Implementation of point-of-care testing in a pediatric healthcare setting

被引:19
作者
Patel, Khushbu [1 ]
Suh-Lailam, Brenda B. [2 ,3 ]
机构
[1] UT Southwestern Med Ctr, Dept Pathol, Dallas, TX USA
[2] Ann & Robert H Lurie Childrens Hosp Chicago, Dept Pathol & Lab Med, 225 East Chicago Ave,Box 53, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Pathol, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
Point-of-care testing; pediatric; implementation; IMPROVING PATIENT SATISFACTION; ACADEMIC-MEDICAL-CENTER; EMERGENCY-DEPARTMENT; AMBULATORY PRACTICE; BLOOD-TRANSFUSIONS; DECISION-MAKING; IMPACT; MANAGEMENT; RADIOLOGY; INFLUENZA;
D O I
10.1080/10408363.2019.1590306
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Point-of-care testing (POCT) refers to testing performed outside the clinical laboratory near the patient or at the site of patient care. This could be in critical care settings like the intensive care unit (ICU) and emergency department (ED) or primary care settings like physician offices where testing is performed by nonlaboratory personnel. POCT circumvents several steps in central laboratory testing including specimen transportation and processing resulting in faster turnaround times. Provider access to rapid test results at the site of patient care allows for prompt medical decision making which can lead to improved patient outcomes, operational efficiencies, patient satisfaction, and even cost savings in some cases. In addition to providing results rapidly, POCT devices have small specimen volume requirements compared to central laboratory tests making POCT particularly attractive for pediatric healthcare settings. The availability of published reports on the impact of POCT implementation in pediatric care are helpful resources when evaluating the clinical necessity of POCT prior to implementation. Even though several studies have shown advantages to implementing POCT in different pediatric settings, it is important to note that limitations exist that might limit the utilization of certain POCTs in some pediatric populations. So, it is important that these limitations and the analytical performance of a test are considered while keeping the target patient population in mind. Since POCTs are performed by non-laboratory staff who are not trained laboratory personnel, one challenge with POCT is maintaining regulatory compliance and quality assurance. It is therefore important that regulatory and quality assurance programs be put in place prior to implementing POCT in the pediatric hospital. With advances in POCT technology, most POCT devices have the capability to interface to the laboratory information system (LIS) and electronic medical record (EMR). POCT device interfacing allows for improved compliance to regulatory and quality assurance standards. Maintaining a cost efficient POCT program is becoming increasingly important as hospitals and healthcare systems are undergoing consolidation and harmonization. This includes assessing the clinical and operational benefit of POCT before implementation and inventory management to ensure minimal reagent wastage. This review discusses these different considerations when implementing POCT with a focus on the pediatric healthcare setting.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 49 条
[1]  
Alves-Dunkerson JA, 2002, AM J CLIN PATHOL, V117, P809
[2]   Decreased patient charges following implementation of point-of-care cardiac troponin monitoring in acute coronary syndrome patients in a community hospital cardiology unit [J].
Apple, Fred S. ;
Chung, Adrine Y. ;
Kogut, Mary Ellen ;
Bubany, Susan ;
Murakami, MaryAnn M. .
CLINICA CHIMICA ACTA, 2006, 370 (1-2) :191-195
[3]   A National Study of the Impact of Rapid Influenza Testing on Clinical Care in the Emergency Department [J].
Blaschke, Anne J. ;
Shapiro, Daniel J. ;
Pavia, Andrew T. ;
Byington, Carrie L. ;
Ampofo, Krow ;
Stockmann, Chris ;
Hersh, Adam L. .
JOURNAL OF THE PEDIATRIC INFECTIOUS DISEASES SOCIETY, 2014, 3 (02) :112-118
[4]   The Benefits of a Rapid, Point-of-Care "Tnl-Only" Zero and 2-Hour Protocol for the Evaluation of Chest Pain Patients in the Emergency Department [J].
Blick, Kenneth E. .
CLINICS IN LABORATORY MEDICINE, 2014, 34 (01) :75-+
[5]   Point-of-Care Coagulation Testing in Cardiac Surgery [J].
Bolliger, Daniel ;
Tanaka, Kenichi A. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2017, 43 (04) :386-396
[6]   Impact of the rapid diagnosis of influenza on physician decision-making and patient management in the pediatric emergency department: Results of a randomized, prospective, controlled trial [J].
Bonner, AB ;
Monroe, KW ;
Talley, LI ;
Klasner, AE ;
Kimberlin, DW .
PEDIATRICS, 2003, 112 (02) :363-367
[7]   Immediate feedback of HbA1c levels improves glycemic control in type I and insulin-treated type 2 diabetic patients [J].
Cagliero, E ;
Levina, EV ;
Nathan, DM .
DIABETES CARE, 1999, 22 (11) :1785-1789
[8]   Patient satisfaction with point-of-care laboratory testing: Report of a quality improvement program in an ambulatory practice of an academic medical center [J].
Crocker, Benjamin ;
Lewandrowski, Elizabeth-Lee ;
Lewandrowski, Nicole ;
Gregory, Kimberly ;
Lewandrowski, Kent .
CLINICA CHIMICA ACTA, 2013, 424 :8-11
[9]   Implementation of Point-of-Care Testing in an Ambulatory Practice of an Academic Medical Center [J].
Crocker, J. Benjamin ;
Lee-Lewandrowski, Elizabeth ;
Lewandrowski, Nicole ;
Baron, Jason ;
Gregory, Kimberly ;
Lewandrowski, Kent .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2014, 142 (05) :640-646
[10]  
*CTR CLIN STAND QU, SC1511CLIA CTR CLIN