Isolating plasma from blood using a dielectrophoresis-active hydrophoretic device

被引:79
作者
Yan, Sheng [1 ]
Zhang, Jun [1 ]
Alici, Gursel [1 ]
Du, Haiping [2 ]
Zhu, Yonggang [3 ,4 ]
Li, Weihua [1 ]
机构
[1] Univ Wollongong, Sch Mech Mat & Mechatron Engn, Wollongong, NSW 2522, Australia
[2] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW 2522, Australia
[3] CSIRO Mat Sci & Engn, Clayton, Vic 3169, Australia
[4] Australian Natl Fabricat Facil, Melbourne Ctr Nanofabricat, Clayton, Vic 3168, Australia
关键词
MICROFLUIDIC DEVICE; WHOLE-BLOOD; SEPARATION; PARTICLES; MICROPARTICLES; MICROCHANNEL; CHANNEL; CELLS;
D O I
10.1039/c4lc00343h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Plasma is a complex substance that contains proteins and circulating nucleic acids and viruses that can be utilised for clinical diagnostics, albeit a precise analysis depends on the plasma being totally free of cells. We proposed the use of a dielectrophoresis (DEP)-active hydrophoretic method to isolate plasma from blood in a high-throughput manner. This microfluidic device consists of anisotropic microstructures embedded on the top of the channel which generate lateral pressure gradients while interdigitised electrodes lay on the bottom of the channel which can push particles or cells into a higher level using a negative DEP force. Large and small particles or cells (3 mu m and 10 mu m particles, and red blood cells, white blood cells, and platelets) can be focused at the same time in our DEP-active hydrophoretic device at an appropriate flow rate and applied voltage. Based on this principle, all the blood cells were filtrated from whole blood and then the plasma was extracted with a purity of 94.2% and a yield of 16.5% at a flow rate of 10 mu L min(-1). This solved the challenging problem caused by the relatively low throughput of the DEP based device. Our DEP-active hydrophoretic device is a flexible and tunable system that can control the lateral positions of particles by modulating the external voltages without redesigning and fabricating a new channel, and because it is easy to operate, it is easily compatible with other microfluidic platforms that are used for further detection.
引用
收藏
页码:2993 / 3003
页数:11
相关论文
共 42 条
[1]   Electrokinetic motion of a deformable particle: Dielectrophoretic effect [J].
Ai, Ye ;
Mauroy, Benjamin ;
Sharma, Ashutosh ;
Qian, Shizhi .
ELECTROPHORESIS, 2011, 32 (17) :2282-2291
[2]  
[Anonymous], J APPL PHYS
[3]   An integrated dielectrophoretic chip for continuous bioparticle filtering, focusing, sorting, trapping, and detecting [J].
Cheng, I-Fang ;
Chang, Hsien-Chang ;
Hou, Diana ;
Chang, Hsueh-Chia .
BIOMICROFLUIDICS, 2007, 1 (02)
[4]   Sheathless hydrophoretic particle focusing in a microchannel with exponentially increasing obstacle arrays [J].
Choi, Sunglyoung ;
Park, Je-Kyun .
ANALYTICAL CHEMISTRY, 2008, 80 (08) :3035-3039
[5]   Sheathless focusing of microbeads and blood cells based on hydrophoresis [J].
Choi, Sungyoung ;
Song, Seungjeong ;
Choi, Chulhee ;
Park, Je-Kyun .
SMALL, 2008, 4 (05) :634-641
[6]   Continuous blood cell separation by hydrophoretic filtration [J].
Choi, Sungyoung ;
Song, Seungjeong ;
Choi, Chulhee ;
Park, Je-Kyun .
LAB ON A CHIP, 2007, 7 (11) :1532-1538
[7]   Continuous hydrophoretic separation and sizing of microparticles using slanted obstacles in a microchannel [J].
Choi, Sungyoung ;
Park, Je-Kyun .
LAB ON A CHIP, 2007, 7 (07) :890-897
[8]   Hydrophoretic high-throughput selection of platelets in physiological shear-stress range [J].
Choi, Sungyoung ;
Ku, Taeyun ;
Song, Seungjeong ;
Choi, Chulhee ;
Park, Je-Kyun .
LAB ON A CHIP, 2011, 11 (03) :413-418
[9]   Tuneable hydrophoretic separation using elastic deformation of poly(dimethylsiloxane) [J].
Choi, Sungyoung ;
Park, Je-Kyun .
LAB ON A CHIP, 2009, 9 (13) :1962-1965
[10]   Hydrophoretic Sorting of Micrometer and Submicrometer Particles Using Anisotropic Microfluidic Obstacles [J].
Choi, Sungyoung ;
Song, Seungjeong ;
Choi, Chulhee ;
Park, Je-Kyun .
ANALYTICAL CHEMISTRY, 2009, 81 (01) :50-55