Development and comparison of residual stress measurement on welds by various methods

被引:44
作者
Bahadur, A [1 ]
Kumar, BR
Kumar, AS
Sarkar, GG
Rao, JS
机构
[1] Natl Met Lab, Jamshedpur 831007, Bihar, India
[2] MECON, Ranchi, Bihar, India
关键词
welding; steels; residual stress measurement;
D O I
10.1179/026708304225012332
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Residual stress constitutes an integral part of the total stress acting on any component in service. It is imperative to determine residual stress to estimate the life of critical engineering components, especially those that are welded. The stresses caused by non-uniform temperature distribution due to welding and the effect of these multiaxial stresses upon service performance are discussed. A controlled thermal severity test (CTS) was performed on mild steel plates bolted together, with anchor welds deposited on opposite sides. After cooling, bithermal and trithermal test welds were deposited one after the other. Varying welding stresses were deliberately introduced by using different thicknesses of both plates to change the thermal severity numbers (TSN). The main experimental technique used here to determine the magnitude and nature of residual stress is based on X-ray diffraction (XRD). It was utilised to develop and standardise other techniques. The XRD method is based on the peak shift in the diffraction profile due to the presence of stress using a sin(2)psi method. The peak shift is determined by orienting the sample at different angles +/-psi to the incident X-ray beam. The semidestructive technique of hole drilling and use of a strain gauge was also employed to determine residual stress in CTS specimens. The magnitude, nature, and direction of principal stresses were determined by relieving stresses through incremental blind hole drilling and measuring strain values at each step. The surface displacements arising due to hole drilling can also be determined by laser holography. A sandwich holography technique was developed to avoid unwanted rigid body motions of samples due to hole drilling when relieving stresses. Stress values were obtained by measuring fringe displacement between two exposures of a sandwich hologram, due to hole drilling. Results on the change in residual stress values with TSN are discussed. The residual stress values determined by XRD and sandwich holography were found to be comparable, and stress values obtained by hole drilling/strain gauge measurement were higher than these values. The reasons are discussed.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 24 条
[1]   SANDWICH HOLOGRAM INTERFEROMETRY - NEW DIMENSION IN HOLOGRAPHIC COMPARISON [J].
ABRAMSON, N .
APPLIED OPTICS, 1974, 13 (09) :2019-2025
[2]   SANDWICH HOLOGRAM INTERFEROMETRY .2. SOME PRACTICAL CALCULATIONS [J].
ABRAMSON, N .
APPLIED OPTICS, 1975, 14 (04) :981-984
[3]  
ABRAMSON N, 2001, MAKING EVALUATION HO
[4]  
ALLEN LB, 1960, P SOC PHOTO-OPT INS, P713
[5]  
*ASTM, 1992, 83792 ASTM E
[6]  
Bathgate R. G., 1968, Strain, V4, P20, DOI 10.1111/j.1475-1305.1968.tb01353.x
[7]  
BEANEY IM, 1976, STRAIN, V99, P106
[8]  
Chandler H., 1995, Heat Treater's Guide, Practices and Procedures for Irons and Steels, V2nd
[9]  
CHIANG FP, 1983, J MET MAY, P49
[10]  
ESQUIVEL AL, 1969, ADV XRAY ANAL, V12, P269