Reproducibility of macular retinal nerve fiber layer and ganglion cell layer thickness measurements in a healthy pediatric population

被引:1
作者
Jimenez Santos, Maria [1 ]
Acebal Montero, Alejandra [1 ]
Saenz-Frances San Baldomero, Federico [1 ]
Valverde-Megias, Alcia [1 ]
Gomez de Liano, Rosario [1 ]
机构
[1] Hosp Clin Univ San Carlos, Dept Ophthalmol, C Martin Lagos S-N, Madrid 28040, Spain
关键词
Diagnostic techniques; strabismus; optics; refraction; instruments; glaucomas (pediatric); pediatric ophthalmology; neuro-ophthalmic disease; clinical tests; lens; cataract; OPTICAL COHERENCE TOMOGRAPHY; TEST-RETEST VARIABILITY; INNER; REPEATABILITY; GLAUCOMA; OCT;
D O I
10.1177/1120672120947614
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility of Spectralis spectral domain-OCT segmented ganglion cell layer (GCL) and macular retinal nerve fiber layer (mRNFL) measurements in a healthy children population. Methods: An observational, cross-sectional study was carried out on 79 children to measure the intraobserver reproducibility and the repeatability between a novel and an experienced operator of the segmented macular GCL and mRNFL. Interobserver and intraobserver reproducibility were defined by the intraclass correlation coefficient (ICC) and coefficients of variation (COV). Kruskal-Wallis test was used to determine statistical significance in the COV of three age groups children (younger than 6 years, between 6 and 12, and older than 12 years old). Results: The results from the intraoperator GCL thickness analysis were highly reproducible (COV < 6%) and reliable (ICCs > 0.81). When the measurements were compared between a novel and an experienced examiner lower ICCs and higher COV were found. COVs ranged from 1.85% (total volume area) to 5.57% at the central ETDRS subfield while the ICC vary from 0.632 (outer inferior) to 0.832 (inner inferior). The repeatability and reproducibility of the mRNFL thickness were lower, with ICCs ranging from 0.428 to 0.872 in the interobserver analysis and from 0.897 to 0.346 in the interobserver one. Conclusion: In the present study, we establish substantial reliability of the GCL thickness in children with Spectralis(R)SD-OCT in all the sectors, albeit lower than the reported in the literature with other SD-OCTs and in adults. The reproducibility and repeatability of the mRNFL were significantly lower. We were unable to find consistent statistical significant differences between the COV of the three age groups.
引用
收藏
页码:2087 / 2094
页数:8
相关论文
共 32 条
  • [1] Reproducibility of Optical Coherence Tomography Measurements in Children
    Altemir, Irene
    Pueyo, Victoria
    Elia, Noemi
    Polo, Vicente
    Larrosa, Jose M.
    Oros, Daniel
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (01) : 171 - 176
  • [2] Avery RA, 2014, AM J OPHTHALMOL, V158
  • [3] Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography
    Balasubramanian, Madhusudhanan
    Bowd, Christopher
    Vizzeri, Gianmarco
    Weinreb, Robert N.
    Zangwill, Linda M.
    [J]. OPTICS EXPRESS, 2009, 17 (05): : 4019 - 4036
  • [4] Comparison of Two Different OCT Systems: Retina Layer Segmentation and Impact on Structure-Function Analysis in Glaucoma
    Brandao, Livia M.
    Ledolter, Anna A.
    Schoetzau, Andreas
    Palmowski-Wolfe, Anja M.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [5] OCT for glaucoma diagnosis, screening and detection of glaucoma progression
    Bussel, Igor I.
    Wollstein, Gadi
    Schuman, Joel S.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 : 15 - 19
  • [6] Will Perimetry Be Performed to Monitor Glaucoma in 2025?
    Camp, Andrew S.
    Weinreb, Robert N.
    [J]. OPHTHALMOLOGY, 2017, 124 (12) : S71 - S75
  • [7] Comparison of Optical Coherence Tomography Measurement Reproducibility between Children and Adults
    Chung, Ho Kyung
    Han, Young Keun
    Oh, Sohee
    Kim, Seok Hwan
    [J]. PLOS ONE, 2016, 11 (01):
  • [8] Intrasession, intersession, and interexaminer variabilities of retinal nerve fiber layer measurements with spectral-domain OCT
    Cremasco, Fernanda
    Massa, Graziela
    Vidotti, Vanessa Goncalves
    de Carvalho Lupinacci, Alvaro Pedroso
    Costa, Vital Paulino
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (03) : 264 - 270
  • [9] Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software
    Ctori, Irene
    Huntjens, Byki
    [J]. PLOS ONE, 2015, 10 (06):
  • [10] TOPOGRAPHY OF GANGLION-CELLS IN HUMAN RETINA
    CURCIO, CA
    ALLEN, KA
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 300 (01) : 5 - 25