Improvement of micro-vibration of a two-stage Stirling cryocooler

被引:8
作者
Otsuka, Kiyomi [1 ]
Kanao, Ken'ichi [1 ]
Tsunematsu, Shoji [1 ]
Narasaki, Katsuhiro [1 ]
Hiratsuka, Yoshikatsu [2 ]
Yamasaki, Noriko [3 ]
Mitsuda, Kazuhisa [3 ]
Nakagawa, Takao [3 ]
Shinozaki, Keisuke [4 ]
Sato, Yoichi [4 ]
机构
[1] Sumitomo Heavy Ind Ltd, Ind Equipment Div, 5-2 Sobiraki Cho, Niihama, Ehime 7928588, Japan
[2] Sumitomo Heavy Ind Ltd, Technol Res Ctr, 19 Natsushima Cho, Yokosuka, Kanagawa 2378555, Japan
[3] JAXA, Inst Space & Astronaut Sci, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
[4] JAXA, Res & Dev Directorate, 2-1-1 Sengen, Tsukuba, Ibaraki 3058505, Japan
关键词
Flexure bearing; Microvibration; Space cryogenics; Stirling cooler;
D O I
10.1016/j.cryogenics.2020.103133
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-stage Stirling cryocoolers (2ST cooler) produced by Sumitomo Heavy Industries, Ltd. have been launched into orbit on three satellites: the "AKARI (ASTRO-F)" infrared astronomical satellite, JEM/SMILES on ISS, and the "HITOMI (ASTRO-H)" X-ray astronomical satellite. A 2ST cooler compressor has a linear-ball-bearing system as a piston-supporting structure. The linear ball bearing system is a key components to realize a lower drive frequency (15 Hz), a long piston stroke (30 mm). Its typical cooling power is 200 mW at 20 K for the second stage and 1000 mW at 100 K for the first stage, with 90 W electrical input power. During the test of the "HITOMI" engineering model, the energy resolution of the detector was found to be degraded when cryocoolers were in operation. After investigation, it was found that micro vibration from 2STs caused the degradation. The continuum in the vibration spectrum propagated into sub-Kelvin region and generated thermal noise. The continuum has origin in linear ball bearing in the compressor. In the case of "HITOMI", vibration isolators were introduced to resolve this issue. For future mission, we are required to reduce microvibration of cryocooler itself. Therefore, the piston support mechanism in the compressor was modified from linear ball bearings to triangle shape flexure springs in order to reduce the continuum in vibration spectrum. In order to achieve a long piston stroke (+/- 15 mm), the generated stress could be reduced to 400 MPa (Less than 1/2 of fatigue limit) or less even when the shape of the triangle shape flexure spring was devised and displaced by 15 mm. The typical vibration level has been reduced to 1 x 10(-5) Nrms(2)/ Hz or less at a frequency of 200 Hz or less and 1/10 times or less at 200-600 Hz than that of a compressor with a linear ball bearing system. The cooling power is kept to 260 mW at 20 K, with 90 W electrical input power. This low vibration cooler is expected to be an improved cryogenic system for use in future projects with sub-Kelvin detectors.
引用
收藏
页数:9
相关论文
共 9 条
  • [1] Ezoe Y, 2019, P 28 SPAC CRYOG WORK
  • [2] Flight performance of the AKARI cryogenic system
    Nakagawa, Takao
    Enya, Keigo
    Hirabayashi, Masayuki
    Kaneda, Hidehiro
    Kii, Tsuneo
    Kimura, Yoshiyuki
    Matsumoto, Toshio
    Murakami, Hiroshi
    Murakami, Masahide
    Narasaki, Katsuhiro
    Narita, Masanao
    Ohnishi, Akira
    Tsunematsu, Shoji
    Yoshida, Seiji
    [J]. PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2007, 59 (sp2) : S377 - S387
  • [3] Narasaki K, 2004, AIP CONF PROC, V710, P1428, DOI 10.1063/1.1774835
  • [4] Narasaki K, ADV CRYOGENIC ENG, V49B, P1785
  • [5] Ochiai S., 2010, P 21 INT S SPAC THZ, P179
  • [6] Sato Y, 2008, Cryocoolers, V15, P13
  • [7] Development status of the mechanical cryocoolers for the Soft X-ray Spectrometer on board Astro-H
    Sato, Yoichi
    Sawada, Kenichiro
    Shinozaki, Keisuke
    Sugita, Hiroyuki
    Nishibori, Toshiyuki
    Sato, Ryota
    Mitsuda, Kazuhisa
    Yamasaki, Noriko Y.
    Takei, Yoh
    Goto, Ken
    Nakagawa, Takao
    Fujimoto, Ryuichi
    Kikuchi, Kenichi
    Murakami, Masahide
    Tsunematsu, Shoji
    Ootsuka, Kiyomi
    Kanao, Kenichi
    Narasaki, Katsuhiro
    [J]. CRYOGENICS, 2014, 64 : 182 - 188
  • [8] Vibration isolation system for cryocoolers of soft x-ray spectrometer on-board ASTRO-H (Hitomi)
    Takei, Yoh
    Yasuda, Susumu
    Ishimura, Kosei
    Iwata, Naoko
    Okamoto, Atsushi
    Sato, Yoichi
    Ogawa, Mina
    Sawada, Makoto
    Kawano, Taro
    Obara, Shingo
    Natsukari, Chikara
    Wada, Atsushi
    Yamada, Shinya
    Fujimoto, Ryuichi
    Kokubun, Motohide
    Yamasaki, Noriko Y.
    Sugita, Hiroyuki
    Minesugi, Kenji
    Nakamura, Yasuo
    Mitsuda, Kazuhisa
    Takahashi, Tadayuki
    Yoshida, Seiji
    Tsunematsu, Shoji
    Kanao, Kenichi
    Narasaki, Katsuhiro
    Otsuka, Kiyomi
    Porter, F. Scott
    Kilbourne, Caroline A.
    Chiao, Meng P.
    Eckart, Megan E.
    Sneiderman, Gary A.
    Pontius, James T.
    McCammon, Dan
    Wilke, Paul
    Basile, John
    [J]. JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (01)
  • [9] In-orbit performance of a helium dewar for the soft X-ray spectrometer onboard ASTRO-H
    Yoshida, Seiji
    Miyaoka, Mikio
    Kanao, Ken'ichi
    Tsunematsu, Shoji
    Otsuka, Kiyomi
    Hoshika, Shunji
    Narasaki, Katsuhiro
    Mitsuda, Kazuhisa
    Yamasaki, Noriko
    Takei, Yoh
    Fujimoto, Ryuichi
    Ezoe, Yuichiro
    Sato, Yoichi
    Okarnoto, Atsushi
    Noda, Hirofumi
    DiPirro, Michael
    Shirron, Peter
    [J]. CRYOGENICS, 2018, 91 : 27 - 35