A new beryllium ion-selective membrane electrode based on dibenzo(perhydrotriazino)aza-14-crown-4 ether

被引:34
作者
Gupta, Vinod Kumar [1 ]
Singh, Ashok Kumar [1 ]
Mergu, Naveen [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
Beryllium selective electrode; Dibenzo(perhydrotriazino)aza-14-crown-4 ether; Poly(vinyl chloride) membrane; Potentiometry; ATOMIC-ABSORPTION-SPECTROMETRY; PVC MATRIX MEMBRANE; POTENTIOMETRIC SENSOR; PHARMACEUTICAL FORMULATIONS; EMISSION-SPECTROMETRY; BIOLOGICAL-FLUIDS; NATURAL-WATERS; FLOW-INJECTION; TRACE AMOUNTS; ROCK SAMPLES;
D O I
10.1016/j.aca.2012.08.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Beryllium(II) selective electrodes have been fabricated based on poly(vinyl chloride) (PVC) matrix membranes containing newly synthesized neutral carrier dibenzo(perhydrotriazino)aza-14-crown-4 ethers as ionophore. Best performance was exhibited by the membrane having a composition ionophore (Ila):PVC:sodium tetraphenylborate (NaTPB):tributyl phosphate (TBP) in the ratio (w/w; mg) of 5:30:3:65. This membrane worked well over a wide concentration range 7.6 x 10(-6) to 1.0 x 10(-1) M of Be2+ with a Nernstian slope of 30.7 mV per decade of beryllium activity. The response time of the sensor is 15s and the membrane can be used over a period of 4 months with good reproducibility. The proposed electrode works well in a wide pH range 3.0-9.0. It was successfully applied to the determination of beryllium in a mineral sample. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
[41]   Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier [J].
Aghaie, M. ;
Giahi, M. ;
Zawari, M. .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (10) :2980-2984
[42]   Erbium(III) PVC Membrane Ion-Selective Sensor based on 4-(2-Thiazolylazo)resorcinal [J].
Nekoei, Mehdi ;
Zamani, Hassan Ali ;
Mohammadhossieni, Majed .
ANALYTICAL LETTERS, 2009, 42 (02) :284-297
[43]   Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore [J].
Esmaelpourfarkhani, Masoomeh ;
Rounaghi, Gholam H. ;
Arbab-Zavar, Mohammad H. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (05) :963-969
[44]   Fe(III) ion-selective membrane electrode based on 4-amino-6-methyl-3-methylmercapto-1,2,4-triazin-5-one [J].
Pooyamanesh, Mohammad Jan ;
Zamani, Hassan Ali ;
Rajabzadeh, Ghadir ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz .
ANALYTICAL LETTERS, 2007, 40 (08) :1596-1609
[45]   Design and construction of ion-selective electrode based on a new Schiff base and its application in determination of copper(II) ions [J].
Valilue, Z. ;
Vardin, M. T. ;
Kalhor, E. Ghorbani .
INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2016, 55 (01) :51-56
[46]   Potentiometric aptasensing based on target-induced conformational switch of a DNA probe using a polymeric membrane silver ion-selective electrode [J].
Ding, Jiawang ;
Qin, Wei ;
Zhang, Yan ;
Wang, Xuewei .
BIOSENSORS & BIOELECTRONICS, 2013, 45 :148-151
[47]   New Simple Ion-Selective Membrane Electrode for Serious Environmental Pollutant, Mercury (II), Analysis in Aqueous Solution, Fluorescent Mercury Lamp White Dust, Mercurochrome and Dental Alloy [J].
Hassan, Abeer M. E. ;
Ahmed, Hytham M. ;
Aboul-Enein, Hassan Y. .
CURRENT ANALYTICAL CHEMISTRY, 2018, 14 (01) :36-42
[48]   Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore [J].
Arvand, M. ;
Zanjanchi, M. A. ;
Heydari, L. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :301-308
[49]   Electroanalytical Studies on Cobalt(II) Ion-Selective Sensor of Polymeric Membrane Electrode and Coated Graphite Electrode Based on N2O2 Salen Ligands [J].
Bandi, Koteswara Rao ;
Singh, Ashok Kumar ;
Jain, Kamaluddin A. K. ;
Gupta, V. K. .
ELECTROANALYSIS, 2011, 23 (12) :2839-2850
[50]   Development of New Copper(II) Ion-Selective Poly(vinyl chloride) Membrane Electrode Based on 2,6-Diacetylpyridine-(1R)-(-)-Fenchone Diazine Ligand [J].
Isa, Illyas Md ;
Saidin, Mohamad Idris ;
Ahmad, Mustaffa ;
Hashim, Norhayati ;
Ghani, Sazelli A. ;
Si, Suyanta M. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (09) :11175-11185