Determining isotope ratios using laser ablation sampling in air with MC-ICPMS

被引:13
作者
Dorta, Ladina [1 ]
Kovacs, Robert [1 ]
Koch, Joachim [1 ]
Nishiguchi, Kohei [2 ]
Utani, Keisuke [2 ]
Guenther, Detlef [1 ]
机构
[1] ETH, Dept Chem & Appl Biosci, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
[2] J Sci Lab Co Ltd, Minami Ku, Kyoto 6018144, Japan
关键词
INDUCTIVELY-COUPLED PLASMA; MASS-SPECTROMETRY; ELEMENTAL FRACTIONATION; POTTERY GLAZES; LU-HF; FEMTOSECOND; ZIRCON; MS; NANOSECOND; PROVENANCE;
D O I
10.1039/c3ja50126d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotope ratio determination in solids sampled in air under atmospheric pressure using laser ablation with direct introduction into an ICPMS was carried out. The results obtained on the metal brass, and two minerals galena and zircon are reported in this manuscript. The samples were ablated in air and the laser-generated aerosol was aspirated into a gas exchange device (GED), where the air was replaced with Ar and transported into a multicollector-inductively coupled plasma mass spectrometer (MC-ICPMS). To demonstrate the capability of this sampling method, the results were compared to the results obtained using conventional laser ablation (LA)-MC-ICPMS in helium in a sealed cell. Data show that comparable in-run (0.03-1.61%) and external (0.002-0.254%) precisions can be obtained. The accuracy (0.000-0.192%) of both methods was also comparable. However, the atmospheric sampling method gave lower intensities, by up to a factor of 5. Visualization of the aerosol extraction indicates that some material was lost prior to gas exchange. However, this method is suitable for isotopic determination of bulk materials for samples which are too large to fit into an ablation cell or too valuable to be cut into smaller pieces.
引用
收藏
页码:1513 / 1521
页数:9
相关论文
共 38 条
  • [1] An open, non-contact cell for laser ablation-inductively coupled plasma-mass spectrometry
    Asogan, Dhinesh
    Sharp, Barry L.
    O'Connor, Ciaran J. P.
    Green, Damon A.
    Hutchinson, Robert W.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (07) : 917 - 923
  • [2] Beard B. L., 2012, GOLDSCHM C MONTR
  • [3] Depth profile analysis of various titanium based coatings on steel and tungsten carbide using laser ablation inductively coupled plasma -: "time of flight" mass spectrometry
    Bleiner, D
    Plotnikov, A
    Vogt, C
    Wetzig, K
    Günther, D
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3): : 221 - 226
  • [4] Isotopic compositions of the elements, 2001
    Böhlke, JK
    de Laeter, JR
    De Bièvre, P
    Hidaka, H
    Peiser, HS
    Rosman, KJR
    Taylor, PDP
    [J]. JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 2005, 34 (01) : 57 - 67
  • [5] Effects of crater development on fractionation and signal intensity during laser ablation inductively coupled plasma mass spectrometry
    Borisov, OV
    Mao, XL
    Russo, RE
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) : 1693 - 1704
  • [6] LASER VAPORIZATION OF SOLID METAL SAMPLES INTO AN INDUCTIVELY COUPLED PLASMA
    CARR, JW
    HORLICK, G
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (01) : 1 - 15
  • [7] Experimental assessment of a large sample cell for laser ablation-ICP-MS, and its application to sediment core micro-analysis
    Carugati, Gabriele
    Rauch, Sebastien
    Kylander, Malin E.
    [J]. MICROCHIMICA ACTA, 2010, 170 (1-2) : 39 - 45
  • [8] Provenance of Early Bronze Age metal artefacts in Western Switzerland using elemental and lead isotopic compositions and their possible relation with copper minerals of the nearby Valais
    Cattin, Florence
    Guenette-Beck, Barbara
    Curdy, Philippe
    Meisser, Nicolas
    Ansermet, Stefan
    Hofmann, Beda
    Kuendig, Rainer
    Hubert, Vera
    Woerle, Marie
    Hametner, Kathrin
    Guenther, Detlef
    Wichser, Adrian
    Ulrich, Andrea
    Villa, Igor M.
    Besse, Marie
    [J]. JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2011, 38 (06) : 1221 - 1233
  • [9] In situ determination of precise stable Si isotope ratios by UV-femtosecond laser ablation high-resolution multi-collector ICP-MS
    Chmeleff, Jerome
    Horn, Ingo
    Steinhoefel, Grit
    von Blanckenburg, Friedhelm
    [J]. CHEMICAL GEOLOGY, 2008, 249 (1-2) : 155 - 166
  • [10] LEAD ISOTOPE ANALYSIS OF TANG SANCAI POTTERY GLAZES FROM GONGYI KILN, HENAN PROVINCE AND HUANGBAO KILN, SHAANXI PROVINCE
    Cui, J. F.
    Lei, Y.
    Jin, Z. B.
    Huang, B. L.
    Wu, X. H.
    [J]. ARCHAEOMETRY, 2010, 52 : 597 - 604