Argon laser peripheral iridoplasty for chronic primary angle-closure and angle-closure glaucoma in caucasians

被引:6
作者
Pillunat, Karin R. [1 ]
Spoerl, Eberhard [1 ]
Orphal, Johanna [1 ]
Pillunat, Lutz E. [1 ]
机构
[1] Tech Univ, Med Fac Carl Gustav Carus, Dept Ophthalmol, Fetscherstr 74, D-01307 Dresden, Germany
关键词
argon laser peripheral iridoplasty; nonpupillary block mechanisms; primary angle-closure; primary angle-closure glaucoma; CHAMBER DEPTH MEASUREMENTS; LENS EXTRACTION; ANTERIOR; IRIS; PENTACAM; EPIDEMIOLOGY; ASSOCIATION; PREVALENCE; PRESSURE; PEOPLE;
D O I
10.1111/aos.13878
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate whether the peripheral thinning and shrinking of the iris as induced with Argon laser peripheral iridoplasty (ALPI) has an effect on intraocular pressure (IOP), angle structure and 3-D anterior segment (AS) morphology in Caucasians with chronic primary angle-closure (PAC) and primary angle-closure glaucoma (PACG). Methods Twenty-four eyes of 24 patients (age 67.7 +/- 8.9 years; seven males; 17 females) diagnosed with PAC (n = 10) or PACG (n = 14) were assigned for ALPI prior to laser peripheral iridotomy (LPI) and consecutively enrolled in this prospective interventional study. Intraocular pressure (IOP) was measured with Goldmann applanation tonometry, angle structure with gonioscopy using the Shaffer grading system and AS morphology with the Pentacam rotating Scheimpflug camera prior to and 3 months after ALPI. Intraocular pressure (IOP)-lowering medication was not changed during follow-up. Results Intraocular pressure (IOP) changed statistically significantly from 18.8 +/- 3.6 to 14.7 +/- 3.1 mmHg (p < 0.001). Gonioscopy showed a statistically significant angle widening in all four quadrants: nasally from Shaffer 1.04 +/- 0.98 to 2.54 +/- 1.1 (p < 0.001), superiorly from 0.39 +/- 0.66 to 1.58 +/- 1.21 (p < 0.001), temporally from 0.87 +/- 1.01 to 2.17 +/- 1.24 (p = 0.001) and inferiorly from 1.22 +/- 0.74 to 2.75 +/- 0.9 (p < 0.001). Pentacam parameters like anterior chamber depth, volume and angle did not increase statistically significantly. Conclusion Argon laser peripheral iridoplasty (ALPI) is a safe and effective procedure for reducing appositional angle-closure and thus IOP in nonacute PAC and PACG patients.
引用
收藏
页码:E225 / E230
页数:6
相关论文
共 34 条
[11]   Qualitative Evaluation of the Iris and Ciliary Body by Ultrasound Biomicroscopy in Subjects With Angle Closure [J].
Ku, Judy Y. ;
Nongpiur, Monisha E. ;
Park, Judy ;
Narayanaswamy, Arun K. ;
Perera, Shamira A. ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
Baskaran, Mani ;
Aung, Tin .
JOURNAL OF GLAUCOMA, 2014, 23 (09) :583-588
[12]   Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan [J].
Lackner, Birgit ;
Schmidinger, Gerald ;
Skorpik, Christian .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) :858-861
[13]   Argon laser peripheral iridoplasty versus conventional systemic medical therapy in treatment of acute primary angle-closure glaucoma - A prospective, randomized, controlled trial [J].
Lam, DSC ;
Lai, JSM ;
Tham, CCY ;
Chua, JKH ;
Poon, ASY .
OPHTHALMOLOGY, 2002, 109 (09) :1591-1596
[14]   Predictors of long-term progression in the early manifest glaucoma trial [J].
Leske, M. Cristina ;
Heijl, Anders ;
Hyman, Leslie ;
Bengtsson, Boel ;
Dong, LiMing ;
Yang, Zhongming .
OPHTHALMOLOGY, 2007, 114 (11) :1965-1972
[15]   Comparison of the Prevalence of Plateau Iris Configurations Between Angle-closure Glaucoma and Open-angle Glaucoma Using Ultrasound Biomicroscopy [J].
Mochizuki, Hideki ;
Takenaka, Joji ;
Sugimoto, Yosuke ;
Takamatsu, Michiya ;
Kiuchi, Yoshiaki .
JOURNAL OF GLAUCOMA, 2011, 20 (05) :315-318
[16]   Argon Laser Peripheral Iridoplasty for Primary Angle-Closure Glaucoma A Randomized Controlled Trial [J].
Narayanaswamy, Arun ;
Baskaran, Mani ;
Perera, Shamira A. ;
Nongpiur, Monisha E. ;
Htoon, Hla M. ;
Tun, Tin A. ;
Wong, Tina T. ;
Goh, David ;
Su, Daniel H. ;
Chew, Paul T. K. ;
Ho, Ching-Lin ;
Aung, Tin .
OPHTHALMOLOGY, 2016, 123 (03) :514-521
[17]   Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device [J].
Nemeth, Gabor ;
Vajas, Attila ;
Kolozsvari, Bence ;
Berta, Andras ;
Modis, Laszlo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08) :1331-1335
[18]  
Ng WS, 2012, COCHRANE DATABASE SY
[19]   Angle closure glaucoma: a mechanistic review [J].
Nongpiur, Monisha E. ;
Ku, Judy Y. F. ;
Aung, Tin .
CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (02) :96-101
[20]   The number of people with glaucoma worldwide in 2010 and 2020 [J].
Quigley, HA ;
Broman, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) :262-267