MIT-Skywalker: A Novel Gait Neurorehabilitation Robot for Stroke and Cerebral Palsy

被引:35
作者
Susko, Tyler [1 ,2 ]
Swaminathan, Krithika [1 ]
Krebs, Hermano Igo [1 ,3 ,4 ,5 ,6 ]
机构
[1] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[2] Univ Calif Santa Barbara, Dept Mech Engn, Santa Barbara, CA 93106 USA
[3] Univ Maryland, Sch Med, Dept Neurol, Baltimore, MD 21201 USA
[4] Fujita Hlth Univ, Dept Phys Med & Rehabil, Nagoya, Aichi 4701192, Japan
[5] Newcastle Univ, Inst Neurosci, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[6] Osaka Univ, Dept Mech Sci & Bioengn, Suita, Osaka 5650871, Japan
关键词
Cerebral palsy; gait; rehabilitation robotics; stroke; walking; ASSISTED THERAPY; IMPROVE WALKING; TREADMILL; REHABILITATION; TRAINER; PLATFORM; BALANCE; RESTORATION; IMPAIRMENTS; PREVALENCE;
D O I
10.1109/TNSRE.2016.2533492
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The MIT-Skywalker is a novel robotic device developed for the rehabilitation or habilitation of gait and balance after a neurological injury. It represents an embodiment of the concept exhibited by passive walkers for rehabilitation training. Its novelty extends beyond the passive walker quintessence to the unparalleled versatility among lower extremity devices. For example, it affords the potential to implement a novel training approach built upon our working model of movement primitives based on submovements, oscillations, and mechanical impedances. This translates into three distinct training modes: discrete, rhythmic, and balance. The system offers freedom of motion that forces self-directed movement for each of the three modes. This paper will present the technical details of the robotic system as well as a feasibility study done with one adult with stroke and two adults with cerebral palsy. Results of the one-month feasibility study demonstrated that the device is safe and suggested the potential advantages of the three modular training modes that can be added or subtracted to tailor therapy to a particular patient's need. Each participant demonstrated improvement in common clinical and kinematic measurements that must be confirmed in larger randomized control clinical trials.
引用
收藏
页码:1089 / 1099
页数:11
相关论文
共 50 条
[1]   The effect of robot-assisted therapy and rehabilitative training on motor recovery following stroke [J].
Aisen, ML ;
Krebs, HI ;
Hogan, N ;
McDowell, F ;
Volpe, BT .
ARCHIVES OF NEUROLOGY, 1997, 54 (04) :443-446
[2]   A kinematic comparison of overground and treadmill walking [J].
Alton, F ;
Baldey, L ;
Caplan, S ;
Morrissey, MC .
CLINICAL BIOMECHANICS, 1998, 13 (06) :434-440
[3]  
Altshuller GS, 1999, INNOVATION ALGORITHM
[4]  
[Anonymous], NEUROREHAB NEURAL RE
[5]  
[Anonymous], MIT SKYWALKER NOVEL
[6]  
[Anonymous], J BIOMECH
[7]  
[Anonymous], GAIT ANAL NORMAL PAT
[8]  
[Anonymous], P 40 ANN NE BIOENG C
[9]   On the Control of the MIT-Skywalker [J].
Artemiadis, Panagiotis K. ;
Krebs, Hermano Igo .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :1287-1291
[10]   Active Leg Exoskeleton (ALEX) for gait rehabilitation of motor-impaired patients [J].
Banala, Sai K. ;
Agrawal, Suni K. ;
Scholz, John P. .
2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, :401-+