Image-guided navigation of single-element focused ultrasound transducer

被引:37
作者
Kim, Hyungmin [1 ,2 ]
Chiu, Alan [1 ]
Park, Shinsuk [2 ]
Yoo, Seung-Schik [1 ,3 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Korea Univ, Dept Mech Engn, Seoul, South Korea
[3] Ulsan Natl Inst Sci & Technol, Sch Nanobiosci & Chem Engn, Ulsan, South Korea
基金
新加坡国家研究基金会;
关键词
focused ultrasound; image-guidance; optical tracking; calibration; neuromodulation; brain; single-element transducer; GEOMETRIC DISTORTION; PULSED ULTRASOUND; BRAIN; INTENSITY; DELIVERY; SURGERY; SYSTEM;
D O I
10.1002/ima.22020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The spatial specificity and controllability of focused ultrasound (FUS), in addition to its ability to modify the excitability of neural tissue, allows for the selective and reversible neuromodulation of the brain function, with great potential in neurotherapeutics. Intraoperative magnetic resonance imaging (MRI) guidance has limitations due to its complicated examination logistics, such as fixation through skull screws to mount the stereotactic frame, simultaneous sonication in the MRI environment, and restrictions in choosing MR-compatible materials. To overcome these limitations, an image-guidance system based on optical tracking and preoperative imaging data is developed, separating the imaging acquisition for guidance and sonication procedure for treatment. Techniques to define the local coordinates of the focal point of sonication are presented. First, mechanical calibration detects the concentric rotational motion of a rigid-body optical tracker, attached to a straight rod mimicking the sonication path, pivoted at the virtual FUS focus. The spatial error presented in the mechanical calibration was compensated further by MRI-based calibration, which estimates the spatial offset between the navigated focal point and the ground-truth location of the sonication focus obtained from a temperature-sensitive MR sequence. MRI-based calibration offered a significant decrease in spatial errors (1.9 +/- 0.8 mm; 57% reduction) compared to the mechanical calibration method alone (4.4 +/- 0.9 mm). Using the presented method, pulse-mode FUS was applied to the motor area of the rat brain, and successfully stimulated the motor cortex. The presented techniques can be readily adapted for the transcranial application of FUS to intact human brain. (c) 2012 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 22, 177184, 2012
引用
收藏
页码:177 / 184
页数:8
相关论文
共 30 条
  • [1] Ultrasonic liposculpturing: Extrapolations from the analysis of in vivo sonicated adipose tissue
    Adamo, C
    Mazzocchi, M
    Rossi, A
    Scuderi, N
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (01) : 220 - 226
  • [2] Characterization, prediction, and correction of geometric distortion in 3 T MR images
    Baldwin, Lesley N.
    Wachowicz, Keith
    Thomas, Steven D.
    Rivest, Ryan
    Fallone, B. Gino
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 388 - 399
  • [3] CHEUNG AY, 1984, CANCER RES, V44, P4736
  • [4] A magnetic resonance imaging-compatible, large-scale array for trans-skull ultrasound surgery and therapy
    Clement, GT
    White, PJ
    King, RL
    McDannold, N
    Hynynen, K
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (08) : 1117 - 1125
  • [5] THE CAVITATION THRESHOLD OF HUMAN TISSUE EXPOSED TO 0.2-MHZ PULSED ULTRASOUND - PRELIMINARY MEASUREMENTS BASED ON A STUDY OF CLINICAL LITHOTRIPSY
    COLEMAN, AJ
    KODAMA, T
    CHOI, MJ
    ADAMS, T
    SAUNDERS, JE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (03) : 405 - 417
  • [6] Coussios CC., 2002, J Acoust Soc Am, V112, P2433, DOI [10.1121/1.4808614, DOI 10.1121/1.4808614]
  • [7] Davis C. S., 2002, STAT METHODS ANAL RE
  • [8] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [9] Functional mapping of the motor cortex of the rat using transdural electrical stimulation
    Fonoff, Erich Talamoni
    Pereira, Jose Francisco, Jr.
    Camargo, Leonardo Valente
    Dale, Camila Squarzoni
    Pagano, Rosana Lima
    Ballester, Gerson
    Teixeira, Manoel Jacobsen
    [J]. BEHAVIOURAL BRAIN RESEARCH, 2009, 202 (01) : 138 - 141
  • [10] AUDITORY RESPONSES IN CATS PRODUCED BY PULSED ULTRASOUND
    FOSTER, KR
    WIEDERHOLD, ML
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (04) : 1199 - 1205