Automatic segmentation of carotid B-mode images using fuzzy classification

被引:19
|
作者
Rocha, Rui [1 ,2 ]
Silva, Jorge [1 ,3 ]
Campilho, Aurelio [1 ,4 ]
机构
[1] INEB Inst Engn Biomed, P-4200465 Oporto, Portugal
[2] ISEP Inst Super Engn Porto, P-4200072 Oporto, Portugal
[3] Univ Porto, Fac Engn, Dept Informat Engn, P-4200465 Oporto, Portugal
[4] Univ Porto, Fac Engn, P-4200465 Oporto, Portugal
关键词
Ultrasound image; Carotid; Image segmentation; Dynamic programming; Fuzzy edge detection; INTIMA-MEDIA THICKNESS; 2-D ULTRASOUND IMAGES; ARTERY WALL; MYOCARDIAL-INFARCTION; ATHEROSCLEROSIS RISK; CLINICAL MEASUREMENT; MEASUREMENT SYSTEM; HOUGH TRANSFORM; DISEASE; PLAQUE;
D O I
10.1007/s11517-012-0883-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a new method for the automatic segmentation of the common carotid artery in B-mode images. This method uses the instantaneous coefficient of variation edge detector, fuzzy classification of edges and dynamic programming. Several discriminating features of the intima and adventitia boundaries are considered, like the edge strength, the intensity gradient orientation, the valley shaped intensity profile and contextual information of the region delimited by those boundaries. The adopted fuzzy classification of edges helps avoiding low-pass filtering. The method is suited to real-time processing and user interaction is not required. Both the near and far wall boundaries can be detected in arteries with plaques of different types and sizes. Both expert manual and automatic tracings are significantly better for the far wall, due to the better visibility of the intima and adventitia boundaries. The automatic detection of the far wall shows an accuracy similar to the manual detections. For this wall, the error coefficient of variation for the mean intima-media thickness is in the range [5.6, 6.6 %] for automatic detections and in [6.7, 7.1 %] for manual ones. In the case of the near wall, the same coefficient of variation is in [11.2, 13.0 %] for automatic detections and in [5.9, 9.0 %] for manual detections. The mean intima-media thickness measurement errors observed for the far wall ([0.15; 0.17] mm, [1.7; 1.9] pixel) are among the best values reported for other fully automatic approaches. The application of this approach in clinical practice is encouraged by the results for the far wall and the short processing time (mean of 2.1 s per image).
引用
收藏
页码:533 / 545
页数:13
相关论文
共 50 条
  • [1] Automatic segmentation of carotid B-mode images using fuzzy classification
    Rui Rocha
    Jorge Silva
    Aurélio Campilho
    Medical & Biological Engineering & Computing, 2012, 50 : 533 - 545
  • [2] Automatic segmentation of the lumen of the carotid artery in ultrasound B-mode images
    Santos, Andre M. F.
    Tavares, Joao Manuel R. S.
    Sousa, Luisa
    Santos, Rosa
    Castro, Pedro
    Azevedo, Elsa
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [3] AUTOMATIC SEGMENTATION ALGORITHM FOR THE LUMEN OF THE CAROTID ARTERY IN ULTRASOUND B-MODE IMAGES
    Santos, Andre M. F.
    Tavares, Joao M. R. S.
    Sousa, Luisa
    Santos, Rosa
    Castro, Pedro
    Azevedo, Elsa
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [4] A novel automatic algorithm for the segmentation of the lumen of the carotid artery in ultrasound B-mode images
    Santos, Andre Miguel F.
    dos Santos, Rosa Maria
    Castro, Pedro Miguel A. C.
    Azevedo, Elsa
    Sousa, Luisa
    Tavares, Joao Manuel R. S.
    EXPERT SYSTEMS WITH APPLICATIONS, 2013, 40 (16) : 6570 - 6579
  • [5] Automatic Prostate Segmentation Using Fused Ultrasound B-Mode and Elastography Images
    Mahdavi, S. Sara
    Moradi, Mehdi
    Morris, William J.
    Salcudean, Septimiu E.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 76 - +
  • [6] Classification Approach for Measurement of Atherosclerosis Using B-Mode Ultrasound Carotid Images
    Carvalho, Catarina
    Rocha, Rui
    Campilho, Aurelio
    IMAGE ANALYSIS AND RECOGNITION, 2013, 7950 : 539 - 546
  • [7] Automatic Segmentation and Measurements of Gestational Sac Using Static B-Mode Ultrasound Images
    Ibrahim, Dheyaa Ahmed
    Al-Assam, Hisham
    Du, Hongbo
    Farren, Jessica
    Al-karawil, Dhurgham
    Bourne, Tom
    Jassim, Sabah
    MOBILE MULTIMEDIA/IMAGE PROCESSING, SECURITY, AND APPLICATIONS 2016, 2016, 9869
  • [8] Automatic detection of the carotid lumen axis in B-mode ultrasound images
    Rocha, Rui
    Silva, Jorge
    Campilho, Aurelio
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 115 (03) : 110 - 118
  • [9] Automatic Lumen Detection on Longitudinal Ultrasound B-Mode Images of the Carotid Using Phase Symmetry
    Rouco, Jose
    Azevedo, Elsa
    Campilho, Aurelio
    SENSORS, 2016, 16 (03):
  • [10] Segmentation of the carotid intima-media region in B-mode ultrasound images
    Rocha, Rui
    Campilho, Aurelio
    Silva, Jorge
    Azevedo, Elsa
    Santos, Rosa
    IMAGE AND VISION COMPUTING, 2010, 28 (04) : 614 - 625