A Novel Approach to Prepare a Glass-Fiber-Packed Capillary Column for Capillary Electrochromatography

被引:2
作者
Shi, Zhi-Guo [1 ]
Wei, Fang [1 ]
Feng, Yu-Qi [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
CEC; Fast analysis; Glass fiber; Packing technology;
D O I
10.1080/10826070802480008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, a novel method was proposed to pack long glass fibers into a narrow-bore capillary for capillary electrochromatography (CEC) applications. The factors that influence the packing process were studied in detail. The results demonstrated that solvents played dual roles to introduce the glass fiber into the capillary during the packing process, a lubricant and a carrying reagent. A preliminary CEC performance, between a glass fiber-packed-C-18-bonded open tubular column and a C-18-bonded open tubular one, was compared. The former exhibited a 25-60% larger electroosmotic flow (EOF) than that of the latter. High separation efficiency of toluene and naphthalene was obtained on the fiber-packed column, while the separation time decreased about 19%. The glass fiber-packed column showed a promising perspective in CEC applications, due to its high EOF, relative low phase ratio, ease of preparation, and tunable selectivity.
引用
收藏
页码:3094 / 3104
页数:11
相关论文
共 27 条
[1]   Overview of capillary electrophoresis and capillary electrochromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :443-463
[2]   Chemically L-phenylalaninamide-modified monolithic silica column prepared by a sol-gel process far enantioseparation of dansyl amino acids by ligand exchange-capillary electrochromatography [J].
Chen, ZL ;
Hobo, T .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3348-3357
[3]   Photopolymerized sol-gel monoliths for capillary electrochromatography [J].
Dulay, MT ;
Quirino, JP ;
Bennett, BD ;
Kato, M ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3921-3926
[4]   Recent applications in capillary electrochromatography [J].
Eeltink, S ;
Rozing, GR ;
Kok, WT .
ELECTROPHORESIS, 2003, 24 (22-23) :3935-3961
[5]   Recent highlights in stationary phase design for open-tubular capillary electrochromatography [J].
Guihen, E ;
Glennon, JD .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :67-81
[6]   Sol-gel monolithic columns with reversed electroosmotic flow for capillary electrochromatography [J].
Hayes, JD ;
Malik, A .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4090-4099
[7]   Standard and capillary chromatography, including electrochromatography, on continuous polymer beds (monoliths), based on water-soluble monomers [J].
Hjertén, S .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (04) :1205-1214
[8]   Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry [J].
Huang, XA ;
Zhang, S ;
Schultz, GA ;
Henion, J .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2336-2344
[9]   Preparation and chromatographic application of macroporous silicate in a capillary [J].
Ishizuka, N ;
Nakanishi, K ;
Hirao, K ;
Tanaka, N .
JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2000, 19 (1-3) :371-375
[10]   Fibrous stationary phase in capillary electrochromatography [J].
Jinno, K ;
Watanabe, H ;
Kiso, Y .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 48 (03) :209-218