Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: Implications for catheter ablation techniques for atrial fibrillation

被引:143
|
作者
Mansour, M
Holmvang, G
Sosnovik, D
Migrino, R
Abbara, S
Ruskin, J
Keane, D
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol,Cardiac Arrhythmia Unit, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
关键词
atrial fibrillation; pulmonary; vein isolation; magnetic resonance imaging; catheter ablation;
D O I
10.1046/j.1540-8167.2004.03515.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PV Anatomy by MRA. Introduction: Pulmonary vein (PV) isolation for atrial fibrillation (AF) currently is performed using either an ostial or an extra-ostial approach. The objective of this study was to analyze by three-dimensional (3D) magnetic resonance angiography (MRA) the anatomy of the PVs in order to detect structural variability that would impact the choice of ablation approach. Methods and Results: Three-dimensional MRA was performed in 105 patients undergoing PV isolation. The ostial diameter, branching pattern, and PV angulation were analyzed. Fifty-nine(56%) patients had the typical pattern of 4 PVs with 4 separate ostia, 30 (29%) patients had an additional PV, and 18 (17%) patients had a left common PV trunk. In two patients, there were three right-sided veins and a common left-sided trunk, giving rise to four ostia: three on the right and one on the left. Two different populations of right middle PVs were noted: one where the additional vein projected anteriorly to drain the right middle lobe and one posterior to drain the superior portion of the right lower lobe. The average intrapatient variability in PV diameter was 7.9 +/- 4.2 mm. The PV ostium was <10 mm in 26 (25%) patients and >25 mm in 15 (14%) patients. The first branch originated 6.7 +/- 2.3 mm from the ostium. The left superior, right superior, right inferior, and left interior PVs were found to enter the left atrium at the following angles: 32 +/- 13degrees,131 +/- 11degrees,206 +/- 16degrees, and 329 +/- 14degrees, respectively. Forty-nine patients (47%) had at least one funnel shaped PV. Conclusion: This largest PV imaging study to date demonstrates that MRA is a valuable tool that allows detection of marked intrapatient and interpatient anatomic variability of the PVs. These findings suggest that, at least in some patients, circumferential extra-ostial left atrial encirclement of the PVs may be preferable to ostial PV isolation. These findings also may have significant implications on the future development of coil- and balloon-based catheter ablation designs for AF ablation.
引用
收藏
页码:387 / 393
页数:7
相关论文
共 50 条
  • [31] Total pulmonary vein occlusion as a consequence of catheter ablation of atrial fibrillation
    Ernst, S
    Ouyang, F
    Goya, M
    Volkmer, M
    Vogtmann, T
    Hebe, J
    Kuck, KH
    EUROPEAN HEART JOURNAL, 2001, 22 : 244 - 244
  • [32] Collateral pulmonary vein after catheter ablation therapy for atrial fibrillation
    Nagai, Kyoko
    Kotake, Akio
    Hori, Yoshiro
    Takeyama, Nobuyuki
    Tanaka, Eliko
    Tashiro, Yuki
    Hashimoto, Toshi
    Wakatsuki, Daisuke
    Suzuki, Hiroshi
    BJR CASE REPORTS, 2021, 7 (04):
  • [33] Reversal of pulmonary vein remodeling after catheter ablation of atrial fibrillation
    JiaHui WU
    HungKei LI
    Daniel M Couri
    Philip A Araoz
    YingHsiang Lee
    ChangSheng MA
    Douglas L Packer
    YongMei CHA
    Journal of Geriatric Cardiology, 2016, 13 (02) : 163 - 168
  • [34] The Impact of Pulmonary Vein Anatomy on the Outcomes of Catheter Ablation for Atrial Fibrillation
    Istratoaie, Sabina
    Rosu, Radu
    Cismaru, Gabriel
    Vesa, Stefan C.
    Puiu, Mihai
    Zdrenghea, Dumitru
    Pop, Dana
    Buzoianu, Anca D.
    MEDICINA-LITHUANIA, 2019, 55 (11):
  • [35] Role of imaging techniques in preparation for catheter ablation of atrial fibrillation
    Mansour, M
    Holmvang, G
    Ruskin, J
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) : 1107 - 1108
  • [36] The effect of pulmonary vein anatomy on outcome of catheter ablation for atrial fibrillation
    Aursulesei, S.
    Cismaru, G.
    Rosu, R.
    Puiu, M.
    Gusetu, G.
    Zdrenghea, D.
    Pop, D.
    EUROPEAN HEART JOURNAL, 2018, 39 : 203 - 203
  • [37] Pulmonary vein stenosis complicating catheter ablation of focal atrial fibrillation
    Scanavacca, MI
    Kajita, LJ
    Vieira, M
    Sosa, EA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (06) : 677 - 681
  • [38] Pulmonary Vein Obstruction After Catheter Ablation Following Atrial Fibrillation
    Akutsu, Yasushi
    Kaneko, Kyouichi
    Kodama, Yusuke
    Li, Hui-Ling
    Suyama, Jumpei
    Shinozuka, Akira
    Gokan, Takehiko
    Hamazaki, Yuji
    Tanno, Kaoru
    Kobayashi, Youichi
    CIRCULATION, 2011, 123 (08) : E251 - E252
  • [39] Total pulmonary vein occlusion following catheter ablation of atrial fibrillation
    Ernst, S
    Ouyang, F
    Goya, M
    Hoffmann-Riem, M
    Loeber, F
    Volkmer, M
    Kuck, KH
    CIRCULATION, 2001, 104 (17) : 159 - 159
  • [40] REVERSE PULMONARY VEIN REMODELING AFTER CATHETER ABLATION FOR ATRIAL FIBRILLATION
    Wu, Jiahui
    Li, Hung-Kei
    Couri, Daniel
    Araoz, Philip
    Ma, Changsheng
    Packer, Douglas
    Cha, Yong-Mei
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E608 - E608