All metal implants in human bodies corrode which results in metal ions release. This is not necessarily a problem and represents for most patients no hazard. However, if a critical metal ion concentration is exceeded, local or rarely systemic problems can occur. This article summarizes the mechanisms of metal ion release and its clinical consequences. Several situations can result in increased metal ion release: metal-on-metal hip arthroplasties with increased wear, increased micromotion at taper interfaces, direct metal-metal contact (polyethylene wear, impingement), erroneously used metal heads after ceramic head fracture. Possible problems are in most cases located close to the concerned joint. Furthermore, there are reports about toxic damage to several organs. Most of these reports refer to erroneously used metal heads in revisions after a broken ceramic head. There is currently no evidence of carcinogenic or teratogenic effects of implants but data is not sufficient to exclude possible effects. Cobalt and chromium blood levels (favorably in whole blood) should be measured in patients with suspected elevated metal ions. According to current knowledge levels below 2 mu g/l seem to be uncritical, levels between 2 and 7 mu g/l are considered borderline with unknown biological consequences and levels above 7 mu g/l indicate a local problem which should be further diagnosed. Metal ion levels always need to be interpreted together with clinical symptoms and imaging results.
引用
收藏
页码:369 / 381
页数:13
相关论文
共 68 条
  • [1] Aksakal B., 2004, J FAIL ANAL PREV, V4, P17, DOI [10.1007/s11668-996-0007-9, DOI 10.1007/S11668-996-0007-9]
  • [2] The effect of platform switching on the levels of metal ion release from different implant-abutment couples
    Alrabeah, Ghada O.
    Knowles, Jonathan C.
    Petridis, Haralampos
    [J]. INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2016, 8 (02) : 117 - 125
  • [3] Trunnion corrosion WHAT SURGEONS NEED TO KNOW IN 2018
    Berstock, J. R.
    Whitehouse, M. R.
    Duncan, C. P.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (01) : 44 - 49
  • [4] Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings
    Bishop, Nicholas
    Witt, Florian
    Pourzal, Robin
    Fischer, Alfons
    Ruetschi, Marcel
    Michel, Markus
    Morlock, Michael
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) : 1116 - 1122
  • [5] High Prevalence of Pseudotumors in Patients with a Birmingham Hip Resurfacing Prosthesis A Prospective Cohort Study of One Hundred and Twenty-nine Patients
    Bisschop, R.
    Boomsma, M. F.
    Van Raay, J. J. A. M.
    Tiebosch, A. T. M. G.
    Maas, M.
    Gerritsma, C. L. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (17) : 1554 - 1560
  • [6] Black J., 1988, Orthopaedic biomaterials in research and practice
  • [7] Risk of cancer following primary total hip replacement or primary resurfacing arthroplasty of the hip: a retrospective cohort study in Scotland
    Brewster, D. H.
    Stockton, D. L.
    Reekie, A.
    Ashcroft, G. P.
    Howie, C. R.
    Porter, D. E.
    Black, R. J.
    [J]. BRITISH JOURNAL OF CANCER, 2013, 108 (09) : 1883 - 1890
  • [8] Changes in Early Serum Metal Ion Levels and Impact on Liver, Kidney, and Immune Markers Following Metal-on-Metal Total Hip Arthroplasty
    Chen, Zhefeng
    Wang, Zhen
    Wang, Qing
    Cui, Weiding
    Liu, Feng
    Fan, Weimin
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (03) : 612 - 616
  • [9] Toxicology-based cancer causation analysis of CoCr-containing hip implants: a quantitative assessment of genotoxicity and tumorigenicity studies
    Christian, Whitney V.
    Oliver, Lindsay D.
    Paustenbach, Dennis J.
    Kreider, Marisa L.
    Finley, Brent L.
    [J]. JOURNAL OF APPLIED TOXICOLOGY, 2014, 34 (09) : 939 - 967
  • [10] AN INVESTIGATION INTO THE CORRELATION BETWEEN THE ELECTRICAL POTENTIALS OF METALS AND THEIR BEHAVIOUR IN BIOLOGICAL FLUIDS
    CLARKE, EGC
    HICKMAN, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1953, 35 (03): : 467 - 473