Low dose contrast CT for transcatheter aortic valve replacement assessment: Results from the prospective SPECTACULAR study (spectral CT assessment prior to TAVR)

被引:21
作者
Cavallo, Armando Ugo [1 ,2 ]
Patterson, Andrew J. [1 ]
Thomas, Rahul [1 ]
Alaiti, Mohamad Amer [1 ]
Attizzani, Guilherme F. [1 ]
Laukamp, Kai [1 ,3 ]
Hokamp, Nils Grosse [3 ]
Bezerra, Hiram [1 ]
Gilkeson, Robert [1 ]
Rajagopalan, Sanjay [1 ]
机构
[1] Case Western Reserve Univ, Univ Hosp, Harrington Heart & Vasc Inst, Dept Med & Radiol, Cleveland, OH 44106 USA
[2] Univ Hosp Policlin Tor Vergata, Div Radiol, Rome, Italy
[3] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Cologne, Germany
关键词
Aortic valve stenosis; Transcutaneous aortic valve replacement (TAVR); Spectral CT; 40; KeV; Conventional polychromatic 120 kV; MULTIDETECTOR COMPUTED-TOMOGRAPHY; DUAL-SOURCE CT; OUTCOMES; RECONSTRUCTIONS; ROOT;
D O I
10.1016/j.jcct.2019.06.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Computed tomographic angiography (CTA) based planning for transcatheter aortic valve replacement (TAVR) is essential for reduction of periprocedural complications. Spectral CT based imaging provides several advantages, including better contrast/signal to noise ratio and increased soft tissue contrast, permitting better delineation of contrast filled structures at lower doses of iodinated contrast media. The aim of this prospective study was to assess the initial feasibility of a low dose iodinated contrast protocol, utilizing monoenergetic 40 keV reconstruction, using a dual-layer CT scanner (DLCT) for CTA in patients undergoing TAVR planning. Methods: 116 consecutive TAVR patients underwent a gated chest and a non-gated CTA of the abdomen and pelvis. 40 keV virtual monoenergetic images (VMI) were reconstructed and compared with conventional polychromatic images (CI). The proximal aorta and access vessels were scored for image quality by independent experienced cardiovascular imagers. Results: Proximal aortic image quality as assessed by signal to noise (SNR) and contrast to noise ratio (CNR), were significantly better with 40 keV VMI relative to CI (SNR 14.65 +/- 7.37 vs 44.16 +/- 22.39, p < 0.001; CNR 15.84 +/- 9.93 vs 59.8 +/- 40.83, p < 0.001). Aortic root dimensions were comparable between the two approaches with a bias towards higher measurements at 40 keV (Bland Altman). SNR and CNR in all access vessel segments at 40 keV were substantially better (p < 0.001 for all peripheral access vessel segments) with comparable image quality. Conclusion: 40 keV VMI with low dose contrast dose spectral imaging is feasible for comprehensive pre-procedural evaluation of access vessels and measurements of aortic root dimensions in patients undergoing TAVR.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 33 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Predictors of Poor Outcomes After Transcatheter Aortic Valve Replacement Results From the PARTNER (Placement of Aortic Transcatheter Valve) Trial [J].
Arnold, Suzanne V. ;
Reynolds, Matthew R. ;
Lei, Yang ;
Magnuson, Elizabeth A. ;
Kirtane, Ajay J. ;
Kodali, Susheel K. ;
Zajarias, Alan ;
Thourani, Vinod H. ;
Green, Philip ;
Rodes-Cabau, Josep ;
Beohar, Nirat ;
Mack, Michael J. ;
Leon, Martin B. ;
Cohen, David J. .
CIRCULATION, 2014, 129 (25) :2682-2690
[3]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[4]   The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial [J].
Binder, Ronald K. ;
Webb, John G. ;
Willson, Alexander B. ;
Urena, Marina ;
Hansson, Nicolaj C. ;
Norgaard, Bjarne L. ;
Pibarot, Philippe ;
Barbanti, Marco ;
Larose, Eric ;
Freeman, Melanie ;
Dumont, Eric ;
Thompson, Chris ;
Wheeler, Miriam ;
Moss, Robert R. ;
Yang, Tae-hyun ;
Pasian, Sergio ;
Hague, Cameron J. ;
Giang Nguyen ;
Raju, Rekha ;
Toggweiler, Stefan ;
Min, James K. ;
Wood, David A. ;
Rodes-Cabau, Josep ;
Leipsic, Jonathon .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) :431-438
[5]   Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) :1-20
[6]   CT in Transcatheter Aortic Valve Replacement [J].
Blanke, Philipp ;
Schoepf, U. Joseph ;
Leipsic, Jonathon A. .
RADIOLOGY, 2013, 269 (03) :650-669
[7]   Combined Assessment of Aortic Root Anatomy and Aortoiliac Vasculature With Dual-Source CT as a Screening Tool in Patients Evaluated for Transcatheter Aortic Valve Implantation [J].
Blanke, Philipp ;
Euringer, Wulf ;
Baumann, Tobias ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :872-881
[8]   Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging [J].
Doerner, Jonas ;
Hauger, Myriam ;
Hickethier, Tilman ;
Byrtus, Jonathan ;
Wybranski, Christian ;
Hokamp, Nils Grosse ;
Maintz, David ;
Haneder, Stefan .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 :52-58
[9]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[10]   Mortality associated with nephropathy after radiographic contrast exposure [J].
From, Aaron M. ;
Bartholmai, Brian J. ;
Williams, Amy W. ;
Cha, Stephen S. ;
Mcdonald, Furman S. .
MAYO CLINIC PROCEEDINGS, 2008, 83 (10) :1095-1100