Evaluation of lumbar spine motion with dynamic X-ray -: A reliability analysis

被引:33
作者
Cakir, Balkan [1 ]
Richter, Marcus [1 ]
Kaefer, Wolfram [1 ]
Wieser, Michael [1 ]
Puhl, Wolfhart [1 ]
Schmidt, Rene [1 ]
机构
[1] Univ Ulm, Dept Orthopaed & Spinal Cord Injury, Ulm, Germany
关键词
lumbar spine; functional radiography; reliability; lumbar range of motion;
D O I
10.1097/01.brs.0000217763.80593.50
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Radiologic evaluation of lumbar range of motion ( ROM) with dynamic radiograph. Objectives. To calculate 95% confidence intervals (CIs) for the measurement error accompanying different methods, different observers, and different levels of training when measuring sagittal plane segmental ROM in lumbar spine. In addition, to compare the 95% CI with frequently common statistical methods of reliability analysis. Summary of Background Data. Dynamic radiographs are commonly used for ROM calculation of the lumbar spine. Yet, the reliability of different measurement methods still remains unclear. Methods. In 24 patients, levels L4-L5 and L5-S1 were measured with the Cobb and superimposition methods on flexion-extension radiographs. There were 2 experienced and 1 inexperienced observer that performed the measurements. The 95% CIs were compared with the corresponding Pearson correlation coefficient and P value (t test). Results. The 95% CI of the superimposition method was +/- 4.0 for the experienced and +/- 4.7 for the inexperienced observer. The corresponding values for the Cobb method was +/- 4.2 degrees for the experienced and +/- 6.8 degrees for the inexperienced observer. The 95% CI for the measurement error became even worse when different methods or observers were compared, whereas a method constancy revealed superior reliability than observer constancy in experienced observers. Conclusions. For lumbar ROM measurement with dynamic radiograph, the superimposition method seems to be more reliable than the Cobb method. Study protocols dealing with ROM measurement have to calculate the 95% CI of the measurement method used because clinically valid conclusions can only be drawn with respect to these intervals.
引用
收藏
页码:1258 / 1264
页数:7
相关论文
共 31 条
  • [1] A TECHNIQUE FOR QUANTIFYING THE BENDING MOMENT ACTING ON THE LUMBAR SPINE INVIVO
    ADAMS, MA
    DOLAN, P
    [J]. JOURNAL OF BIOMECHANICS, 1991, 24 (02) : 117 - 126
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] LUMBOSACRAL SEGMENTAL MOTION IN NORMAL INDIVIDUALS - HAVE WE BEEN MEASURING INSTABILITY PROPERLY
    BODEN, SD
    WIESEL, SW
    [J]. SPINE, 1990, 15 (06) : 571 - 576
  • [4] Sagittal alignment and segmental range of motion after total disc replacement of the lumbar spine
    Cakir, B
    Schmidt, R
    Huch, K
    Puhl, W
    Richter, M
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (02): : 159 - 165
  • [5] MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION
    CARMAN, DL
    BROWNE, RH
    BIRCH, JG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) : 328 - 333
  • [6] LUMBAR POSTERIOR LIGAMENT INVOLVEMENT DURING EXTREMELY HEAVY LIFTS ESTIMATED FROM FLUOROSCOPIC MEASUREMENTS
    CHOLEWICKI, J
    MCGILL, SM
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (01) : 17 - 28
  • [7] Relationship between pain and vertebral motion in chronic low-back pain subjects
    Dickey, JP
    Pierrynowski, MR
    Bednar, DA
    Yang, SX
    [J]. CLINICAL BIOMECHANICS, 2002, 17 (05) : 345 - 352
  • [8] MOTION OF THE LUMBAR SPINE - RELIABILITY OF 2 MEASUREMENT TECHNIQUES
    DILLARD, J
    TRAFIMOW, J
    ANDERSSON, GBJ
    CRONIN, K
    [J]. SPINE, 1991, 16 (03) : 321 - 324
  • [9] CLINICAL VALIDATION OF FUNCTIONAL FLEXION EXTENSION ROENTGENOGRAMS OF THE LUMBAR SPINE
    DVORAK, J
    PANJABI, MM
    NOVOTNY, JE
    CHANG, DG
    GROB, D
    [J]. SPINE, 1991, 16 (08) : 943 - 950
  • [10] DVORAK J, 1991, SPINE, V16, P562