Coordinator Traffic Diffusion for Data-Intensive Zigbee Transmission in Real-time Electrocardiography Monitoring

被引:16
作者
Tseng, Chinyang Henry [1 ]
机构
[1] Natl Taipei Univ, Dept Comp Sci & Informat Engn, Taipei 237, Taiwan
关键词
Coordinator; coordinator traffic diffusion (CTD); electrocardiography (ECG); end device (ED); router; sink; zigbee;
D O I
10.1109/TBME.2013.2266373
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Zigbee is expected to have an explosive growth in wireless medical monitoring systems because it possesses the advantages of low cost, safe power strength, and easy deployment. However, limited work focuses on solving the bottleneck issue at the Zigbee coordinator in a data-intensive system to guarantee transmission reliability of life-critical data. This paper proposes coordinator traffic diffusion (CTD) method to redirect excessive traffic from coordinator to the sink in electrocardiography (ECG) medical application. CTD router, which implements CTD design, automatically redirects ECG data traffic to the sink node without involving the coordinator, and thus reliable real-time ECG monitoring service can be delivered precisely. CTD design is tested in both TI CC2530 Zigbee platform and NS2 simulation. Experimental result demonstrates that a CTD design can assist routers in successfully delivering real-time ECG data samples reliably with the best transmission rate, 24 kb/s. This performance cannot be achieved by the original Zigbee design.
引用
收藏
页码:3340 / 3346
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 2011, P 2011 5 INT C APPL
[2]  
Cai K., 2010, 4 INT C BIOINF BIOM, P1
[3]   A Reliable Transmission Protocol for ZigBee-Based Wireless Patient Monitoring [J].
Chen, Shyr-Kuen ;
Kao, Tsair ;
Chan, Chia-Tai ;
Huang, Chih-Ning ;
Chiang, Chih-Yen ;
Lai, Chin-Yu ;
Tung, Tse-Hua ;
Wang, Pi-Chung .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (01) :6-16
[4]  
Ernest K., 2011, 2011 1st Middle East Conference on Biomedical Engineering (MECBME), P442, DOI 10.1109/MECBME.2011.5752159
[5]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[6]  
IEEE Computer Society, 2003, 802154 IEEE LANMAN S
[7]  
Kuei-Li Huang, 2011, Proceedings of the 2011 International Conference on Parallel Processing Workshops (ICPPW 2011), P1, DOI 10.1109/ICPPW.2011.20
[8]  
Lin W., 2011, P 8 INT C EXP EM TEC, P1
[9]   Dynamical model for generating synthetic electrocardiogram signals [J].
McSharry, PE ;
Clifford, GD ;
Tarassenko, L ;
Smith, LA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) :289-294
[10]   A rate distortion optimal ECG coding algorithm [J].
Nygaard, R ;
Melnikov, G ;
Katsaggelos, AK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (01) :28-40