Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique

被引:25
作者
Tocci, Stephen L. [1 ]
Tashjian, Robert Z. [4 ]
Leventhal, Evan [2 ]
Spenciner, David B. [2 ]
Green, Andrew [1 ,3 ]
Fleming, Braden C. [2 ]
机构
[1] Brown Med Sch, Dept Orthopaed Surg, Providence, RI 02912 USA
[2] Brown Med Sch, Bioengn Lab, Providence, RI 02912 USA
[3] Univ Orthoped Inc, Providence, RI USA
[4] Univ Utah, Orthopaed Ctr, Salt Lake City, UT USA
关键词
D O I
10.1016/j.jse.2008.02.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears foiled in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.
引用
收藏
页码:808 / 814
页数:7
相关论文
共 34 条
[1]   The relationship of suture anchor failure and bone density to proximal humerus location: A cadaveric study [J].
Barber, FA ;
Feder, SM ;
Burkhart, SS ;
Ahrens, J .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1997, 13 (03) :340-345
[2]   Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study [J].
Bishop, Julie ;
Klepps, Steven ;
Lo, Ian K. ;
Bird, Justin ;
Gladstone, James N. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) :290-299
[3]   Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[4]   Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation [J].
Burkhart, SS ;
Pagan, JLD ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (06) :720-724
[5]   Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[6]   Arthroscopic rotator cuff repair [J].
Burkhart, SS ;
Lo, IKY .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (06) :333-346
[7]   Tissue fixation security in transosseous rotator cuff repairs: A mechanical comparison of simple versus mattress sutures [J].
Burkhart, SS ;
Fischer, SP ;
Nottage, WM ;
Esch, JC ;
Barber, FA ;
Doctor, D ;
Ferrier, J .
ARTHROSCOPY, 1996, 12 (06) :704-708
[8]  
CHHABRA A, 2005, ARTHROSCOPY, V21
[9]   Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears - A randomized controlled trial [J].
Franceschi, Francesco ;
Ruzzini, Laura ;
Longo, Umile Giuseppe ;
Martina, Francesca Maria ;
Zobel, Bruno Beornonte ;
Maffulli, Nicola ;
Denaro, Vincenzo .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (08) :1254-1260
[10]   The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears [J].
Galatz, LM ;
Ball, CM ;
Teefey, SA ;
Middleton, WD ;
Yamaguchi, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) :219-224