Amputee Locomotion: Determining the Inertial Properties of Running-Specific Prostheses

被引:25
作者
Baum, Brian S. [1 ]
Schultz, Melanie P. [1 ]
Tian, Andrea [1 ]
Shefter, Benjamin [2 ]
Wolf, Erik J. [3 ]
Kwon, Hyun Joon [1 ]
Shim, Jae Kun [1 ,4 ,5 ,6 ]
机构
[1] Univ Maryland, Dept Kinesiol, College Pk, MD 20742 USA
[2] Univ Maryland, Dept Mat Engn, College Pk, MD 20742 USA
[3] Walter Reed Natl Mil Med Ctr, Bethesda, MD USA
[4] Univ Maryland, Dept Bioengn, College Pk, MD 20742 USA
[5] Univ Maryland, Neurosci & Cognit Sci Grad Program, College Pk, MD 20742 USA
[6] Kyung Hee Univ, Dept Mech Engn, Yongin, South Korea
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2013年 / 94卷 / 09期
关键词
Amputation; Prostheses and implants; Rehabilitation; TRANSTIBIAL AMPUTEES; MASS-DISTRIBUTION; JOINT MOMENTS; GAIT; KINEMATICS; MODELS;
D O I
10.1016/j.apmr.2013.03.010
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: (1) To test the validity of a trifilar pendulum in estimating moments of inertia (MOIs) for running-specific prostheses (RSPs), (2) to measure inertial properties (mass, center of mass [CM] position, and MOIs) for 4 RSPs, (3) to verify the influence of the stiffness on the inertial properties of RSPs, and (4) to develop a predictive equation to estimate RSP CM positions. Design: An aluminum block with known MOIs was used for verifying the accuracy of the trifilar pendulum MOI measurements. MOI errors were investigated by systematically misaligning the block and pendulum principal axes across a range of 1 to 10cm. Mass, CM position, and MOI were tested across 4 RSP designs with 3 stiffness categories each. Setting: University biomechanics laboratory. Specimens: Four different RSP designs and 3 stiffness categories per design were examined. Interventions: Not applicable. Main Outcome Measures: MOI errors from known values and principal axis misalignments between RSPs and pendulum; mass, CM positions, and RSP principal axis MOIs; and predictive equation CM position errors. Results: The trifilar pendulum estimated MOIs within -6.21 x 10(-5)kg/m(2) (<= 1% error) for a block with known MOIs. Misalignments of 1 to 5cm between the RSPs' and pendulum's CM yielded errors from .00002 to .00113 kg/m(2) (0.3%-59.2%). Each RSP's inertial properties are presented. MOIs about any axis varied <.004kg/m(2) across stiffness categories; MOIs differed up to .013kg/m(2) between different designs. The predictive CM equation erred between .010 and .028m when using average input values across an RSP design. Conclusions: Trifilar pendulums can accurately measure RSP MOI. The RSP inertial properties differed slightly across stiffness categories within each design, but differed more substantially across different RSP designs. Using a predictive equation to estimate RSP CM positions can provide adequate data, but directly measuring CM positions is preferable. (C) 2013 by the American Congress of Rehabilitation Medicine
引用
收藏
页码:1776 / 1783
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 1975, AMRTR74137
[2]  
Bruggemann G.-P., 2009, SPORTS TECHNOLOGY, V1, P220, DOI DOI 10.1080/19346182.2008.9648476
[3]  
Clauser CE, 1969, AMRLTR6970 WRIGHT PA
[4]   Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters [J].
de Leva, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1223-1230
[5]  
Dempster W.T., 1955, WADCTR55159 WRIGHT P
[6]   Error Analysis in Trifilar Inertia Measurements [J].
du Bois, J. L. ;
Lieven, N. A. J. ;
Adhikari, S. .
EXPERIMENTAL MECHANICS, 2009, 49 (04) :533-540
[7]  
Genta G., 1994, Meccanica, V29, P125, DOI 10.1007/BF01007497
[8]   The effect of direct measurement versus cadaver estimates of anthropometry in the calculation of joint moments during above-knee prosthetic gait in pediatrics [J].
Goldberg, Evan J. ;
Requejo, Philip S. ;
Fowler, Eileen G. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :695-700
[9]   Mechanical Analysis of Diving [J].
Groves, William H. .
RESEARCH QUARTERLY, 1950, 21 (02) :132-144
[10]  
Hay J.G., 1985, BIOMECHANICS SPORTS