Breath Analysis by Electronic Nose for Asthma detection

被引:0
作者
Shelat, Saumya J.
Patel, H. K.
Desai, M. D.
机构
来源
3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE 2012) | 2012年
关键词
Electronic Nose; Breath analysis; Nitric oxide; asthma; EXHALED NITRIC-OXIDE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of this paper is to determine Asthma by analyzing the Nitric oxide present in exhaled breath as a noninvasive method with the help of an electronic nose system based on Breath odor detection. Recognition of the presence of asthma in individuals is done by classifying the olfactory signal acquired through an electronic nose based on an array of sensors. Chemical compounds from the human body are important indicators which can be used for diagnosing human diseases. Electronic nose is an array of partially selective chemical sensor, where Nitric oxide is the Biomarker of Asthma. It is suggestive that measurements of exhaled NO can be clinically useful in noninvasive diagnosis as well as monitoring of inflammatory airway diseases. Exhaled NO levels were found higher in subjects with difficult asthma (mean 13.9 ppb, 95% CI 9.3 to 18.5) compared normal controls (7.4 ppb, 95% CI 6.9 to 7.8; p<0.002), however lower than levels in steroid naive mild asthmatics (36.9 ppb, 95% CI 34.6 to 39.3; p<0.001). Few doctors' measure's a patient's exhaled NO levels and helping them to decide for effective treatments as well as medication doses and may continue to measure for few more occasions for judging the response to treatment given.
引用
收藏
页数:5
相关论文
共 11 条
[1]  
ALVING K, 1993, EUR RESPIR J, V6, P1368
[2]  
Amico A. D, 2007, SENSOR ACTUAT B-CHEM, V130, P458
[3]  
Davis Cristina E., 2010, IEEE SENSORS J, V10
[4]  
Gardner J.W., 1999, Electronic Noses: Principles and Applications.
[5]  
Kodogiannis VS, 2002, 2002 FIRST INTERNATIONAL IEEE SYMPOSIUM INTELLIGENT SYSTEMS, VOL 1, PROCEEDINGS, P254, DOI 10.1109/IS.2002.1044264
[6]   Exhaled nitric oxide in paediatric asthma and cystic fibrosis [J].
Lundberg, JON ;
Nordvall, SL ;
Weitzberg, E ;
Kollberg, H ;
Alving, K .
ARCHIVES OF DISEASE IN CHILDHOOD, 1996, 75 (04) :323-326
[7]   EXPIRED NITRIC-OXIDE LEVELS DURING TREATMENT OF ACUTE ASTHMA [J].
MASSARO, AF ;
GASTON, B ;
KITA, D ;
FANTA, C ;
STAMLER, JS ;
DRAZEN, JM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) :800-803
[8]   Diagnostic Performance of an Electronic Nose, Fractional Exhaled Nitric Oxide, and Lung Function Testing in Asthma [J].
Montuschi, Paolo ;
Santonico, Marco ;
Mondino, Chiara ;
Pennazza, Giorgio ;
Mantini, Giulia ;
Martinelli, Eugenio ;
Capuano, Rosamaria ;
Ciabattoni, Giovanni ;
Paolesse, Roberto ;
Di Natale, Corrado ;
Barnes, Peter J. ;
D'Amico, Arnaldo .
CHEST, 2010, 137 (04) :790-796
[9]  
National Institutes of Health: National Heart Lung and Blood Institute, 2007, NIH PUBLICATION, V07-4051
[10]  
Osuna R., 1998, IEEE SPECTRUM, P22