Comparison of Bergeron and frequency-dependent cable models for the simulation of electromagnetic transients

被引:0
|
作者
da Silva, F. Faria [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
Electromagnetic Transients; Simulation and Modelling; HVAC cables; Bergeron Models; Frequency-dependent models;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The simulation of electromagnetic transients involving underground cables is very time consuming, when compared with simulations involving overhead lines, and Bergeron models are often used instead of the more accurate frequency-dependent models, in order to reduce the simulation time. This paper analyses the simulation errors of different Bergeron models to a reference frequency-dependent model for a 150kV cable. The simulations consider flat and trefoil installation, both-ends bonding and cross-bonding, ideal voltage source and modelling of the area around the cable. The Bergeron model is simulated for three different target frequencies: transient's resonance frequency, 50Hz and an in-between frequency. The results are analysed theoretically using modal propagation theory and the error is quantified for the case under examination. It is concluded that for a realistic case, which requires the modelling of the area around the cable being energised, the Bergeron model has a small error if tuned for the right frequency.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Wave Propagation Characteristics and Electromagnetic Transient Analysis of Underground Cable Systems Considering Frequency-Dependent Soil Properties
    Papadopoulos, Theofilos A.
    Datsios, Zacharias G.
    Chrysochos, Andreas I.
    Mikropoulos, Pantelis N.
    Papagiannis, Grigoris K.
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 259 - 267
  • [32] ANALYSIS OF TRANSIENTS IN FREQUENCY-DEPENDENT INTERCONNECTIONS AND PLANAR CIRCUITS WITH NONLINEAR LOADS
    GU, Q
    SHEEN, DM
    ALI, SM
    IEE PROCEEDINGS-H MICROWAVES ANTENNAS AND PROPAGATION, 1992, 139 (01) : 38 - 44
  • [33] Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages
    Marzinotto, Massimo
    Pelliccione, Giuseppe
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (02) : 115 - 122
  • [34] Frequency Characteristics of Fault Transients for HVDC Transmission Line with Frequency-dependent Distributed Parameters
    Wang Yafei
    Yu Yang
    Liu Shuli
    Hu Yuanchao
    Gao Tonghu
    Zhang Pengfeng
    Si Shukai
    Yu Hong
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [35] Z-domain frequency-dependent AC-system equivalent for electromagnetic transient simulation
    Wang, YP
    Watson, NR
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (02) : 141 - 146
  • [36] Full frequency-dependent line model for electromagnetic transient simulation including lumped and distributed sources
    Ramirez, A
    Naredo, L
    Moreno, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) : 292 - 299
  • [37] Frequency-Dependent Cohesive Zone Models for Fatigue
    Salih, S.
    Davey, K.
    Zou, Z.
    6TH INTERNATIONAL CONFERENCE ON FRACTURE FATIGUE AND WEAR (FFW), 2017, 843
  • [38] Validation of frequency-dependent transmission line models
    Gustavsen, B
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 925 - 933
  • [39] ON COMPARISON OF MODELS FOR SIMULATION OF TRANSIENTS IN A PWR PRESSURIZER
    MASSOUD, M
    MUNNO, FJ
    SIMULATORS VI, 1989, 21 : 160 - 163
  • [40] Statistical models and frequency-dependent corner models for passive devices
    Lu, Ning