Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software

被引:88
作者
Kim, Gihyeon [2 ]
Jung, Ho-Joong [1 ]
Lee, Han-Jun [1 ]
Lee, Jae-Sung [1 ]
Koo, Seungbum [3 ]
Chang, Seung-Hwan [3 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Orthoped Surg, Seoul 140757, South Korea
[2] Chung Ang Univ, Coll Med, Dept Radiol, Seoul 140757, South Korea
[3] Chung Ang Univ, Sch Mech Engn, Seoul 140757, South Korea
基金
新加坡国家研究基金会;
关键词
Computed tomography; Accuracy; Reliability; Length; OsiriX; RECONSTRUCTION; TUNNELS;
D O I
10.1007/s10278-012-9458-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 22 条
  • [1] Avoiding tunnel collisions between fibular collateral ligament and ACL posterolateral bundle reconstruction
    Camarda, Lawrence
    D'Arienzo, Michele
    Patera, Giovanni Palermo
    Filosto, Leone
    LaPrade, Robert F.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (04) : 598 - 603
  • [2] G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    Faul, Franz
    Erdfelder, Edgar
    Lang, Albert-Georg
    Buchner, Axel
    [J]. BEHAVIOR RESEARCH METHODS, 2007, 39 (02) : 175 - 191
  • [3] The Location of Femoral and Tibial Tunnels in Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction Analyzed by Three-Dimensional Computed Tomography Models
    Forsythe, Brian
    Kopf, Sebastian
    Wong, Andrew K.
    Martins, Cesar A. Q.
    Anderst, William
    Tashman, Scott
    Fu, Freddie H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (06) : 1418 - 1426
  • [4] Greiner P., 2011, KNEE SURG SPORTS TRA
  • [5] Evaluation of the intercondylar roof impingement after anatomical double-bundle anterior cruciate ligament reconstruction using 3D-CT
    Iriuchishima, Takanori
    Horaguchi, Takashi
    Kubomura, Tatsuya
    Morimoto, Yusuke
    Fu, Freddie H.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (04) : 674 - 679
  • [6] Anatomic attachment of the ACL. Comparison between radiological and CT analysis
    Jenny, Jean-Yves
    Ciobanu, Eugene
    Clavert, Philippe
    Jaeger, Jean-Henri
    Kahn, Jean-Luc
    Kempf, Jean-Francoise
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (05) : 806 - 810
  • [7] An Analysis of the Posterior Cruciate Ligament Isometric Position Using an In Vivo 3-Dimensional Computed Tomography-Based Knee Joint Model
    Jeong, Woon-Seob
    Yoo, Yon-Sik
    Kim, Do-Young
    Shetty, Nagraj S.
    Smolinski, Patrick
    Logishetty, Kartik
    Ranawat, Anil
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (10) : 1333 - 1339
  • [8] MR/CT image fusion of the spine after spondylodesis: a feasibility study
    Karlo, C. A.
    Steurer-Dober, I.
    Leonardi, M.
    Pfirrmann, C. W. A.
    Zanetti, M.
    Hodler, J.
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (10) : 1771 - 1775
  • [9] Nonanatomic Tunnel Position in Traditional Transtibial Single-Bundle Anterior Cruciate Ligament Reconstruction Evaluated by Three-Dimensional Computed Tomography
    Kopf, Sebastian
    Forsythe, Brian
    Wong, Andrew K.
    Tashman, Scott
    Anderst, William
    Irrgang, James J.
    Fu, Freddie H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (06) : 1427 - 1431
  • [10] Anterior Cruciate Ligament Tunnel Position Measurement Reliability on 3-Dimensional Reconstructed Computed Tomography
    Lertwanich, Pisit
    Martins, Cesar A. Q.
    Asai, Shigehiro
    Ingham, Sheila J. M.
    Smolinski, Patrick
    Fu, Freddie H.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (03) : 391 - 398