACTA, 1988, 42 (04) : 253 - 262
  • [34] Application of bioimpedance analysis for assessment of volume status in hemodialysis patients: Comparison with echocardiographic parameters
    Demirci, Cenk
    Ozkahya, Mehmet
    Gok, Soner
    Kayikcioglu, Meral
    Yucedag, Yuksel
    Yucedag, Dilhan
    Peker, Yesim
    Kinay, Banu
    Bertan, Ertan
    Ilaslan, Ali
    Kircelli, Fatih
    Toz, Huseyin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 143 - 144
  • [35] Assessment of the scope and quality of clinical practice guidelines in lung cancer
    Harpole, LH
    Kelley, MJ
    Schreiber, G
    Toloza, EM
    Kolimaga, J
    McCrory, DC
    CHEST, 2003, 123 (01) : 7S - 20S
  • [36] Comparison of different two methods in volume assessment and interrater reliability of these methods: a pilot study
    Akbayrak, Turkan
    Kaya, Serap
    Deligoz, Esma Duru
    Yakut, Yavuz
    TURKISH JOURNAL OF PHYSIOTHERAPY REHABILITATION-FIZYOTERAPI REHABILITASYON, 2007, 18 (03): : 217 - 222
  • [37] COMPARISON OF 2 INDIRECT CLINICAL-ASSESSMENT METHODS
    SMALES, RJ
    RUPINSKAS, L
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 481 - 481
  • [38] Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods
    Chromy, Adam
    Zalud, Ludek
    Dobsak, Petr
    Suskevic, Igor
    Mrkvicova, Veronika
    SPRINGERPLUS, 2015, 4 : 1 - 15
  • [39] Antidepressants in clinical practice: Limitations of assessment methods and drug response
    Kennedy, SH
    Eisfeld, BS
    Meyer, JH
    Bagby, RM
    HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 2001, 16 (01) : 105 - 114
  • [40] Comparison of Bioimpedance and Clinical Methods for Dry Weight Prediction in Maintenance Hemodialysis Patients
    Jian, Yusu
    Li, Xiang
    Cheng, Xuyang
    Chen, Yuqing
    Liu, Li
    Tao, Zhenhui
    Zuo, Li
    BLOOD PURIFICATION, 2014, 37 (03) : 214 - 220