Test-retest variability of distortion-product otoacoustic emissions in human ears with normal hearing

被引:36
作者
Zhao, F [1 ]
Stephens, D [1 ]
机构
[1] Univ Wales Hosp, Welsh Hearing Inst, Cardiff CF4 4XN, S Glam, Wales
来源
SCANDINAVIAN AUDIOLOGY | 1999年 / 28卷 / 03期
关键词
distortion product otoacoustic emissions (DPOAEs); normal hearing; repeatability; variability;
D O I
10.1080/010503999424743
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
in the present study, the test-retest variability of distortion product otoacoustic emissions (DPOAEs) due to various causes has been assessed quantitatively at individual frequencies using the ILO88/92 system. The short-term variance was generally lower than 3 dB(2). Changing the position and the fit of the probe may affect the level of background noise in the ear canal, which interferes with the responses of the DPOAEs mainly at low frequencies and can also influence the interaction of the resonances of the outer ear and acoustic stimuli. The long-term variance was significantly greater than, short-term variance, but did not differ significantly from variance of refitting the probe. The total DPOAE variance was small across all the frequencies above 1000 Hz except for a small peak in the 2500 Hz range. This may be related to the low response amplitudes in this region. The Limitation of DPOAE detection at frequencies below 1000 Hz must lead to caution in the interpretation of results in this frequency range. The magnitude of the total variance was similar to that found in audiometric studies.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 18 条
[1]  
Bray P.J., 1989, PhD thesis
[2]   Individual differences and the reliability of 2F1-F2 distortion product otoacoustic emissions: Effects of time-of-day, stimulus variables, and gender [J].
Cacace, AT ;
McClelland, WA ;
Weiner, J ;
McFarland, DJ .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (06) :1138-1148
[3]   TEST RETEST RELIABILITY OF DISTORTION-PRODUCT AND TRANSIENTLY EVOKED OTOACOUSTIC EMISSIONS [J].
FRANKLIN, DJ ;
MCCOY, MJ ;
MARTIN, GK ;
LONSBURYMARTIN, BL .
EAR AND HEARING, 1992, 13 (06) :417-429
[4]   THE BEHAVIOR OF THE ACOUSTIC DISTORTION PRODUCT, 2F1-F2, FROM THE HUMAN EAR AND ITS RELATION TO AUDITORY-SENSITIVITY [J].
GASKILL, SA ;
BROWN, AM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (02) :821-839
[5]   CLINICAL-APPLICATION OF OTOACOUSTIC EMISSIONS - WHAT DO WE KNOW ABOUT FACTORS INFLUENCING MEASUREMENT AND ANALYSIS [J].
HALL, JW ;
BAER, JE ;
CHASE, PA ;
SCHWABER, MK .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1994, 110 (01) :22-38
[6]   A GUIDE TO THE EFFECTIVE USE OF OTOACOUSTIC EMISSIONS [J].
KEMP, DT ;
RYAN, S ;
BRAY, P .
EAR AND HEARING, 1990, 11 (02) :93-105
[7]   DISTORTION PRODUCT EMISSIONS IN HUMANS .1. BASIC PROPERTIES IN NORMALLY HEARING SUBJECTS [J].
LONSBURYMARTIN, BL ;
HARRIS, FP ;
HAWKINS, MD ;
STAGNER, BB ;
MARTIN, GK .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1990, 99 (05) :3-14
[8]  
LONSBURYMARTIN BL, 1997, 9 INT S AUD MED AALB
[9]  
MARGOLIS RH, 1985, HDB CLIN AUDIOLOGY, P439
[10]  
MOULIN A, 1994, AUDIOLOGY, V33, P305