Automatic chemiluminescence-based determination of carbaryl in various types of matrices

被引:26
作者
Pulgarín, JAM [1 ]
Molina, AA [1 ]
López, PF [1 ]
机构
[1] Univ Castilla La Mancha, Dept Analyt Chem & Food Technol, E-13071 Ciudad Real, Spain
关键词
carbaryl; chemiluminescence; cerium; commercial preparations; water; soil; grain;
D O I
10.1016/j.talanta.2005.04.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbaryl, a modern pesticide widely used for both agricultural and non-agricultural purposes, was determined from the chemiluminescence produced in its reaction with Ce(IV) in a nitric acid medium containing rhodamine 6G as sensitizer, using flow-injection techniques. A straightforward automatic method based on measurements peak height and peak area, which are directly proportional to the carbaryl concentration, was thus developed. Calibration graphs are linear over the concentration range from 50 to 2000 ng mL(-1). The limit of detection, as determined according to Clayton, is 45.6 and 28.7 ng mL(-1) for peak height and peak area measurements, respectively. The relative standard deviation for 10 samples was less than 1.4% with both types of measurements. Two commercial formulations containing carbaryl were analysed using both types of measurements, which provided acceptable recovery values. Solid-phase extraction was used to concentrate and separate the analyte from the matrix. The method was successfully applied to the analysis of spiked water samples as well as in soil and grain samples. The proposed method exhibited a high selectivity no other pesticide containing the naphthalene group such as antu, napropamide or naftalam, etc., was found to interfere with the determination of carbaryl. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:586 / 593
页数:8
相关论文
共 47 条
[1]  
ABBOTT R W, 1986, Analytical Proceedings, V23, P25
[2]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[3]  
Alonso MCS, 2001, ANAL CHIM ACTA, V437, P225
[4]   CHEMILUMINESCENCE DETERMINATION OF BUPRENORPHINE HYDROCHLORIDE BY FLOW-INJECTION ANALYSIS [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1986, 185 :329-333
[5]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF FOLIC-ACID IN PHARMACEUTICAL FORMULATIONS [J].
ALWARTHAN, AA .
ANALYTICAL SCIENCES, 1994, 10 (06) :919-922
[6]   Permanganate-based chemiluminescence analysis of cefadroxil monohydrate in pharmaceutical samples and biological fluids using flow injection [J].
Aly, FA ;
Alarfaffj, NA ;
Alwarthan, AA .
TALANTA, 1998, 47 (02) :471-478
[7]   Flow-injection chemiluminometric determination of some phenothiazines in dosage forms and biological fluids [J].
Aly, FA ;
Alarfaj, NA ;
Alwarthan, AA .
ANALYTICA CHIMICA ACTA, 1998, 358 (03) :255-262
[8]   Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides [J].
Anastassiades, M ;
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :163-184
[9]   Flow methods for the determination of polycyclic aromatic hydrocarbons using low power photomultiplier tube and charge coupled device chemiluminescence detection [J].
Andrew, KN ;
Sanders, MG ;
Forbes, S ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :113-120
[10]  
ANDREWS ARJ, 1989, ANAL CHIM ACTA, V26, P368