A new beryllium ion-selective membrane electrode based on dibenzo(perhydrotriazino)aza-14-crown-4 ether

被引:34
作者
Gupta, Vinod Kumar [1 ]
Singh, Ashok Kumar [1 ]
Mergu, Naveen [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
Beryllium selective electrode; Dibenzo(perhydrotriazino)aza-14-crown-4 ether; Poly(vinyl chloride) membrane; Potentiometry; ATOMIC-ABSORPTION-SPECTROMETRY; PVC MATRIX MEMBRANE; POTENTIOMETRIC SENSOR; PHARMACEUTICAL FORMULATIONS; EMISSION-SPECTROMETRY; BIOLOGICAL-FLUIDS; NATURAL-WATERS; FLOW-INJECTION; TRACE AMOUNTS; ROCK SAMPLES;
D O I
10.1016/j.aca.2012.08.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Beryllium(II) selective electrodes have been fabricated based on poly(vinyl chloride) (PVC) matrix membranes containing newly synthesized neutral carrier dibenzo(perhydrotriazino)aza-14-crown-4 ethers as ionophore. Best performance was exhibited by the membrane having a composition ionophore (Ila):PVC:sodium tetraphenylborate (NaTPB):tributyl phosphate (TBP) in the ratio (w/w; mg) of 5:30:3:65. This membrane worked well over a wide concentration range 7.6 x 10(-6) to 1.0 x 10(-1) M of Be2+ with a Nernstian slope of 30.7 mV per decade of beryllium activity. The response time of the sensor is 15s and the membrane can be used over a period of 4 months with good reproducibility. The proposed electrode works well in a wide pH range 3.0-9.0. It was successfully applied to the determination of beryllium in a mineral sample. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
  • [31] Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a p-tert-butylcalix[4]arene-oxacrown-4
    Demirel, A
    Dogan, A
    Canel, E
    Memon, S
    Yilmaz, M
    Kiliç, E
    [J]. TALANTA, 2004, 62 (01) : 123 - 129
  • [32] A novel Ce(IV) ion-selective polyvinyl chloride membrane electrode based on HDEHP and HEH/EHP
    He Jingui
    Li Yong
    Xue Xiangxin
    Ru Hongqiang
    Huang Xiaowei
    Yang He
    [J]. JOURNAL OF RARE EARTHS, 2017, 35 (09) : 934 - 940
  • [33] A bromide ion-selective polymeric membrane electrode based on a benzo-derivative xanthenium bromide salt
    Shamsipur, M
    Rouhani, S
    Mohajeri, A
    Ganjali, MR
    Rashidi-Ranjbar, P
    [J]. ANALYTICA CHIMICA ACTA, 2000, 418 (02) : 197 - 203
  • [34] Characterization of a new ionophore-based ion-selective electrode for the potentiometric determination of creatinine in urine
    Guinovart, Tomas
    Hernandez-Alonso, Daniel
    Adriaenssens, Louis
    Blondeau, Pascal
    Rius, F. Xavier
    Ballester, Pablo
    Andrade, Francisco J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 87 : 587 - 592
  • [35] Ion-selective carbon paste electrode based on new tripodal ligand for determination of cadmium (II)
    Hossein Abbastabar-Ahangar
    Ali Shirzadmehr
    Katayoun Marjani
    Hamid Khoshsafar
    Marzieh Chaloosi
    Leila Mohammadi
    [J]. Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2009, 63 : 287 - 293
  • [36] Iodide ion-selective PVC membrane electrode based on a recently synthesized salen-Mn(II) complex
    Shamsipur, M
    Sadeghi, S
    Naeimi, H
    Sharghi, H
    [J]. POLISH JOURNAL OF CHEMISTRY, 2000, 74 (02) : 231 - 238
  • [37] NEW SILVER ION-SELECTIVE PVC MEMBRANE AND COATED-GRAPHITE ELECTRODES BASED ON A NOVEL CALIX[4]ARENE DERIVATIVE
    Erol, Sibel
    Ozel, Ayca Demirel
    Yilmaz, Mustafa
    Kilic, Esma
    [J]. REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 28 (01) : 27 - 49
  • [38] Construction of New Iodide Ion-Selective Electrodes Based on New Ionophores: Comparison of the Effect of Structures and Additives on Electrode Response
    Shokrollahi, Ardeshir
    Ghaedi, Mehrorang
    Kianfar, Ali Hossain
    Montazerozohori, Morteza
    Najibzadeh, Marziyeh
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (04) : 1208 - 1218
  • [39] Construction of a new solid-state U(VI) ion-selective electrode based on polypyrrole conducting polymer
    Reza Ansari
    Zahra Mosayebzadeh
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2014, 299 : 1597 - 1605
  • [40] Optimization of Polyaniline Supported Ti(IV) Arsenophosphate Composite Cation Exchanger Based Ion-Selective Membrane Electrode for the Determination of Lead
    Bushra, Rani
    Shahadat, Mohammad
    Khan, Meraj A.
    Inamuddin
    Adnan, Rohana
    Rafatullah, Mohd
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (50) : 19387 - 19391