RETRACTED: Investigation on Imaging Features and Clinical Significance of Cardiac CT in Comprehensive Evaluation of Aortic Valve and Root before Percutaneous Aortic Valve Replacement (Retracted Article)

被引:1
作者
Tan, Xiong [1 ]
Peng, Juan [2 ]
机构
[1] North Sichuan Med Coll, Dept Cardiothorac Surg, Affiliated Hosp, Nanchong 637000, Sichuan, Peoples R China
[2] Kunming Med Univ, Dept Ultrasound, Affiliated Hosp 1, Kunming 650032, Yunnan, Peoples R China
关键词
TRANSCATHETER; DEVICE;
D O I
10.1155/2022/5838670
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Medical imaging feature analysis is the basis of medical image processing and analysis. The solution of this problem not only directly affects the successful application of computer graphics and image technology in medicine but also has important theoretical and practical significance. In this paper, the imaging characteristics and clinical significance are discussed by studying the comprehensive evaluation of aortic valve and root before aortic valve replacement. In recent years, preoperative comprehensive evaluation of the aortic valve and root has been gradually carried out. Compared with traditional methods, minimally invasive surgery brings more accurate diagnosis to patients, quick recovery and discharge after surgery, and less pain. This study retrospectively includes patients with severe aortic stenosis who underwent TAVR with routine computed tomography. Based on CT images, the determination and grouping of bicuspid aortic valve and tricuspid aortic valve were completed. Thirteen cross-sectional levels of the aorta-iliac-femoral vascular access were completed. The results showed that 3 people had stroke (17.6%) and 5 people had myocardial infarction (29.4%) during the follow-up period. Atrial fibrillation occurred in 5 patients (29.4%), permanent pacemaker implantation was performed in 1 patient (5.9%), and acute kidney injury occurred in 7 patients (41.2%). No patient died due to surgery-related causes, and the analysis of imaging features and clinical significance in the preoperative comprehensive evaluation of the aortic valve and root played a crucial role. In the training stage, the principal component analysis method was used to train the shape, and the model of the shape intensity of the aortic valve and the shape change of each principal component was obtained. The most probable aortic valve region in the target image was obtained by matching the similarity of all atlases, and the correct aortic valve segmentation was obtained by using the first level set of shape intensity. The experimental part verified the accuracy of the algorithm.
引用
收藏
页数:12
相关论文
共 18 条
[1]   Radiofrequency Ablation of Lung Tumors: Imaging Features of the Post-ablation Zone [J].
Abtin, Fereidoun G. ;
Eradat, Jilbert ;
Gutierrez, Antonio J. ;
Lee, Christopher ;
Fishbein, Michael C. ;
Suh, Robert D. .
RADIOGRAPHICS, 2012, 32 (04) :947-+
[2]   Transcatheter Aortic Valve Replacement: A Review [J].
Braxton, John H. ;
Rasmussen, Kelly S. ;
Shah, Milind S. .
SURGICAL CLINICS OF NORTH AMERICA, 2017, 97 (04) :899-+
[3]   REPLY: Transcatheter Versus Surgical Aortic Valve Replacement Unneglectable Concomitant Coronary Artery Disease [J].
Brennan, J. Matthew .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (01) :106-107
[4]   Transcatheter Versus Surgical Aortic Valve Replacement Propensity-Matched Comparison [J].
Brennan, J. Matthew ;
Thomas, Laine ;
Cohen, David J. ;
Shahian, David ;
Wang, Alice ;
Mack, Michael J. ;
Holmes, David R. ;
Edwards, Fred H. ;
Frankel, Naftali Z. ;
Baron, Suzanne J. ;
Carroll, John ;
Thourani, Vinod ;
Tuzcu, E. Murat ;
Arnold, Suzanne V. ;
Cohn, Roberta ;
Maser, Todd ;
Schawe, Brenda ;
Strong, Susan ;
Stickfort, Allen ;
Patrick-Lake, Elizabeth ;
Graham, Felicia L. ;
Dai, Dadi ;
Li, Fan ;
Matsouaka, Roland A. ;
O'Brien, Sean ;
Li, Fan ;
Pencina, Michael J. ;
Peterson, Eric D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (04) :439-450
[5]   Comprehensive Right-Sided Assessment for Transcatheter Aortic Valve Replacement Risk Stratification: Time for a Change [J].
Cavalcante, Joao L. ;
Simon, Marc A. ;
Chan, Stephen Y. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) :47-51
[6]   Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience [J].
Dranishnikov, Nikolay ;
Stepanenko, Alexander ;
Potapov, Evgenij V. ;
Dandel, Michael ;
Siniawski, Henryk ;
Mladenow, Alexander ;
Huebler, Michael ;
Grauhan, Onnen ;
Weng, Yuguo ;
Krabatsch, Thomas ;
Hetzer, Roland ;
Kukucka, Marian .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2012, 35 (07) :489-494
[7]   Trends in aortic valve replacement in Germany in 2015: transcatheter versus isolated surgical aortic valve repair [J].
Gaede, Luise ;
Blumenstein, Johannes ;
Kim, Won-Keun ;
Liebetrau, Christoph ;
Doerr, Oliver ;
Nef, Holger ;
Hamm, Christian ;
Elsaesser, Albrecht ;
Moellmann, Helge .
CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (06) :411-419
[8]   Changes in myocardial deformation after transcatheter and surgical aortic valve replacement [J].
Garg, Vinisha ;
Ho, Jonathan K. ;
Vorobiof, Gabriel .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (04) :603-613
[9]   Predictive factor of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis: the importance of myocardial hypertrophy and diastolic dysfunction [J].
Igarashi, Takashi ;
Tanji, Masahiro ;
Takahashi, Koki ;
Ishida, Keiichi ;
Sasaki, Satomi ;
Yokoyama, Hitoshi .
GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (05) :259-266
[10]   Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement Incidence, Characteristics, and Treatment Outcomes [J].
Jose, John ;
Sulimov, Dmitriy S. ;
El-Mawardy, Mohamed ;
Sato, Takao ;
Allali, Abdelhakim ;
Holy, Erik W. ;
Becker, Bjorn ;
Landt, Martin ;
Kebernik, Julia ;
Schwarz, Bettina ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07) :686-697