Cationic Conjugated Polyelectrolyte/Molecular Beacon Complex for Sensitive, Sequence-Specific, Real-Time DNA Detection

被引:32
|
作者
Feng, Xuli [1 ]
Duan, Xinrui [1 ]
Liu, Libin [1 ]
An, Lingling [1 ]
Feng, Fude [1 ]
Wang, Shu [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, Ke Lab Organ Solids, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1021/la802932t
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new fluorescence method has been developed for DNA detection at room temperature in a sensitive, selective. economical, and real-time manner that interfaces the superiority of a molecular beacon in mismatch discrimination with the light-harvesting property of water-soluble conjugated polyelectrolytes. The probe solution contains a cationic conjugated polyelectrolyte (PFP-NMe3+), a molecular beacon with a five base pairs double-stranded stem labeled at the 5'-terminus with fluorescein (DNA(P-)Fl), and ethidium bromide (EB, a specific intercalator of dsDNA). The electrostatic interactions between DNA(P)-Fl and PFP-NMe3+ keep them in close proximity, facilitating the fluorescence resonance energy transfer (FRET) from PFP-NMe3+ to fluorescein. Upon adding a complementary strand to the probe Solution, the conformation of DNA(P)-Fl transits into dsDNA followed by the intercalation of EB into the grooves. Two-step FRET, from PFP-NMe3+ to DNA(P)-Fl (FRET-1), followed by FRET from DNA(P)-Fl to EB (FRET-2) takes place. In view of the observed fluorescein or EB emission changes, DNA can be detected in aqueous solution. Because the base mismatch in target DNA inhibits the transition of DNA(P)-Fl from the stem-loop to duplex structure, single nucleotide mismatch can be clearly detected.
引用
收藏
页码:12138 / 12141
页数:4
相关论文
共 50 条
  • [21] Sensitive sequence-specific molecular identification system comprising an aluminum micro-nanofluidic chip and associated real-time confocal detector
    Huang, Guoliang
    Wang, Can
    Ma, Li
    Yang, Xu
    Yang, Xiaoyong
    Wang, Guoqing
    ANALYTICA CHIMICA ACTA, 2011, 695 (1-2) : 1 - 10
  • [22] Homogeneous and sensitive DNA detection based on polyelectrolyte complexes of cationic conjugated poly(pyridinium salt)s and DNA
    Han, Fengli
    Lu, Yan
    Zhang, Qiang
    Sun, Jingfen
    Zeng, Xianshun
    Li, Chenxi
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (09) : 4106 - 4112
  • [23] A thymidine-terminated molecular beacon for selective Hg2+ or sequence-specific DNA assay
    Hou, Peng
    Long, Yunfei
    Zhao, Jin
    Wang, Jianxiu
    Zhou, Feimeng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 86 : 76 - 79
  • [24] Molecular beacon based biosensor for the sequence-specific detection of DNA using DNA-capped gold nanoparticles-streptavidin conjugates for signal amplification
    Fang, Xian
    Jiang, Wei
    Han, Xiaowei
    Zhang, Yuzhong
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1271 - 1277
  • [25] Quantitative analysis of DNA methylation using sequence-specific, real-time loop-mediated isothermal amplification
    Fu, Yao
    Zhang, Li
    Xing, Yu
    Deng, Shixiong
    ANALYTICA CHIMICA ACTA, 2022, 1235
  • [26] A molecular beacon strategy for real-time monitoring of triplex DNA formation kinetics
    Antony, T
    Subramaniam, V
    ANTISENSE & NUCLEIC ACID DRUG DEVELOPMENT, 2002, 12 (03): : 145 - 154
  • [27] Molecular beacon based biosensor for the sequence-specific detection of DNA using DNA-capped gold nanoparticles-streptavidin conjugates for signal amplification
    Xian Fang
    Wei Jiang
    Xiaowei Han
    Yuzhong Zhang
    Microchimica Acta, 2013, 180 : 1271 - 1277
  • [28] Highly sensitive detection of sequence-specific DNA with morpholino-functionalized magnetic microspheres
    Hu, Weiwen
    Ning, Yong
    Li, Lianzhi
    Kong, Jinming
    Zhang, Xueji
    ANALYTICAL METHODS, 2015, 7 (16) : 6712 - 6717
  • [29] High sensitive electrochemical detection of sequence-specific DNA using low current voltammetry
    Lin, Lingling
    Zhou, Jianzhang
    Zhang, Yan
    Lin, Zhonghua
    ELECTROANALYSIS, 2008, 20 (16) : 1798 - 1804
  • [30] PNA-based light-up probes for real-time detection of sequence-specific PCR products
    Wolffs, P
    Knutsson, R
    Sjöback, R
    Rådström, P
    BIOTECHNIQUES, 2001, 31 (04) : 766 - +