Use of bone graft substitutes in the management of tibial plateau fractures

被引:64
作者
Goff, Thomas [1 ]
Kanakaris, Nikolaos K. [1 ]
Giannoudis, Peter V. [1 ]
机构
[1] Leeds Teaching Hosp NHS Trust, Acad Dept Trauma & Orthopaed, Leeds, W Yorkshire, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷
关键词
Bone graft; Plateau fracture; Substitutes; Cement; Review; CALCIUM-PHOSPHATE CEMENT; INTERNAL-FIXATION; OPEN REDUCTION; FOLLOW-UP; INTERPOROUS HYDROXYAPATITE; SURGICAL-TREATMENT; CANCELLOUS BONE; COMPLICATIONS; ALLOGRAFT; AUGMENTATION;
D O I
10.1016/S0020-1383(13)70019-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The current available evidence for the use of bone graft substitutes in the management of subchondral bone defects associated with tibial plateau fractures as to their efficiency and safety has been collected following a literature review of the Ovid MEDLINE (1948-Present) and EMBASE (1980-Present). Nineteen studies were analysed reporting on 672 patients (674 fractures), with a mean age of 50.35 years (range 15-89), and a gender ratio of 3/2 males/females. The graft substitutes evaluated in the included studies were calcium phosphate cement, hydroxyapatite granules, calcium sulphate, bioactive glass, tricalcium phosphate, demineralised bone matrix, allografts, and xenograft. Fracture healing was uneventful in over 90% of the cases over a variant period of time. Besides two studies reporting on injectable calcium phosphate cement excellent incorporation was reported within 6 to 36 months post-surgery. No correlation was made by any of the authors between poor incorporation/resorption and adverse functional or radiological outcome. Secondary collapse of the knee joint surface >= 2 mm was reported in 8.6% in the biological substitutes (allograft, DBM, and xenograft), 5.4% in the hydroxyapatite, 3.7% in the calcium phosphate cement, and 11.1% in the calcium sulphate cases. The recorded incidence of primary surgical site and donor site infection (3.6%) was not statistically significant different, however donor site-related pain was reported up to 12 months following autologous iliac bone graft (AIBG) harvest. Shorter total operative time, greater tolerance of early weight bearing, improved early functional outcomes within the first year post-surgery was also recorded in the studies reporting on the use of injectable calcium phosphate cement (Norian SRS). Despite a lack of good quality randomised control trials, there is arguably sufficient evidence supporting the use of bone graft substitutes at the clinical setting of depressed plateau fractures. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S86 / S94
页数:9
相关论文
共 78 条
[1]   Outcome of complex fractures of the tibial plateau treated with a beam-loading ring fixation system [J].
Ali, AM ;
Burton, M ;
Hashmi, M ;
Saleh, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05) :691-699
[2]   FRACTURES OF THE LATERAL TIBIAL CONDYLE TREATED BY SKELETAL TRACTION AND EARLY MOBILISATION - A REVIEW OF 60 CASES WITH SPECIAL REFERENCE TO THE LONG-TERM RESULTS [J].
APLEY, AG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1956, 38 (03) :699-708
[3]   Complications of iliac crest bone graft harvesting [J].
Arrington, ED ;
Smith, WJ ;
Chambers, HG ;
Bucknell, AL ;
Davino, NA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) :300-309
[4]   The use of calcium phosphate bone cement in fracture treatment [J].
Bajammal, Sohail S. ;
Zlowodzki, Michael ;
Lelwica, Amy ;
Tornetta, Paul, III ;
Einhorn, Thomas A. ;
Buckley, Richard ;
Leighton, Ross ;
Russell, Thomas A. ;
Larsson, Sune ;
Bhandari, Mohit .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06) :1186-1196
[5]   Bovine cancellous xenograft in the treatment of tibial plateau fractures in elderly patients [J].
Bansal, M. R. ;
Bhagat, S. B. ;
Shukla, D. D. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :779-784
[6]   Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates [J].
Barei, David P. ;
Nork, Sean E. ;
Mills, William J. ;
Coles, Chad P. ;
Henley, M. Bradford ;
Benirschke, Stephen K. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1713-1721
[7]   Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[8]  
Betz RR, 2002, ORTHOPEDICS, V25, pS561
[9]  
Bohner M, 2000, INJURY, V31, pS37
[10]   Allograft bone - The influence of processing on safety and performance [J].
Boyce, T ;
Edwards, J ;
Scarborough, N .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (04) :571-+