The rotator cuff functional index

被引:8
作者
Osbahr, Daryl C.
Murrell, George A. C.
机构
[1] Univ New S Wales, Dept Orthopaed Surg, Sydney, NSW 2217, Australia
[2] Univ N Carolina, Sch Med, Chapel Hill, NC USA
关键词
rotator cuff; shoulder; handheld dynamometer; shoulder strength;
D O I
10.1177/0363546505284847
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Despite improvements in the clinical assessment of rotator cuff injuries, shortcomings exist in diagnosing rotator cuff tears. Purpose: To formulate a clinical rotator cuff functional index for predicting rotator cuff tears based on handheld dynamometer measurements for shoulder strength testing and to assess its ability to diagnose a rotator cuff tear. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Preoperative handheld dynamometer measurements, including supraspinatus, external rotation, internal rotation, addluction, and lift-off force, were compared in 100 patients with full-thickness rotator cuff tears (> 1.0 cm) and 100 patients with no rotator cuff injury (confirmed by arthroscopy). Using multiple logistic regression analysis, the rotator cuff functional index and index for rotator cuff tear size were formulated in which 100 represented excellent rotator cuff function and less than 0 indicated a full-thickness supraspinatus tear. Each patient's index was calculated to determine its clinical value in predicting a rotator cuff tear; the Pearson correlation coefficient was established for the rotator cuff functional index for rotator cuff size. Results: Two handheld dynamometer measurements predicted a rotator cuff tear (P <.001, r = 0.53), with rotator cuff functional index = 1.27 * supraspinatus (N) - 0.72 * adcluction (N) - 11.6, but not tear size (r = 0.38). In predicting a rotator cuff tear (rotator cuff functional index < 0 = rotator cuff tear; rotator cuff functional index > 0 = no tear), the rotator cuff functional index had 83% sensitivity, 79% specificity, 80% positive predictive value, 82% negative predictive value, likelihood ratio of 4.0 for a positive test result and 0.2 for a negative test result and an accuracy of 81%. Conclusion: The 2 most useful tests for determining a rotator cuff tear with a handheld dynamometer were supraspinatus force and adcluction force (as negative control). A functional index based on these measurements was able to rule out a rotator cuff tear and predict the presence but not the size of the tear.
引用
收藏
页码:956 / 960
页数:5
相关论文
共 25 条
[1]   RELATIONSHIP OF MANUAL MUSCLE TESTING TO OBJECTIVE STRENGTH MEASUREMENTS [J].
AITKENS, S ;
LORD, J ;
BERNAUER, E ;
FOWLER, WM ;
LIEBERMAN, JS ;
BERCK, P .
MUSCLE & NERVE, 1989, 12 (03) :173-177
[2]  
BARTOLOZZI A, 1994, CLIN ORTHOP RELAT R, P90
[3]  
BEASLEY W C, 1956, Phys Ther Rev, V36, P21
[4]  
Bohannon R.W., 1990, CRIT REV PHYS MED RE, V2, P75
[5]   MAKE TESTS AND BREAK TESTS OF ELBOW FLEXOR MUSCLE STRENGTH [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1988, 68 (02) :193-194
[6]   Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years [J].
Bohannon, RW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01) :26-32
[7]   INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[8]   TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[9]   ISOLATED RUPTURE OF THE TENDON OF THE SUBSCAPULARIS MUSCLE - CLINICAL-FEATURES IN 16 CASES [J].
GERBER, C ;
KRUSHELL, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (03) :389-394
[10]   Reliability of 3 methods for assessing shoulder strength [J].
Hayes, K ;
Walton, JR ;
Szomor, ZL ;
Murrell, GAC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (01) :33-39