A novel extraction procedure coupled with gas chromatography-mass spectrometric detection for quantification of organochlorine pesticides (OCPs) in water is described. Amphiphilic polyhydroxylated polyparaphenylene (PH-PPP) was synthesized and coated on the surfaces of a porous polypropylene hollow fiber membrane (HFM). Due to the high porosity of the HFM, maximum active surface area to achieve high extraction efficiency is expected. The polymer-coated HFM was used for the extraction of 15 OCPs from water. The extraction efficiency was compared with emerging and established methods such as liquid-phase microextraction (LPME), solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) techniques. We term the current procedure as polymer-coated hollow fiber microextraction (PC-HFME). PC-HFME showed good selectivity and sensitivity. Detection limits for OCPs were in the range of 0.001-0.008 mug l(-1). The sensitivity and selectivity of the coated HFM could be adjusted by changing the characteristics of the coated PH-PPP film. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 30 条
[1]   Liquid-phase microextraction combined with capillary electrophoresis, a promising tool for the determination of chiral drugs in biological matrices [J].
Andersen, S ;
Halvorsen, TG ;
Pedersen-Bjergaard, S ;
Rasmussen, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :303-312
[2]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[3]  
2-4
[4]   Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :161-169
[5]   Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry [J].
Basheer, C ;
Balasubramanian, R ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) :11-20
[6]   Determination of organochlorine pesticides in seawater using liquid-phase hollow fibre membrane microextraction and gas chromatography-mass spectrometry [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) :191-199
[7]   Synthesis of a novel optically tunable amphiphilic poly(p-phenylene):: Influence of hydrogen bonding and metal complexation on optical properties [J].
Baskar, C ;
Lai, YH ;
Valiyaveettil, S .
MACROMOLECULES, 2001, 34 (18) :6255-6260
[8]   Solid-phase microextraction in pesticide residue analysis [J].
Beltran, J ;
López, FJ ;
Hernández, F .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :389-404
[9]   Application of polyphenylmethylsiloxane coated fiber for solid-phase microextraction combined with microwave-assisted extraction for the determination of organochlorine pesticides in Chinese teas [J].
Cai, LS ;
Xing, J ;
Dong, L ;
Wu, CY .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :11-21
[10]  
CHEE KK, 1999, APPL SOLID PHASE MIC, P212