Determination of Nickel in Water, Food, and Biological Samples by Electrothermal Atomic Absorption Spectrometry After Preconcentration on Modified Carbon Nanotubes

被引:10
作者
Taher, Mohammad Ali [1 ]
Mazaheri, Lida [2 ]
Ashkenani, Hamid [3 ,4 ]
Mohadesi, Alireza [2 ]
Afzali, Daryoush [5 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[2] Payame Noor Univ, Dept Chem, Kerman, Iran
[3] Islamic Azad Univ, Minab Branch, Dept Chem, Minab, Iran
[4] Shahid Bahonar Univ Kerman, Young Researchers Soc, Kerman, Iran
[5] Int Ctr Sci High Technol & Environm Sci, Res Inst Environm Sci, Dept Environm, Kerman, Iran
关键词
CLOUD POINT EXTRACTION; OPTICAL-EMISSION SPECTROMETRY; SOLID-PHASE EXTRACTION; TRACE AMOUNTS; POLYURETHANE FOAM; LEAD; COBALT; SILICA; COPPER; ZINC;
D O I
10.5740/jaoacint.12-327
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and sensitive SPE method using modified carbon nanotubes for extraction and preconcentration, and electrothermal atomic absorption spectrometric determination of nickel (Ni) in real samples at ng/L levels was investigated. First, multiwalled carbon nanotubes were oxidized with concentrated HNO3, then modified with 2-(5-bormo-2-pyridylazo)-5-diethylaminophenol reagent. The adsorption was achieved quantitatively on a modified carbon nanotubes column in a pH range of 6.5 to 8.5; the adsorbed Ni(II) ions were then desorbed by passing 5.0 mL of 1 M HNO3. The effects of analytical parameters, including pH of the solution, eluent type and volume, sample volume, flow rate of the eluent, and matrix ions, were investigated for optimization of the presented procedure. The enrichment factor was 180, and the LOD for Ni was 4.9 ng/L. The method was applied to the determination of Ni in water, food, and biological samples, and reproducible results were obtained.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 49 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Removal and recovery of nickel(II) from aqueous solution by loofa sponge-immobilized biomass of Chlorella sorokiniana:: characterization studies [J].
Akhtar, N ;
Iqbal, J ;
Iqbal, M .
JOURNAL OF HAZARDOUS MATERIALS, 2004, 108 (1-2) :85-94
[3]  
[Anonymous], 1995, ASTM DES 4638
[4]   A permeation liquid membrane system for determination of nickel in seawater [J].
Aouarram, A. ;
Galindo-Riano, M. D. ;
Garcia-Vargas, M. ;
Stitou, M. ;
El Yousfi, F. .
TALANTA, 2007, 71 (01) :165-170
[5]   Preconcentration, speciation and determination of ultra trace amounts of mercury by modified octadecyl silica membrane disk/electron beam irradiation and cold vapor atomic absorption spectrometry [J].
Ashkenani, Hamid ;
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji ;
Jaffari, Abbas Ali ;
Behjat, Abbas .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (01) :276-280
[6]   Application of a new ion-imprinted polymer for solid-phase extraction of bismuth from various samples and its determination by ETAAS [J].
Ashkenani, Hamid ;
Taher, Mohammad Ali .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (11) :1132-1145
[7]   Determination of cadmium(II) using carbon paste electrode modified with a Cd-ion imprinted polymer [J].
Ashkenani, Hamid ;
Taher, Mohammad Ali .
MICROCHIMICA ACTA, 2012, 178 (1-2) :53-60
[8]   Use of ionic liquid in simultaneous microextraction procedure for determination of gold and silver by ETAAS [J].
Ashkenani, Hamid ;
Taher, Mohammad Ali .
MICROCHEMICAL JOURNAL, 2012, 103 :185-190
[9]   Lead and nickel removal using Microspora and Lemna minor [J].
Axtell, NR ;
Sternberg, SPK ;
Claussen, K .
BIORESOURCE TECHNOLOGY, 2003, 89 (01) :41-48
[10]   Determination of lead and nickel in environmental samples by flame atomic absorption spectrometry after column solid-phase extraction on Ambersorb-572 with EDTA [J].
Baytak, S ;
Türker, AR .
JOURNAL OF HAZARDOUS MATERIALS, 2006, 129 (1-3) :130-136