SCALING AND CFD ANALYSES FOR A SINGLE PHASE NATURAL CIRCULATION LOOP

被引:0
作者
Zhang, Weizhong [1 ]
Lin, Qian [1 ]
Si, Shengyi [1 ]
机构
[1] Shanghai Nucl Engn Res & Design Inst, Adv Nucl Power Technol R&D Ctr, 29 Hongcao Rd, Shanghai 200233, Peoples R China
来源
PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 8 | 2017年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Scaling analysis based on scaling laws was performed first for a single-phase natural circulation loop. Two geometrical reduced models were built. Numerical simulations for them using a CFD code named FLUENT were carried out. The calculated heat removal capabilities of the two reduced models show good agreement with the predicted results by the RELAP5/Mod3.2. The reversely deduced heat removal capabilities of the loop prototype from the numerically calculated results agree well with the prediction by the RELAP5/Mod3.2 for full height scaling model.
引用
收藏
页数:8
相关论文
共 7 条
  • [1] [Anonymous], 2011, ANSYS WORKB REL 14 0, P11
  • [2] [Anonymous], 1998, SUMM REV IND ASS REP, VVII, P2
  • [3] [Anonymous], 1995, RELAP5 MOD3 2 COD MA
  • [4] Chengge Lin, 2008, ADV PASSIVE PLANT AP, P195
  • [5] SCALING LAWS FOR THERMAL-HYDRAULIC SYSTEM UNDER SINGLE-PHASE AND 2-PHASE NATURAL CIRCULATION
    ISHII, M
    KATAOKA, I
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1984, 81 (03) : 411 - 425
  • [6] Lin Q., 2015, RES PASSIVE CONTAINM, V4, P10
  • [7] Yu P.A., 2001, THERMAL HYDRAULIC AN, P88