Endo-Modell Rotating-hinge Total Knee for Revision Total Knee Arthroplasty

被引:16
作者
Bistolfi, Alessandro [1 ]
Rosso, Federica [2 ]
Crova, Maurizio [1 ]
Massazza, Giuseppe [1 ]
机构
[1] Citta Salute & Sci, Dept Orthoped Traumatol & Rehabil, Turin, Italy
[2] Univ Turin, I-10126 Turin, Italy
关键词
HIGH-CRYSTALLINITY; RADIOLUCENT LINES; UNITED-STATES; REPLACEMENT; SURGERY; HIP;
D O I
10.3928/01477447-20130920-24
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell. All patients were evaluated preoperatively, 3 and 6 months postoperatively, and annually thereafter using the Hospital for Special Surgery (HSS) knee score and the Knee Society Roentgenographic Evaluation System (KS-RES). Mean follow-up was 155.2 +/- 40.1 months (range, 78-240 months), with 32 patients examined at the final follow-up. All HSS knee scores increased from preoperatively to last follow-up. No statistically significance differences were found in the HSS knee scores between septic and aseptic revisions and between total or partial revisions. Progressive radiolucent lines were detected in 8 (25%) patients. Implant failure occurred in 11 (20.7%) patients; the cumulative survival of the implants was 80.4% at 150 months for the final 32 patients. The authors recommend use of this implant for revision total knee arthroplasty, especially in patients with severe instability and bone loss.
引用
收藏
页码:E1299 / E1306
页数:8
相关论文
共 35 条
[1]   Progression of radiolucent lines in cementless twin-bearing low-contact-stress knee prostheses [J].
Aebli, N ;
Krebs, J ;
Schwenke, D ;
Hii, T ;
Wehrli, U .
JOURNAL OF ARTHROPLASTY, 2004, 19 (06) :783-789
[2]   Vitamin E Blended Uhmwpe May Have the Potential to Reduce Bacterial Adhesive Ability [J].
Banche, Giuliana ;
Bracco, Pierangiola ;
Bistolfi, Alessandro ;
Allizond, Valeria ;
Boffano, Michele ;
Costa, Luigi ;
Cimino, Andrea ;
Cuffini, Anna Maria ;
del Prever, Elena Maria Brach .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (11) :1662-1667
[3]   Rotating-hinge Total Knee for Revision Total Knee Arthroplasty [J].
Bistolfi, Alessandro ;
Massazza, Giuseppe ;
Rosso, Federica ;
Crova, Maurizio .
ORTHOPEDICS, 2012, 35 (03) :E325-E330
[4]   Tensile and Tribological Properties of High-Crystallinity Radiation Crosslinked UHMWPE [J].
Bistolfi, Alessandro ;
Turell, Mary Beth ;
Lee, Ying-Lung ;
Bellare, Anuj .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (01) :137-144
[5]   The infected total knee - Management options [J].
Cuckler, JM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :33-36
[6]   The structural allograft composite in revision total knee arthroplasty [J].
Dennis, DA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :90-93
[7]  
Engh G A, 1999, Instr Course Lect, V48, P167
[8]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[9]   The failed total knee arthroplasty: Evaluation and etiology [J].
Gonzalez, MH ;
Mekhail, AO .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (06) :436-446
[10]   99mTc-Fab′ Fragments (Sulesomab) for Imaging Septically Loosened Total Knee Arthroplasty [J].
Gratz, S. ;
Behr, T. M. ;
Reize, P. ;
Pfestroff, A. ;
Kampen, W. U. ;
Hoeffken, H. .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (01) :54-67