Comparison of anterior cervical discectomy and fusion with the zero-profile implant and cage-plate implant in treating two-level degenerative cervical spondylosis

被引:0
|
作者
Yang, Yi [1 ]
Ma, Litai [1 ]
Zeng, Junfeng [1 ]
Liu, Hao [1 ]
Hong, Ying [2 ]
Wang, Beiyu [1 ]
Ding, Chen [1 ]
Deng, Yuxiao [1 ]
Song, Yueming [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthoped, 37 Guoxuexiang, Chengdu 610041, Sichuan Provinc, Peoples R China
[2] Sichuan Univ, West China Hosp, Operat Room, Chengdu, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2016年 / 9卷 / 11期
关键词
ACDF; Zero-P; degenerative cervical spondylosis; plate; anterior cervical discectomy and fusion; ANCHORED SPACER; INTERBODY FUSION; SPINE SURGERY; DYSPHAGIA; METAANALYSIS; ACDF; DEVICE; RATES;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Previous studies based on small sample sizes have reported the application of the Zero-P implant (Zero-P, Synthes GmbH, Switzerland) in single anterior cervical discectomy and fusion (ACDF) surgery with excellent outcomes. However, the safety and effectiveness of two-level ACDF with Zero-P implant still remains controversial. A retrospective study was conducted to compare the clinical outcomes and complications between Zero-P implant and conventional cage-plate implant in two-level ACDF for the treatment of degenerative cervical spondylosis. The Japanese Orthopedic Association (JOA) scale score, neck and arm visual analog scale (VAS), bony fusion rates and main complications were recorded. Dysphagia was evaluated according to the Bazaz grading system. A total of 67 consecutive patients in Zero-P group and 72 consecutive patients in Plate group were enrolled in this retrospective study. The total incidence of dysphagia in Zero-P group and Plate group were 40.00% and 55.56% at one week, respectively. Similar improvements were observed in the JOA and VAS pain scores in both groups at the final follow-up (P>0.05). There were no significant difference between two groups concerning other complications such as postoperative hematoma, recurrent laryngeal nerve palsy, cerebrospinal fluid leakage and pseudarthrosis. The Zero-P implant and the traditional titanium plate with cage are both effective treatments for two-level degenerative cervical spondylosis, but the Zero-P implant has a lower dysphagia incidence. Future prospective, randomized and controlled studies with larger sample size are needed.
引用
收藏
页码:21772 / 21779
页数:8
相关论文
共 50 条
  • [31] Early Follow-Up Outcomes of a New Zero-profile Implant Used in Anterior Cervical Discectomy and Fusion
    Miao, Jinhao
    Shen, Ye
    Kuang, Yong
    Yang, Lili
    Wang, Xinwei
    Chen, Yu
    Chen, Deyu
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (05): : E193 - E197
  • [32] Zero-Profile Versus Cage and Plate in Anterior Cervical Discectomy and Fusion with a Minimum 2 Years of Follow-Up: A Meta-Analysis
    Sun, Zhicheng
    Liu, Zheng
    Hu, Wenkai
    Yang, Yan
    Xiao, Xiao
    Wang, Xiyang
    WORLD NEUROSURGERY, 2018, 120 : E551 - E561
  • [33] The application of zero-profile anchored spacer in anterior cervical discectomy and fusion
    Wang, Zhiwen
    Jiang, Weimin
    Li, Xuefeng
    Wang, Heng
    Shi, Jinhui
    Chen, Jie
    Meng, Bin
    Yang, Huilin
    EUROPEAN SPINE JOURNAL, 2015, 24 (01) : 148 - 154
  • [34] Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
    Wang, Yang
    Liu, Yang
    Zhang, Aobo
    Han, Qing
    Jiao, Jianhang
    Chen, Hao
    Gong, Xuqiang
    Luo, Wangwang
    Yue, Jing
    Zhao, Xue
    Wang, Jincheng
    Wu, Minfei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [35] Anterior cervical discectomy and fusion with a zero-profile integrated plate and spacer device: a clinical and radiological study
    Njoku, Innocent, Jr.
    Alimi, Marjan
    Leng, Lewis Z.
    Shin, Benjamin J.
    James, Andrew R.
    Bhangoo, Sandeep
    Tsiouris, Apostolos John
    Haertl, Roger
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 21 (04) : 529 - 537
  • [36] Cervical Vertebral Bone Quality Score Independently Predicts Zero-Profile Cage Subsidence After Single-Level Anterior Cervical Discectomy and Fusion
    Wang, Zhe
    Huang, Yong
    Chen, Qian
    Liu, Limin
    Song, Yueming
    Feng, Ganjun
    WORLD NEUROSURGERY, 2024, 182 : E377 - E385
  • [37] Meta-Analysis Comparing Zero-Profile Spacer and Anterior Plate in Anterior Cervical Fusion
    Dong, Jun
    Lu, Meng
    Lu, Teng
    Liang, Baobao
    Xu, Junkui
    Zhou, Jun
    Lv, Hongjun
    Qin, Jie
    Cai, Xuan
    Huang, Sihua
    Li, Haopeng
    Wang, Dong
    He, Xijing
    PLOS ONE, 2015, 10 (06):
  • [38] Comparison of the Postoperative Motion Stabilization Between Anterior Cervical Decompression and Fusion with a Zero-Profile Implant System and a Plate-Cage Construct
    Abudouaini, Haimiti
    Wu, Tingkui
    Liu, Hao
    Wang, Beiyu
    Chen, Hua
    Li, Lijun
    WORLD NEUROSURGERY, 2022, 166 : e484 - e494
  • [39] Anterior Cervical Discectomy and Fusion (ACDF): Comparison Between Zero Profile Implants and Anterior Cervical Plate and Spacer
    Alimi, Marjan
    Njoku, Innocent
    Hofstetter, Christoph P.
    Tsiouris, Apostolos J.
    Kesavabhotla, Kartik
    Boockvar, John
    Navarro-Ramirez, Rodrigo
    Hartl, Roger
    CUREUS, 2016, 8 (04):
  • [40] Plate augmentation in anterior cervical discectomy and fusion with cage for degenerative cervical spinal disorders
    Song, Kyung-Jin
    Taghavi, Cyrus E.
    Hsu, Margaret S.
    Lee, Kwang-Bok
    Kim, Gyu-Hyung
    Song, Ji-Hoon
    EUROPEAN SPINE JOURNAL, 2010, 19 (10) : 1677 - 1683