Liquid crystal electro-optical transducers for electrophysiology sensing applications

被引:8
作者
Al Abed, Amr [1 ]
Wei, Yuan [1 ,2 ]
Almasri, Reem M. [1 ]
Lei, Xinyue [2 ]
Wang, Han [1 ]
Firth, Josiah [3 ]
Chen, Yingge [2 ]
Gouailhardou, Nathalie [1 ,4 ]
Silvestri, Leonardo [2 ]
Lehmann, Torsten [2 ]
Ladouceur, Francois [2 ]
Lovell, Nigel H. [1 ,5 ]
机构
[1] UNSW, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[2] UNSW, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[3] UNSW, Australian Natl Fabricat Facil, Sydney, NSW 2052, Australia
[4] UNSW, Sch Med Sci, Sydney, NSW 2052, Australia
[5] UNSW, Tyree Inst Heath Engn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会; 英国医学研究理事会;
关键词
optrode; sensor; optical interfaces; liquid crystal; OPTICAL MEASUREMENT; OPTRODE; VOLTAGE; TECHNOLOGIES; RECORDINGS;
D O I
10.1088/1741-2552/ac8ed6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Biomedical instrumentation and clinical systems for electrophysiology rely on electrodes and wires for sensing and transmission of bioelectric signals. However, this electronic approach constrains bandwidth, signal conditioning circuit designs, and the number of channels in invasive or miniature devices. This paper demonstrates an alternative approach using light to sense and transmit the electrophysiological signals. Approach. We develop a sensing, passive, fluorophore-free optrode based on the birefringence property of liquid crystals (LCs) operating at the microscale. Main results. We show that these optrodes can have the appropriate linearity (mu +/- s.d.: 99.4 +/- 0.5%, n = 11 devices), relative responsivity (mu +/- s.d.: 57 +/- 12%V-1, n = 5 devices), and bandwidth (mu +/- s.d.: 11.1 +/- 0.7 kHz, n = 7 devices) for transducing electrophysiology signals into the optical domain. We report capture of rabbit cardiac sinoatrial electrograms and stimulus-evoked compound action potentials from the rabbit sciatic nerve. We also demonstrate miniaturisation potential by fabricating multi-optrode arrays, by developing a process that automatically matches each transducer element area with that of its corresponding biological interface. Significance. Our method of employing LCs to convert bioelectric signals into the optical domain will pave the way for the deployment of high-bandwidth optical telecommunications techniques in ultra-miniature clinical diagnostic and research laboratory neural and cardiac interfaces.
引用
收藏
页数:17
相关论文
共 41 条
[1]   Recent progress in optical voltage-sensor technology and applications to cardiac research: from single cells to whole hearts [J].
Acker, Corey D. ;
Yan, Ping ;
Loew, Leslie M. .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2020, 154 :3-10
[2]   A biopotential optrode array: operation principles and simulations [J].
Al Abed, Amr ;
Srinivas, Hrishikesh ;
Firth, Josiah ;
Ladouceur, Francois ;
Lovell, Nigel H. ;
Silvestri, Leonardo .
SCIENTIFIC REPORTS, 2018, 8
[3]   Impedance Properties of Multi-Optrode Biopotential Sensing Arrays [J].
Almasri, Reem M. ;
Al Abed, Amr ;
Wei, Yuan ;
Wang, Han ;
Firth, Josiah ;
Poole-Warren, Laura A. ;
Ladouceur, Francois ;
Lehmann, Torsten ;
Lovell, Nigel H. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (05) :1674-1684
[4]   Voltage imaging to understand connections and functions of neuronal circuits [J].
Antic, Srdjan D. ;
Empson, Ruth M. ;
Knoepfel, Thomas .
JOURNAL OF NEUROPHYSIOLOGY, 2016, 116 (01) :135-152
[5]   Novel Mapping Strategies for Ventricular Tachycardia Ablation [J].
Aziz Z. ;
Tung R. .
Current Treatment Options in Cardiovascular Medicine, 2018, 20 (4)
[6]   Impact of Micro-, Mini- and Multi-Electrode Mapping on Ventricular Substrate Characterisation [J].
Berte, Benjamin ;
Zeppenfeld, Katja ;
Tung, Roderick .
ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2020, 9 (03) :128-135
[7]  
Borlich Martin, 2019, Card Electrophysiol Clin, V11, P449, DOI 10.1016/j.ccep.2019.05.006
[8]   Liquid crystal-based hydrophone arrays [J].
Brodzeli, Zourab ;
Silvestri, Leonardo ;
Michie, Andrew ;
Chigrinov, Vladimir G. ;
Guo, Qi ;
Pozhidaev, Eugene P. ;
Kiselev, Alexei D. ;
Ladouceur, Francois .
Photonic Sensors, 2012, 2 (03) :237-246
[9]   Reflective mode of deformed-helix ferroelectric liquid crystal cells for sensing applications [J].
Brodzeli, Zourab ;
Silvestri, Leonardo ;
Michie, Andrew ;
Guo, Qi ;
Pozhidaev, Evgeny P. ;
Chigrinov, Vladimir ;
Ladouceur, Francois .
LIQUID CRYSTALS, 2013, 40 (10) :1427-1435
[10]   Sensors at Your Fibre Tips: A Novel Liquid Crystal-Based Photonic Transducer for Sensing Systems [J].
Brodzeli, Zourab ;
Silvestri, Leonardo ;
Michie, Andrew ;
Guo, Qi ;
Pozhidaev, Evgeny P. ;
Chigrinov, Vladimir ;
Ladouceur, Francois .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2013, 31 (17) :2940-2946