Assessing Feasibility of Real-time Ultrasound Monitoring in Stereotactic Body Radiotherapy of Liver Tumors

被引:18
作者
Zhong, Yahua [1 ,2 ]
Stephans, Kevin [1 ]
Qi, Peng [1 ]
Yu, Naichang [1 ]
Wong, John [3 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
[2] Wuhan Univ, Zhongnan Hosp, Dept Radiochemotherapy, Canc Clin Study Ctr, Wuhan, Hubei Province, Peoples R China
[3] Johns Hopkins Univ, Dept Radiat Oncol, Baltimore, MD 21218 USA
关键词
Real-time ultrasound; Stereotactic body radiotherapy; Hepatic tumor; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; PROSTATE-CANCER; DAILY CT; LOCALIZATION; SYSTEM; TRACKING; EXPERIENCE; GUIDANCE;
D O I
10.7785/tcrt.2012.500323
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To monitor tumor motion during stereotactic body radiotherapy (SBRT) for patients with liver cancer, an integrated ultrasound and kilo-voltage cone-beam computed tomography (KV-CBCT) system has been proposed. The presence of an ultrasound probe may interfere with the radiation beams. The purpose of this study is to minimize this interference by altering orientations of the ultrasound probe and directions of radiation beams while not compromising the quality of SBRT plans. Ten patients, who received SBRT of liver cancer, were randomly selected for this study. To simulate the presence of an ultrasound probe, a virtual probe was oriented either parallel or vertical to the longitudinal axis of the patient's body and was added on the surface of the patient's body at the nearest location to the tumor. For both the parallel and vertical probe orientations, 2 new SBRT (Probe-Para and Probe-Vert) plans that minimize the interference between the probe and radiation beams were created for each patient. These SBRT plans were compared to the original clinically accepted SBRT plans, with a treatment goal of 37.5 Gy to the planning target volume (PTV) in 3 fractions. Specific dosimetric endpoints were evaluated, including doses to 95% (D-95), of the PTV plan conformal index (CI), homogeneity index (HI), and relevant endpoint doses to organs at risk. For 2 patients with superficially located tumors, no clinically acceptable SBRT plans could be produced without the interference between the probe and radiation beams. For the remaining 8 patients, the Probe-Para plans allowed 7 patients to be treated with coplanar radiation beams (without moving the treatment couch during treatment) and 1 patient to be treated with non-coplanar beams (by moving the treatment couch during treatment). The Probe-Vert plans allowed 2 patients to be treated with coplanar beams and 6 patients to be treated with non-coplanar beams. The average D-95 of the PTV were 38.63 Gy +/- 0.14 (p = 0.65) for Probe-Para plans, 38.48 Gy +/- 0.31 (p = 0.33) for Probe-Vert plans, and 38.72 Gy +/- 0.14 for clinical SBRT plans. There were no significant differences (p > 0.05) in CI and HI of all SBRT plans. The endpoint doses to the liver, heart, esophagus, right kidney, and stomach also had no significant differences (p > 0.05). Except for superficial lesions, real-time ultrasound monitoring during liver SBRT is clinically feasible. Placing the ultrasound probe parallel to the longitudinal axis of the patient allows a greater probability of utilizing preferred coplanar beams.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 32 条
[1]   Online ultrasound image guidance for radiotherapy of prostate cancer: Impact of image acquisition on prostate displacement [J].
Artignan, X ;
Smitsmans, MHP ;
Lebesque, JV ;
Jaffray, DA ;
van Her, M ;
Bartelink, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02) :595-601
[2]   IMAGE-GUIDED RADIOTHERAPY (IGRT) FOR PROSTATE CANCER COMPARING kV IMAGING OF FIDUCIAL MARKERS WITH CONE BEAM COMPUTED TOMOGRAPHY (CBCT) [J].
Barney, Brandon M. ;
Lee, R. Jeffrey ;
Handrahan, Diana ;
Welsh, Keith T. ;
Cook, J. Taylor ;
Sause, William T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01) :301-305
[3]   Total error shift patterns for daily CT on rails image-guided radiotherapy to the prostate bed [J].
Cavalieri, Ronaldo ;
Gay, Hiram A. ;
Liu, Jingxia ;
Ferreira, Maria C. ;
Mota, Helvecio C. ;
Sibata, Claudio H. ;
Allison, Ron R. .
RADIATION ONCOLOGY, 2011, 6
[4]   Experience of ultrasound-based daily prostate localization [J].
Chandra, A ;
Dong, L ;
Huang, E ;
Kuban, DA ;
O'Neill, L ;
Rosen, I ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :436-447
[5]   Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control [J].
Dawson, LA ;
Eccles, C ;
Bissonnette, JP ;
Brock, KK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1247-1252
[6]   Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[7]   Radiation Therapy for Hepatocellular Carcinoma [J].
Feng, Mary ;
Ben-Josef, Edgar .
SEMINARS IN RADIATION ONCOLOGY, 2011, 21 (04) :271-277
[8]   A CT based correction method for speed of sound aberration for ultrasound based image guided radiotherapy [J].
Fontanarosa, Davide ;
Van der Meer, Skadi ;
Harris, Emma ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2011, 38 (05) :2665-2673
[9]   Feasibility of using ultrasound for real-time tracking during radiotherapy [J].
Hsu, A ;
Miller, NR ;
Evans, PM ;
Bamber, JC ;
Webb, S .
MEDICAL PHYSICS, 2005, 32 (06) :1500-1512
[10]   Hypofractionated Stereotactic Body Radiotherapy for Primary and Metastatic Liver Tumors Using the Novalis Image-Guided System: Preliminary Results Regarding Efficacy and Toxicity [J].
Iwata, Hiromitsu ;
Shibamoto, Yuta ;
Hashizume, Chisa ;
Mori, Yoshimasa ;
Kobayashi, Tatsuya ;
Hayashi, Naoki ;
Kosaki, Katsura ;
Ishikawa, Tetsuya ;
Kuzuya, Teiji ;
Utsunomiya, Setsuo .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (06) :619-627