Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

被引:36
作者
Takeuchi, Mitsuru [1 ]
Kawai, Tatsuya [1 ]
Ito, Masato [1 ]
Ogawa, Masaki [1 ]
Ohashi, Kazuya [2 ]
Hara, Masaki [1 ]
Shibamoto, Yuta [1 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Nagoya City Univ Hosp, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
Dual energy CT; CT urography; Virtual non-enhanced image; Radiation dose reduction; COMPUTED-TOMOGRAPHY; COLLECTING SYSTEM; MDCT UROGRAPHY; URINARY STONES; CONTRAST; OPTIMIZATION; ENHANCEMENT; PERFORMANCE; HEMATURIA; PHANTOM;
D O I
10.1016/j.ejrad.2012.05.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 +/- 15 [SD] and -16 +/- 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:3160 / 3165
页数:6
相关论文
共 19 条
  • [1] Split-bolus MDCT urography with synchronous nephrographic and excretory phase enhancement
    Chow, Lawrence C.
    Kwan, Sharon W.
    Olcott, Eric W.
    Sommer, Graham
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) : 314 - 322
  • [2] Optimization of Computed Tomography Urography Protocol, 1997 to 2008: Effects on Radiation Dose
    Dahlman, P.
    Jangland, L.
    Segelsjo, M.
    Magnusson, A.
    [J]. ACTA RADIOLOGICA, 2009, 50 (04) : 446 - 454
  • [3] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [4] Dual energy CT: preliminary observations and potential clinical applications in the abdomen
    Graser, Anno
    Johnson, Thorsten R. C.
    Chandarana, Hersh
    Macari, Michael
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (01) : 13 - 23
  • [5] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    [J]. RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [6] Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies
    Kawai, Tatsuya
    Shibamoto, Yuta
    Hara, Masaki
    Arakawa, Toshinao
    Nagai, Keiichi
    Ohashi, Kazuya
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (06) : 682 - 689
  • [7] CT urography
    Kawashima, A
    Vrtiska, TJ
    LeRoy, AJ
    Hartman, RP
    McCollough, CH
    King, BF
    [J]. RADIOGRAPHICS, 2004, 24 : S35 - S54
  • [8] Performance of Dual-Energy CT with Tin Filter Technology for the Discrimination of Renal Cysts and Enhancing Masses
    Leschka, Sebastian
    Stolzmann, Paul
    Baumueller, Stephan
    Scheffel, Hans
    Desbiolles, Lotus
    Schmid, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (04) : 526 - 534
  • [9] Multidetector CT urography in imaging of the urinary tract in patients with hematuria
    Maher, MM
    Kalra, MK
    Rizzo, S
    Mueller, PR
    Saini, S
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (01) : 1 - 10
  • [10] Multi-detector row CT urography: Comparison of strategies for depicting the normal urinary collecting system
    McTavish, JD
    Jinzaki, M
    Zou, KH
    Nawfel, RD
    Silverman, SG
    [J]. RADIOLOGY, 2002, 225 (03) : 783 - 790