Silver oxide-containing hydroxyapatite coating has in vivo antibacterial activity in the rat tibia

被引:82
作者
Akiyama, Takayuki [1 ]
Miyamoto, Hiroshi [2 ]
Yonekura, Yutaka [1 ]
Tsukamoto, Masatsugu [1 ]
Ando, Yoshiki [2 ,3 ]
Noda, Iwao [2 ,3 ]
Sonohata, Motoki [1 ]
Mawatari, Masaaki [1 ]
机构
[1] Saga Univ, Fac Med, Dept Orthopaed Surg, Saga 8498501, Japan
[2] Saga Univ, Fac Med, Dept Pathol & Microbiol, Saga 8498501, Japan
[3] KYOCERA Med Corp, Res Dept, Osaka 5320003, Japan
关键词
silver; hydroxyapatite; antibacterial activity; implant; methicillin-resistant Staphylococcus aureus (MRSA); COATED MEGAPROSTHESES; CYTOTOXICITY; IONS; KNEE;
D O I
10.1002/jor.22357
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bacterial infection is a serious postoperative complication of joint replacement. To prevent infections related to implantation, we have developed a novel antibacterial coating with Ag-containing hydroxyapatite (Ag-HA). In the present study, we examined the antibacterial activity of Ag-HA implant coatings in the medullary cavity of rat tibiae. Forty 10-week-old rats received implantation of Ag-HA- or HA-coated titanium rods, then were inoculated with approximate to 1.0x102 colony-forming units of methicillin-resistant Staphylococcus aureus. Bacterial counts were calculated for rats euthanized at 24, 48, and 72h postoperatively. Serum levels of Ag (in the Ag-HA group only) were calculated for rats euthanized at 24, 48, 72h and 4 weeks. Radiographic evaluations of bone infection were also performed at 4 weeks. Tibiae from both groups showing infection were evaluated histologically. Significant differences in bacterial counts were seen at 24, 48, and 72h. Mean concentrations of Ag in serum peaked about 48h after implantation, then gradually decreased. Mean radiographic scores for infection were significantly lower with Ag-HA implants than with HA implants. Histological examination showed better results for abscesses, bone resorption, and destruction of cortical bone around Ag-HA-coated implants. These results indicate that Ag-HA coatings may help prevent surgical-site infections associated with joint replacement. (c) 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1195-1200, 2013
引用
收藏
页码:1195 / 1200
页数:6
相关论文
共 24 条
[1]   Effect of Bacterial Media on the Evaluation of the Antibacterial Activity of a Biomaterial Containing Inorganic Antibacterial Reagents or Antibiotics [J].
Ando, Yoshiki ;
Miyamoto, Hiroshi ;
Noda, Iwao ;
Miyaji, Fumiaki ;
Shimazaki, Takafumi ;
Yonekura, Yutaka ;
Miyazaki, Masaki ;
Mawatari, Masaaki ;
Hotokebuchi, Takao .
BIOCONTROL SCIENCE, 2010, 15 (01) :15-19
[2]   Calcium phosphate coating containing silver shows high antibacterial activity and low cytotoxicity and inhibits bacterial adhesion [J].
Ando, Yoshiki ;
Miyamoto, Hiroshi ;
Noda, Iwao ;
Sakurai, Nobuko ;
Akiyama, Tomonori ;
Yonekura, Yutaka ;
Shimazaki, Takafumi ;
Miyazaki, Masaki ;
Mawatari, Masaaki ;
Hotokebuchi, Takao .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (01) :175-180
[3]   Antibacterial effect and cytotoxicity of Ag-doped functionally graded hydroxyapatite coatings [J].
Bai, Xiao ;
Sandukas, Stefan ;
Appleford, Mark ;
Ong, Joo L. ;
Rabiei, Afsaneh .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) :553-561
[4]   EFFECT OF SILVER IONS ON RESPIRATORY-CHAIN OF ESCHERICHIA-COLI [J].
BRAGG, PD ;
RAINNIE, DJ .
CANADIAN JOURNAL OF MICROBIOLOGY, 1974, 20 (06) :883-889
[5]   Microbiological comparison of a silver-coated and a non-coated needleless intravascular connector in clinical use [J].
Casey, A. L. ;
Karpanen, T. J. ;
Nightingale, P. ;
Cook, M. ;
Elliott, T. S. J. .
JOURNAL OF HOSPITAL INFECTION, 2012, 80 (04) :299-303
[6]   The infected total knee - Management options [J].
Cuckler, JM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :33-36
[7]   Anti-infective efficacy of silver-coated medical prostheses [J].
Darouiche, RO .
CLINICAL INFECTIOUS DISEASES, 1999, 29 (06) :1371-1377
[8]   Evidence for the use of silver-alloy-coated urethral catheters [J].
Davenport, K ;
Keeley, FX .
JOURNAL OF HOSPITAL INFECTION, 2005, 60 (04) :298-303
[9]   Silver nanoparticles: a brief review of cytotoxicity and genotoxicity of chemically and biogenically synthesized nanoparticles [J].
de Lima, Renata ;
Seabra, Amedea B. ;
Duran, Nelson .
JOURNAL OF APPLIED TOXICOLOGY, 2012, 32 (11) :867-879
[10]  
ELEK SD, 1957, BRIT J EXP PATHOL, V38, P573