Comparison of arthroscopic meniscal repair results using 3 different meniscal repair devices in anterior cruciate ligament reconstruction patients

被引:90
作者
Kalliakmanis, Alkiviadis [1 ]
Zoumtos, Sarantos [1 ]
Bousgas, Dimitrios [1 ]
Nikolaou, Pantelis [1 ]
机构
[1] Med Ctr, Dept Sports Med, Athens, Greece
关键词
meniscal repair; all-inside meniscal implants; clinical results;
D O I
10.1016/j.arthro.2008.03.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The goal of this study was the clinical evaluation of arthroscopic meniscal repair results with the use of 3 different repair devices. Methods: From 2001 to 2006, 265 patients underwent 280 meniscal repairs (RapidLoc [DePuy Mitek, Raynham, MA] in 88 patients, T-Fix [Acufex Microsurgical, Mansfield, MA] in 85 patients, and FasT-Fix [Smith & Nephew Endoscopy, Andover, MA] in 92 patients). There were 181 medial and 99 lateral tears; 174 tears were located in Cooper radial zone 1, and 106 tears were in Cooper radial zone 2. All patients had associated anterior cruciate ligament reconstructions. Follow-up assessment included clinical examination, arthrometry (KT-1000; MEDmetric, San Diego, CA), International Knee Documentation Committee scores, and scores on Lysholm functional questionnaires. Clinical criteria for a successful result included the absence of joint line tenderness, swelling, and blocking and the presence of a negative McMurray test. Results: The mean follow-up was 24.5 months (range, 20 to 26 months). Tear length averaged 3.17 cm (range, 1.4 to 4 cm). A mean of 2.4 suture devices was used. On the basis of our criteria, 28 meniscus repairs were considered to be failures (success rates of 92.4% for FasT-Fix, 87% for T-Fix, and 86.5% for RapidLoc). There were 16 relook arthroscopies for device removal and partial meniscectomy, with I I patients (68.7%) having failure of the meniscal repair in zone 2. Both the Lysholm and International Knee Documentation Committee scores were significantly improved. Chronicity or location of the tear, length of the tear, and patient age did not affect the clinical outcome. Conclusions: The compared meniscal repair systems showed comparable clinical results. These meniscal repair systems appeared to be safe and effective, providing a high rate of meniscal healing both in patients with complex tears and in patients with tears located in Cooper radial zone 2. Level of Evidence: Level III, therapeutic retrospective comparative study.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 33 条
[1]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[2]   The arrow versus horizontal suture in arthroscopic meniscus repair - A prospective randomized study with arthroscopic evaluation [J].
Albrecht-Olsen, P ;
Kristensen, G ;
Burgaard, P ;
Joergensen, U ;
Toerholm, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (05) :268-273
[3]  
Annandale T, 1885, Br Med J, V1, P779
[4]  
Arnoczky SP, 1993, SURG KNEE, P21
[5]   Failure strength of repair devices versus meniscus suturing techniques [J].
Asik, M ;
Sener, N .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (01) :25-29
[6]   Arthroscopic meniscal repair using T-fix [J].
Asik, M ;
Sen, C ;
Erginsu, M .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (05) :284-288
[7]   MENISCAL TEARS - THE EFFECT OF MENISCECTOMY AND OF REPAIR ON INTRAARTICULAR CONTACT AREAS AND STRESS IN THE HUMAN KNEE - A PRELIMINARY-REPORT [J].
BARATZ, ME ;
FU, FH ;
MENGATO, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (04) :270-275
[8]   Meniscal repair with the RapidLoc meniscal repair device [J].
Barber, F. Alan ;
Coons, David A. ;
Ruiz-Suarez, Michell .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (09) :962-966
[9]   Load to failure testing of new meniscal repair devices [J].
Barber, FA ;
Herbert, MA ;
Richards, DP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (01) :45-50
[10]   Meniscal repair devices [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 2000, 16 (06) :613-618