Validity of total and segmental impedance measurements for prediction of body composition across ethnic population groups

被引:61
作者
Deurenberg, P
Deurenberg-Yap, M
Schouten, FJM
机构
[1] Univ Wageningen & Res Ctr, Dept Nutr & Epidemiol, Wageningen, Netherlands
[2] Univ Roma Tor Vergata, Dept Human Physiol, Rome, Italy
[3] Hlth Promot Board, Res & Hlth Informat Management Dept, Singapore, Singapore
关键词
body composition; total body water; body water distribution; segmental bioelectrical impedance; validation; ethnic groups;
D O I
10.1038/sj.ejcn.1601303
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objectives: To test the impact of body build factors on the validity of impedance-based body composition predictions across (ethnic) population groups and to study the suitability of segmental impedance measurements. Design: Cross-sectional observational study. Settings: Ministry of Health and School of Physical Education, Nanyang Technological University, Singapore. Subjects: A total of 291 female and male Chinese, Malays and Indian Singaporeans, aged 18 - 69, body mass index (BMI) 16.0 - 40,2 kg/m(2). Methods: Anthropometric parameters were measured in addition to impedance (100 kHz) of the total body, arms and legs. Impedance indexes were calculated as height(2)/impedance. Arm length (span) and leg length (sitting height), wrist and knee width were measured from which body build indices were calculated. Total body water (TBW) was measured using deuterium oxide dilution. Extra cellular water (ECW) was measured using bromide dilution. Body fat percentage was determined using a chemical four-compartment model. Results: The bias of TBW predicted from total body impedance index (bias: measured minus predicted TBW) was different among the three ethnic groups, TBW being significantly underestimated in Indians compared to Chinese and Malays. This bias was found to be dependent on body water distribution (ECW/TBW) and parameters of body build, mainly relative (to height) arm length. After correcting for differences in body water distribution and body build parameters the differences in bias across the ethnic groups disappeared. The impedance index using total body impedance was better correlated with TBW than the impedance index of arm or leg impedance, even after corrections for body build parameters. Conclusions: The study shows that ethnic-specific bias of impedance-based prediction formulas for body composition is due mainly to differences in body build among the ethnic groups. This means that the use of 'general' prediction equations across different (ethnic) population groups without prior testing of their validity should be avoided. Total body impedance has higher predictive value than segmental impedance.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 1963, BODY COMPOSITION HLT
[2]  
[Anonymous], 1998, OB PREV MAN GLOB EP
[3]  
[Anonymous], BODY COMPOSITION TEC
[4]   BODY-COMPOSITION IN ELDERLY PEOPLE - EFFECT OF CRITERION ESTIMATES ON PREDICTIVE EQUATIONS [J].
BAUMGARTNER, RN ;
HEYMSFIELD, SB ;
LICHTMAN, S ;
WANG, J ;
PIERSON, RN .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (06) :1345-1353
[5]   ESTIMATION OF BODY-COMPOSITION FROM BIOELECTRIC IMPEDANCE OF BODY SEGMENTS [J].
BAUMGARTNER, RN ;
CHUMLEA, WC ;
ROCHE, AF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 50 (02) :221-226
[6]   The specific gravity of healthy men - Body weight divided by volume as an index of obesity [J].
Behnke, AR .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1942, 118 :495-498
[7]  
DEMPSTER P, 1995, MED SCI SPORTS EXERC, V27, P419
[8]   The impact of body build on the relationship between body mass index and percent body fat [J].
Deurenberg, P ;
Yap, MD ;
Wang, J ;
Lin, FP ;
Schmidt, G .
INTERNATIONAL JOURNAL OF OBESITY, 1999, 23 (05) :537-542
[9]   MULTIFREQUENCY IMPEDANCE FOR THE PREDICTION OF EXTRACELLULAR WATER AND TOTAL-BODY WATER [J].
DEURENBERG, P ;
TAGLIABUE, A ;
SCHOUTEN, FJM .
BRITISH JOURNAL OF NUTRITION, 1995, 73 (03) :349-358
[10]  
DEURENBERG P, 1989, EUR J CLIN NUTR, V43, P845