Mechanical response of 3D Insert® PCL to compression

被引:14
作者
Brunelli, M. [1 ]
Perrault, C. M. [1 ]
Lacroix, D. [1 ]
机构
[1] Univ Sheffield, Dept Mech Engn, INSIGNEO Inst In Silico Med, Sheffield S10 2TN, S Yorkshire, England
基金
欧洲研究理事会;
关键词
Mechanical compression; 3D PCL; Variability analysis; Micro computed tomography; POLYCAPROLACTONE SCAFFOLDS; IN-VITRO; DESIGN; POROSITY;
D O I
10.1016/j.jmbbm.2016.08.038
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D polymeric scaffolds are increasingly used for in vitro experiments aiming to mimic the environment found in vivo, to support for cellular growth and to induce differentiation through the application of external mechanical cues. In research, experimental results must be shown to be reproducible to be claimed as valid and the first clause to ensure consistency is to provide identical initial experimental conditions between trials. As a matter of fact, 3D structures fabricated in batch are supposed to present a highly reproducible geometry and consequently, to give the same bulk response to mechanical forces. This study aims to measure the overall mechanical response to compression of commercially available 3D Insert PCL scaffolds (3D PCL) fabricated in series by fuse deposition and evaluate how small changes in the architecture of scaffolds affect the mechanical response. The apparent elastic modulus (Ea) was evaluated by performing quasi-static mechanical tests at various temperatures showing a decrease in material stiffness from 5 MPa at 25 degrees C to 2.2 MPa at 37 degrees C. Then, a variability analysis revealed variations in Ea related to the repositioning of the sample into the testing machine, but also consistent differences comparing different scaffolds. To clarify the source of the differences measured in the mechanical response, the same scaffolds previously undergoing compression, were scanned by micro computed tomography (mu CT) to identify any architectural difference. Eventually, to clarify the contribution given by differences in the architecture to the standard deviation of Ea, their mechanical response was qualitatively compared to a compact reference material such as polydimethylsiloxane (PDMS). This study links the geometry, architecture and mechanical response to compression of 3D PCL scaffolds and shows the importance of controlling such parameters in the manufacturing process to obtain scaffolds that can be used in vitro or in vivo under reproducible conditions. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:478 / 489
页数:12
相关论文
共 31 条
[1]   Properties of thermoplastic blends: starch-polycaprolactone [J].
Averous, L ;
Moro, L ;
Dole, P ;
Fringant, C .
POLYMER, 2000, 41 (11) :4157-4167
[2]  
Chasin M., 1990, BIODEGRADABLE POLYM
[3]  
Chen GP, 2002, MACROMOL BIOSCI, V2, P67, DOI 10.1002/1616-5195(20020201)2:2<67::AID-MABI67>3.0.CO
[4]  
2-F
[5]   Additive manufacturing in biomedical sciences and the need for definitions and norms [J].
Chhaya, Mohit P. ;
Poh, Patrina S. P. ;
Balmayor, Elizabeth R. ;
van Griensven, Martijn ;
Schantz, Jan-Thorsten ;
Hutmacher, Dietmar W. .
EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (05) :537-543
[6]   Material properties in unconfined compression of human nucleus pulposus, injectable hyaluronic acid-based hydrogels and tissue engineering scaffolds [J].
Cloyd, Jordan M. ;
Malhotra, Neil R. ;
Weng, Lihui ;
Chen, Weiliam ;
Mauck, Robert L. ;
Elliott, Dawn M. .
EUROPEAN SPINE JOURNAL, 2007, 16 (11) :1892-1898
[7]   Matrix elasticity directs stem cell lineage specification [J].
Engler, Adam J. ;
Sen, Shamik ;
Sweeney, H. Lee ;
Discher, Dennis E. .
CELL, 2006, 126 (04) :677-689
[8]  
Gama B.A., 2004, Appl Mech Rev, V57, P223, DOI [10.1115/1.1704626, DOI 10.1115/1.1704626]
[9]   Dynamic mechanical behavior of starch-based scaffolds in dry and physiologically simulated conditions:: Effect of porosity and pore size [J].
Ghosh, Satyabrata ;
Gutierrez, Victor ;
Fernandez, Carolina ;
Rodriguez-Perez, Miguel A. ;
Viana, Julio C. ;
Reis, Rui L. ;
Mano, Joao F. .
ACTA BIOMATERIALIA, 2008, 4 (04) :950-959
[10]   Porous scaffold design for tissue engineering [J].
Hollister, SJ .
NATURE MATERIALS, 2005, 4 (07) :518-524