Characterization of a peek composite segmental bone replacement implant

被引:22
作者
Corvelli, AA [1 ]
Roberts, JC
Biermann, PJ
Cranmer, JH
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Engn Mech, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD USA
关键词
D O I
10.1023/A:1004562732460
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A composite material of polyetheretherketone and short, chopped E-glass fibers was used to produce a segmental bone replacement implant. Problems with current metallic implants include stress-shielding of the surrounding bone and subsequent loosening of the implant. A better match between the bulk material properties of the implant and the bone it replaces can decrease the occurrence of these problems. Composite materials were chosen because their properties can be tailored to match the requirements. Material selection was accomplished with the aid of modeling software, which predicted the composite properties based on its composition and fiber directional parameters. Prototype parts were completed through a series of in-house molding and machining processes. Sections complete with an embedded metallic porous surface were tested to measure the strength of the attachment of the surface. The molded parts were characterized both destructively and nondestructively. The results of tensile tests performed on molded parts were comparable to those using commercially supplied samples. The fiber orientation was measured to verify the random positioning of fibers throughout the part, as assumed in the initial material selection. Ultrasonic C-scanned images confirmed that the molded parts had a very low density of air pockets or voids. (C) 1999 Kluwer Academic Publishers.
引用
收藏
页码:2421 / 2431
页数:11
相关论文
共 34 条
  • [1] EFFECT OF MOVEMENT ON BONDING OF POROUS METAL TO BONE
    CAMERON, HU
    PILLIAR, RM
    MACNAB, I
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (04): : 301 - 311
  • [2] BONE-FORMATION AND REMODELING AROUND IMPLANTED MATERIALS UNDER LOAD-BEARING CONDITIONS
    CHANG, YS
    OKA, M
    KOBAYASHI, M
    GU, HO
    LI, ZL
    KITSUGI, T
    NAKAMURA, T
    [J]. CLINICAL MATERIALS, 1994, 17 (04): : 181 - 187
  • [3] ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY
    CHEAL, EJ
    SPECTOR, M
    HAYES, WC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) : 405 - 422
  • [4] THE EFFECTS OF INTRA-MEDULLARY IMPLANTS ON BONE STRAINS AND REMODELING IN THE FEMUR
    COOK, SD
    WEINSTEIN, AM
    LUEDEMANN, R
    LAVERNIA, C
    SKINNER, HB
    KLAWITTER, JJ
    [J]. BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1982, 10 (01): : 21 - 40
  • [5] Cowin S. C., 1991, BONE MECH
  • [6] DUCHEYNE P, 1977, J BIOMED MATER RES, V11, P811, DOI 10.1002/jbm.820110603
  • [7] ELLIOTT RM, 1991, THESIS U MINNESOTA
  • [8] FAGAN M, 1994, ADV BIOENG, V28, P445
  • [9] MECHANICAL DETERMINANTS OF BONE MODELING
    FROST, HM
    [J]. METABOLIC BONE DISEASE & RELATED RESEARCH, 1982, 4 (04): : 217 - 229
  • [10] FIBER METAL COMPOSITES IN FIXATION OF SKELETAL PROSTHESIS
    GALANTE, J
    ROSTOKER, W
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (03): : 43 - 61