Clinical Utility of Capsule Endoscopy and Double-Balloon Enteroscopy in the Management of Obscure Gastrointestinal Bleeding

被引:53
|
作者
Otani, Koji [1 ]
Watanabe, Toshio [1 ,2 ]
Shimada, Sunao [1 ]
Hosomi, Shuhei [1 ]
Nagami, Yasuaki [1 ]
Tanaka, Fumio [1 ]
Kamata, Noriko [1 ]
Taira, Koichi [1 ]
Yamagami, Hirokazu [1 ]
Tanigawa, Tetsuya [1 ,2 ]
Shiba, Masatsugu [1 ]
Fujiwara, Yasuhiro [1 ,2 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Gastroenterol, Osaka, Japan
[2] Osaka City Univ, Grad Sch Med, Samurai Int GI Res Ctr, Osaka, Japan
关键词
Obscure gastrointestinal bleeding; Capsule endoscopy; Double-balloon enteroscopy; SINGLE-CENTER EXPERIENCE; DIAGNOSTIC YIELD; METAANALYSIS; MICROBIOTA; GUIDELINE;
D O I
10.1159/000484218
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Obscure gastrointestinal bleeding (OGIB) is a common but embarrassing problem for gastroenterologists. Most bleeding lesions associated with OGIB are present in the small intestine and sometimes cannot be identified due to the difficulty associated with physical accessibility. Capsule endoscopy (CE) and double-balloon enteroscopy (DBE) have enabled in the process of diagnosing and have evolved to become approaches to treating OGIB. Summary: CE is a minimally invasive procedure and has a high diagnostic yield in patients with OGIB. DBE offers additional advantage of biopsy collection for pathological diagnosis and therapeutic intervention, but it should be noted that it sometimes causes severe adverse events such as acute pancreatitis, intestinal bleeding, and intestinal perforation. CE should be performed early in the workup course of OGIB. Positive CE findings enhance the diagnostic yield of subsequent DBE, and the effective therapeutic intervention improves the clinical outcomes of OGIB patients. On the contrary, there are no clear guidelines for further investigation of patients with negative CE findings at the present. Although patients in stable general condition may only require follow-up, repeated CE is useful to detect positive findings in patients with evidence of sustained bleeding and progressing anemia. We have revealed that repeated CE has higher positive finding rate than DBE in OGIB patients with negative CE findings in a preliminary study. Key Messages: CE and DBE have complementary roles in the management of OGIB, and the precise timing and proper sequence may be important for the approach to treating OGIB. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:52 / 58
页数:7
相关论文
共 50 条
  • [21] Route selection for double-balloon endoscopy, based on capsule transit time, in obscure gastrointestinal bleeding
    Masanao Nakamura
    Naoki Ohmiya
    Osamu Shirai
    Hiroyuki Takenaka
    Kenji Morishima
    Ryoji Miyahara
    Takafumi Ando
    Osamu Watanabe
    Hiroki Kawashima
    Akihiro Itoh
    Yoshiki Hirooka
    Hidemi Goto
    Journal of Gastroenterology, 2010, 45 : 592 - 599
  • [22] Route selection for double-balloon endoscopy, based on capsule transit time, in obscure gastrointestinal bleeding
    Nakamura, Masanao
    Ohmiya, Naoki
    Shirai, Osamu
    Takenaka, Hiroyuki
    Morishima, Kenji
    Miyahara, Ryoji
    Ando, Takafumi
    Watanabe, Osamu
    Kawashima, Hiroki
    Itoh, Akihiro
    Hirooka, Yoshiki
    Goto, Hidemi
    JOURNAL OF GASTROENTEROLOGY, 2010, 45 (06) : 592 - 599
  • [23] Double-balloon enteroscopy in Ireland in the capsule endoscopy era
    G. Holleran
    B. Hall
    M. Alhinai
    A. Zaheer
    R. Leen
    A. Alakkari
    N. Mahmud
    D. McNamara
    Irish Journal of Medical Science (1971 -), 2015, 184 : 257 - 262
  • [24] The role of double-balloon enteroscopy following capsule endoscopy in diagnosis of obscure Small intestinal diseases
    Min, Chen Tian
    Hua, Xu Li
    Lin, Ji Ying
    Mei, Yang Yan
    Fei, Lu
    Bo, Qian Jun
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2013, 29 (02) : 479 - 484
  • [25] Predictability of capsule endoscopy referred to a tertiary care center for double-balloon enteroscopy
    Goyal, Jatinder
    Kim, Hwasoon
    Khan, Ali S.
    Monkemuller, Klaus
    Peter, Shajan
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2015, 27 (09) : 1052 - 1056
  • [26] Clinical impact of multidetector computed tomography before double-balloon enteroscopy for obscure gastrointestinal bleeding
    Yen, Hsu-Heng
    Chen, Yang-Yuan
    Yang, Chia-Wei
    Liu, Chi-Kuang
    Soon, Maw-Soan
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (07) : 692 - 697
  • [27] Different roles of capsule endoscopy and double-balloon enteroscopy in obscure small intestinal diseases
    Zhi-Hong Zhang
    Chun-Hua Qiu
    Yi Li
    World Journal of Gastroenterology, 2015, (23) : 7297 - 7304
  • [28] Clinical impact of multidetector computed tomography before double-balloon enteroscopy for obscure gastrointestinal bleeding
    Hsu-Heng Yen
    Chia-Wei Yang
    Maw-Soan Soon
    World Journal of Gastroenterology, 2012, (07) : 692 - 697
  • [29] Comparison of Urgent Video Capsule Endoscopy and Urgent Double-Balloon Endoscopy in Massive Obscure Gastrointestinal Bleeding
    Aniwan, Satimai
    Viriyautsahakul, Vichai
    Angsuwatcharakon, Phonthep
    Kongkam, Pradermchai
    Treeprasertsuk, Sombat
    Rerknimitr, Rungsun
    Kullavanijaya, Pinit
    HEPATO-GASTROENTEROLOGY, 2014, 61 (135) : 1990 - 1994
  • [30] Video capsule endoscopy as the initial examination for overt obscure gastrointestinal bleeding can efficiently identify patients who require double-balloon enteroscopy
    Maeda, Yoshimasa
    Moribata, Kosaku
    Deguchi, Hisanobu
    Inoue, Izumi
    Maekita, Takao
    Iguchi, Mikitaka
    Tamai, Hideyuki
    Kato, Jun
    Ichinose, Masao
    BMC GASTROENTEROLOGY, 2015, 15