The airborne transmission of infection between flats in high-rise residential buildings: Particle simulation

被引:80
|
作者
Gao, N. P. [1 ]
Niu, J. L. [1 ]
Perino, M. [2 ]
Heiselberg, P. [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Politecn Torino, DENER, I-10129 Turin, Italy
[3] Aalborg Univ, Hybrid Ventilat Ctr, DK-9000 Aalborg, Denmark
关键词
Particles; Lagrangian method; Eulerian method; Transport; Deposition; LARGE-EDDY SIMULATION; NUMERICAL-SIMULATION; INDOOR ENVIRONMENTS; AEROSOL DEPOSITION; INFLUENZA-A; AIR-FLOW; DISPERSION; TRANSPORT; DROPLETS;
D O I
10.1016/j.buildenv.2008.03.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Several case clusters occurred in high-rise residential buildings in Hong Kong in the 2003 SARS (the severe acute respiratory syndrome) epidemic, which motivated a series of engineering investigations into the possible airborne transport routes. It is suspected that, driven by buoyancy force, the polluted air that exits the window of the lower floor may re-enter the immediate upper floor through the window on the same side. This cascade effect has been quantified and reported in a previous paper, and it is found that, by tracer gas concentration analysis, the room in the adjacent upstairs may contain up to 7% of the air directly from the downstairs room. In this study, after validation against the experimental data from literatures, Eulerian and Lagrangian approaches are both adopted to numerically investigate the dispersion of expiratory aerosols between two vertically adjacent flats. It is found that the particle concentration in the upper floor is two to three orders of magnitude lower than in the source floor. 1.0 mu m particles disperse like gaseous pollutants. For coarse particles larger than 20.0 mu m, strong deposition on solid surfaces and gravitational settling effect greatly limit their upward transport. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:402 / 410
页数:9
相关论文
共 50 条
  • [41] NUMERICAL SIMULATION OF 3D STEADY ATMOSPHERIC FLOW AROUND HIGH-RISE BUILDINGS
    Nie, Shao-Feng
    Zhou, Xu-Hong
    Zhou, Tian-Hua
    Gong, Xin
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1532 - 1537
  • [42] The simulation of airborne disease virus transmission in group buildings
    Xueyi You
    Chinese Journal of Geochemistry, 2006, 25 (Suppl 1): : 111 - 111
  • [43] The simulation of airborne disease virus transmission in group buildings
    Xueyi YOU Department of Environmental Science
    Acta Geochimica, 2006, (S1) : 111 - 111
  • [44] Assessment of pedestrian level wind environment of a group of high-rise buildings based on numerical simulation
    Quan, Yong
    Wang, Shuo
    Gu, Ming
    Zheng, Deqian
    Zhang, Aishe
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1553 - 1559
  • [45] Large-eddy simulation of vortex streets and pollutant dispersion behind high-rise buildings
    Han, Beom-Soon
    Park, Seung-Bu
    Baik, Jong-Jin
    Park, Junho
    Kwak, Kyung-Hwan
    QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 2017, 143 (708) : 2714 - 2726
  • [46] EVALUATION OF WIND ENVIRONMENT AROUND URBAN HIGH-RISE BUILDINGS
    Jiang, Youdi
    Zhu, Weifeng
    Chen, Jianping
    Ye, Qian
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 346 - 353
  • [47] On-site measurement of tracer gas transmission between horizontal adjacent flats in residential building and cross-infection risk assessment
    Wu, Yan
    Tung, Thomas C. W.
    Niu, Jian-lei
    BUILDING AND ENVIRONMENT, 2016, 99 : 13 - 21
  • [48] Large Eddy Simulation Investigation of Wind Loads and Interference Effects on Ultra High-rise Connecting Buildings
    Ke S.
    Wang H.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2017, 44 (05): : 53 - 62
  • [49] Study on Numerical Simulation of Smoke Control Mode in Smoke-proof Staircase of High-rise Buildings
    Li Decheng
    Liu Zegong
    2014 7TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA), 2014, : 705 - 712
  • [50] Research on numerical simulation of wind load on high-rise buildings along the street based on BIM model
    Mo, Lianguang
    Lu, Wenying
    INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2025, 16 (01)