Time-domain fault location algorithm for parallel transmission lines using unsynchronized currents

被引:27
|
作者
Jiale, S
Song, GB
Xu, QQ
Chao, Q
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Dept Elect Power Syst & Automat, Xian 710049, Peoples R China
[2] Xin Jiang Univ, Sch Elect Engn, Dept Elect Power Syst & Automat, Urumqi 830008, Peoples R China
基金
中国国家自然科学基金;
关键词
parallel transmission lines; differential component net; fault location;
D O I
10.1016/j.ijepes.2005.11.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parallel transmission lines under fault can be decoupled into common component net and differential component net. For the differential component net is only composed by parallel lines part and its bus voltages are zero, the voltage distributions along differential component net can be calculated by each terminal current. The novel time-domain fault location algorithm is founded by voltage distributions from both terminals have the least difference at the fault point. The synchronization is achieved by searching the minimal value of locating criterion function, which is calculated by fixing one terminal data and moving another terminal data within a setting time. The proposed algorithm needs a very short data-window, any segment of fault data front transient to steady state can be used to locate faults, and no voltage data is needed. With distributed parameter model, simulations show that the locating errors are less than 0.1 km, and the fault types and fault resistances have no effect on locating accuracy. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [1] Time-domain fault location algorithm based on one-terminal current of parallel transmission lines
    School of Electric Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 7 (52-57):
  • [2] Novel time-domain fault location algorithm by two-terminal currents
    Gao, Shuping
    Song, Guobing
    Jiao, Zaibing
    Suonan, Jiale
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (04): : 101 - 105
  • [3] Accurate Time-Domain Fault Location Method on Practically Transposed Transmission Lines
    Lu, Dayou
    Liu, Yu
    Wang, Binglin
    Yi, Lihui
    Zheng, Xiaodong
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [4] An Improved Time-domain Fault-location Algorithm for HVDC Transmission Line
    Qiu, Yingdan
    Li, Haifeng
    Wu, Jiyang
    Guo, Yanxun
    Wang, Gang
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 2529 - 2533
  • [5] Time-Domain Fault-Location Method on HVDC Transmission Lines Under Unsynchronized Two-End Measurement and Uncertain Line Parameters
    Liang Yuansheng
    Gang, Wang
    Li Haifeng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1031 - 1038
  • [6] Fault Location in Multitapped Transmission Lines Using Unsynchronized Data and Superposition Theorem
    Morais de Pereira, Carlos Eduardo
    Zanetta, Luiz Cera, Jr.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2081 - 2089
  • [7] A New Algorithm for Wire Fault Location Using Time-Domain Reflectometry
    Shi, Qinghai
    Kanoun, Olfa
    IEEE SENSORS JOURNAL, 2014, 14 (04) : 1171 - 1178
  • [8] Time-domain based fault location for series compensated transmission lines without requiring fault type
    Ghazizadeh-Ahsaee, Mahdi
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 181
  • [9] TIME-DOMAIN ANALYSIS OF MULTIPLE PARALLEL TRANSMISSION LINES
    AMEMIYA, H
    RCA REVIEW, 1967, 28 (02): : 241 - &
  • [10] Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages
    Istrate, Marcel
    Miron, Alexandru
    Istrate, Cristiana
    Gusa, Mircea
    Machidon, Dragos
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2009, 9 (03) : 51 - 56