A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations

被引:89
作者
Longmore, Sally K. [1 ]
Lui, Gough Y. [1 ]
Naik, Ganesh [1 ]
Breen, Paul P. [1 ,2 ]
Jalaludin, Bin [3 ,4 ]
Gargiulo, Gaetano D. [1 ,2 ]
机构
[1] Western Sydney Univ, MARCS Inst Brain Behav & Dev, Milperra, NSW 2560, Australia
[2] Western Sydney Univ, Translat Hlth Res Inst, Campbelltown, NSW 2560, Australia
[3] Univ New South Wales, Ingham Inst Appl Med Res, Liverpool, NSW 2052, Australia
[4] Ctr Air Pollut Energy & Hlth Res CAR, Glebe, NSW 2037, Australia
关键词
photoplethysmography; heart rate; SpO(2); respiration rate; anatomical location; PULSE OXIMETRY; VOLUMES; SIGNAL;
D O I
10.3390/s19081874
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring of vital signs is critical for patient triage and management. Principal assessments of patient conditions include respiratory rate heart/pulse rate and blood oxygen saturation. However, these assessments are usually carried out with multiple sensors placed in different body locations. The aim of this paper is to identify a single location on the human anatomy whereby a single 1 cm x 1 cm non-invasive sensor could simultaneously measure heart rate (HR), blood oxygen saturation (SpO(2)), and respiration rate (RR), at rest and while walking. To evaluate the best anatomical location, we analytically compared eight anatomical locations for photoplethysmography (PPG) sensors simultaneously acquired by a single microprocessor at rest and while walking, with a comparison to a commercial pulse oximeter and respiration rate ground truth. Our results show that the forehead produced the most accurate results for HR and SpO(2) both at rest and walking, however, it had poor RR results. The finger recorded similar results for HR and SpO(2), however, it had more accurate RR results. Overall, we found the finger to be the best location for measurement of all three parameters at rest; however, no site was identified as capable of measuring all parameters while walking.
引用
收藏
页数:19
相关论文
共 30 条
[1]   Pulse oximetry-derived respiratory rate in general care floor patients [J].
Addison, Paul S. ;
Watson, James N. ;
Mestek, Michael L. ;
Ochs, James P. ;
Uribe, Alberto A. ;
Bergese, Sergio D. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) :113-120
[2]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[3]   Estimation of the spectral absorption of light by components of human skin [J].
Barun, V. V. ;
Ivanov, A. P. .
OPTICS AND SPECTROSCOPY, 2009, 106 (01) :84-91
[4]   Pulse Oximetry in Emergency Medicine [J].
Callahan, James M. .
EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2008, 26 (04) :869-+
[5]   Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations [J].
Chan, Edward D. ;
Chan, Michael M. ;
Chan, Mallory M. .
RESPIRATORY MEDICINE, 2013, 107 (06) :789-799
[6]   FOREHEAD PULSE OXIMETRY COMPARED WITH FINGER PULSE OXIMETRY AND ARTERIAL BLOOD-GAS MEASUREMENT [J].
CHENG, EY ;
HOPWOOD, MB ;
KAY, J .
JOURNAL OF CLINICAL MONITORING, 1988, 4 (03) :223-226
[7]   A Wearable Contactless Sensor Suitable for Continuous Simultaneous Monitoring of Respiration and Cardiac Activity [J].
Gargiulo, Gaetano D. ;
Gunawardana, Upul ;
O'Loughlin, Aiden ;
Sadozai, Mohammad ;
Varaki, Elham Shabani ;
Breen, Paul P. .
JOURNAL OF SENSORS, 2015, 2015
[8]   Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study [J].
Gargiulo, Gaetano D. ;
O'Loughlin, Aiden ;
Breen, Paul P. .
PHYSIOLOGICAL MEASUREMENT, 2015, 36 (02) :N35-N49
[9]   Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients [J].
Grubb, M. R. ;
Carpenter, J. ;
Crowe, J. A. ;
Teoh, J. ;
Marlow, N. ;
Ward, C. ;
Mann, C. ;
Sharkey, D. ;
Hayes-Gill, B. R. .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) :881-893
[10]   Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor [J].
Harju, Jarkko ;
Vehkaoja, Antti ;
Lindroos, Ville ;
Kumpulainen, Pekka ;
Liuhanen, Sasu ;
Yli-Hankala, Arvi ;
Oksala, Niku .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) :1019-1026