Increase of Cortical Bone After a Cementless Long Stem in Periprosthetic Fractures

被引:17
作者
Garcia-Rey, Eduardo [1 ]
Garcia-Cimbrelo, Eduardo [1 ]
Cruz-Pardos, Ana [1 ]
Madero, Rosario [2 ]
机构
[1] Hosp La Paz IDi Paz, Dept Orthopaed, Madrid 28046, Spain
[2] Hosp La Paz IDi Paz, Dept Biostat, Madrid 28046, Spain
关键词
TOTAL HIP-ARTHROPLASTY; COATED FEMORAL COMPONENTS; SL REVISION STEM; FOLLOW-UP; FEMUR FRACTURES; REPLACEMENT; FIXATION; MANAGEMENT; ALLOGRAFT; ROTATION;
D O I
10.1007/s11999-013-2845-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Healing and functional recovery have been reported using an extensively porous-coated stem in Vancouver B2 and B3 periprosthetic fractures; however, loss of cortical bone has been observed when using these stems in revision surgery for aseptic loosening. However, it is unclear whether this bone loss influences subsequent loosening. We analyze the healing fracture rate and whether the radiographic changes observed around and extensively porous-coated stem used for periprosthetic fractures affect function or loosening. We retrospectively reviewed 35 patients with periprosthetic fractures (20 Vancouver B2 and 15 Vancouver B3). Patients' mean age at surgery was 80 years (range, 51-86 years). No cortical struts were used in this series. We evaluated radiographs for signs of loosening or subsidence. The cortical index and the femoral cortical width were measured at different levels on the immediate pre- and postoperative radiographs and at different periods of followup. The minimum followup was 3 years (mean, 8.3 years; range, 3-17 years). All fractures had healed, and all stems were clinically and radiographically stable at the end of followup. Nineteen hips showed nonprogressive radiographic subsidence during the first 3 postoperative months without clinical consequences. The cortical index and the lateral and medial cortical thickness increased over time. Increase of femoral cortex thicknesses was greater in cases with moderate preoperative osteoporosis and in cases with stems less than 16 mm in thickness. Our data suggest an extensively porous-coated stem for Vancouver B2 and B3 periprosthetic fractures leads to a high rate of union and stable fixation. Cortical index and lateral cortex thickness increased in these patients with periprosthetic fractures. Patients with moderate osteoporosis and those using thin stems showed a major increase in femoral cortex thickness over time. Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:3912 / 3921
页数:10
相关论文
共 40 条
[1]  
BELL AL, 1989, CLIN ORTHOP RELAT R, P194
[2]   Treatment of Vancouver B3 periprosthetic femur fractures with a fluted tapered stem [J].
Berry, DJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :224-231
[3]  
Böhm P, 2001, J BONE JOINT SURG AM, V83A, P1023
[4]  
BOSCO JA, 1993, CLIN ORTHOP RELAT R, P131
[5]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[6]  
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
[7]  
Eckrich S G, 1994, J Arthroplasty, V9, P419, DOI 10.1016/0883-5403(94)90053-1
[8]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, P63
[9]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[10]   Stress-shielding of the proximal femur using an extensively porous-coated femoral component without allograft in revision surgery A 5-TO 17-YEAR FOLLOW-UP STUDY [J].
Garcia-Cimbrelo, E. ;
Garcia-Rey, E. ;
Cruz-Pardos, A. ;
Madero, R. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (10) :1363-1369