Cationic Conjugated Polyelectrolyte/Molecular Beacon Complex for Sensitive, Sequence-Specific, Real-Time DNA Detection

被引:32
|
作者
Feng, Xuli [1 ]
Duan, Xinrui [1 ]
Liu, Libin [1 ]
An, Lingling [1 ]
Feng, Fude [1 ]
Wang, Shu [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, Ke Lab Organ Solids, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1021/la802932t
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new fluorescence method has been developed for DNA detection at room temperature in a sensitive, selective. economical, and real-time manner that interfaces the superiority of a molecular beacon in mismatch discrimination with the light-harvesting property of water-soluble conjugated polyelectrolytes. The probe solution contains a cationic conjugated polyelectrolyte (PFP-NMe3+), a molecular beacon with a five base pairs double-stranded stem labeled at the 5'-terminus with fluorescein (DNA(P-)Fl), and ethidium bromide (EB, a specific intercalator of dsDNA). The electrostatic interactions between DNA(P)-Fl and PFP-NMe3+ keep them in close proximity, facilitating the fluorescence resonance energy transfer (FRET) from PFP-NMe3+ to fluorescein. Upon adding a complementary strand to the probe Solution, the conformation of DNA(P)-Fl transits into dsDNA followed by the intercalation of EB into the grooves. Two-step FRET, from PFP-NMe3+ to DNA(P)-Fl (FRET-1), followed by FRET from DNA(P)-Fl to EB (FRET-2) takes place. In view of the observed fluorescein or EB emission changes, DNA can be detected in aqueous solution. Because the base mismatch in target DNA inhibits the transition of DNA(P)-Fl from the stem-loop to duplex structure, single nucleotide mismatch can be clearly detected.
引用
收藏
页码:12138 / 12141
页数:4
相关论文
共 50 条
  • [41] Molecular-beacon multiplex real-time PCR assay for detection of Vibrio cholerae
    Gubala, Aneta J.
    Proll, David F.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2006, 72 (09) : 6424 - 6428
  • [42] Real-Time PCR to Study the Sequence Specific Magnetic Purification of DNA
    Peeters, Sara
    Stakenborg, Tim
    Colle, Frederik
    Liu, ChengXun
    Lagae, Liesbet
    Van Ranst, Marc
    BIOTECHNOLOGY PROGRESS, 2010, 26 (06) : 1678 - 1684
  • [43] Cationic Conjugated Polyelectrolytes-Triggered Conformational Change of Molecular Beacon Aptamer for Highly Sensitive and Selective Potassium Ion Detection
    Kim, Boram
    Jung, In Hwan
    Kang, Mijeong
    Shim, Hong-Ku
    Woo, Han Young
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (06) : 3133 - 3138
  • [45] Real-time PCR assay using molecular beacon for quantitation of hepatitis B virus DNA
    Sum, SSM
    Wong, DKH
    Yuen, MF
    Yuan, HJ
    Yu, J
    Lai, CL
    Ho, D
    Zhang, LQ
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (08) : 3438 - 3440
  • [46] Real-time Monitoring Continuous Replication of DNA Leading Strand in vitro Based on Molecular Beacon
    Meng Xiang-Xian
    Yang Xiao-Hai
    Wang Ke-Min
    Guo Qiu-Ping
    Li Jun
    Tang Zhi-Wen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2009, 30 (08): : 1538 - 1542
  • [47] Sequence-specific recognition of double-stranded DNA with molecular beacon with the aid of Ag+ under neutral pH environment
    Xiao, Zhiyou
    Guo, Xiaoting
    Ling, Liansheng
    CHEMICAL COMMUNICATIONS, 2013, 49 (34) : 3573 - 3575
  • [48] A real-time characterization method to rapidly optimize molecular beacon signal for sensitive nucleic acids analysis
    Hsieh, Albert Tsung-Hsi
    Pan, Patrick J.
    Lee, Abraham P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (13) : 3059 - 3067
  • [49] A real-time characterization method to rapidly optimize molecular beacon signal for sensitive nucleic acids analysis
    Albert Tsung-Hsi Hsieh
    Patrick J. Pan
    Abraham P. Lee
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3059 - 3067
  • [50] Detection of Listeria monocytogenes in fresh produce using molecular beacon -: Real-time PCR technology
    Liming, SH
    Zhang, Y
    Meng, J
    Bhagwat, AA
    JOURNAL OF FOOD SCIENCE, 2004, 69 (08) : M240 - M245