Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling

被引:9
作者
Adhikari, Khem Bahadur [1 ]
Rohde, Morten [2 ]
Velschow, Sten [2 ]
Feldt-Rasmussen, Ulla [3 ,4 ]
Johannesen, Jesper [4 ,5 ]
Johnsen, Anders Holten [1 ]
机构
[1] Rigshosp, Dept Clin Biochem, KB3011, Copenhagen, Denmark
[2] Fluisense ApS, Lillerod, Denmark
[3] Rigshosp, Dept Endocrinol & Metab, Copenhagen, Denmark
[4] Univ Copenhagen, Fac Hlth & Med Sci, Copenhagen, Denmark
[5] Herlev & Gentofte Hosp, Dept Pediat, Copenhagen, Denmark
关键词
cortisol; dried blood spot; fluispotter; hematocrit; LC-MS/MS; microsampling; CONGENITAL ADRENAL-HYPERPLASIA; TANDEM MASS-SPECTROMETRY; QUANTITATIVE BIOANALYSIS; EBF RECOMMENDATION; DBS; HEMATOCRIT; QUANTIFICATION; VALIDATION; COLLECTION; MS/MS;
D O I
10.4155/bio-2020-0048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aim: A novel automated serial dried blood spot (DBS) sampler, 'Fluispotter', was tested for its sampling performance. Materials & methods: An LC-MS/MS method was developed for the analysis of cortisol in DBS samples serially spotted by Fluispotter. The cortisol concentrations in 148 paired DBS and plasma samples were compared across a hematocrit (HCT) range of 22-55%. Results: The interassay accuracy and precision were <10%. Overall assay bias was negligible across the HCTs tested when analyzing the whole-spot DBS samples. The accuracy and precision of the blood volume in 10 mu l DBS samples spotted by Fluispotters and micropipettes were within 3%. Deming regression and Bland-Altman analysis showed a good agreement of DBS-predicted and measured plasma cortisol. Conclusion: The Fluispotter performed serial sampling with high accuracy and precision of the sample blood volume.
引用
收藏
页码:665 / 681
页数:17
相关论文
共 34 条
  • [1] Investigation of Different Approaches to Incorporating Internal Standard in DBS Quantitative Bioanalytical Workflows and Their Effect on Nullifying Hematocrit-Based Assay Bias
    Abu-Rabie, Paul
    Denniff, Philip
    Spooner, Neil
    Chowdhry, Babur Z.
    Pullen, Frank S.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (09) : 4996 - 5003
  • [2] Application of dried blood spots combined with HPLC-MS/MS for the quantification of acetaminophen in toxicokinetic studies
    Barfield, Matt
    Spooner, Neil
    Lad, Rakesh
    Parry, Simon
    Fowles, Susan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 32 - 37
  • [3] Quantification of amlodipine in dried blood spot samples by high performance liquid chromatography tandem mass spectrometry
    Chen, Gaoyun
    Jirjees, Feras, Sr.
    Al Bawab, Abdel
    McElnay, James C.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1072 : 252 - 258
  • [4] Choi R, 2019, ANN LAB MED, V39, P269, DOI [10.3343/alm.2019.39.3.269, 10.3343/alm.2019.39.3.263]
  • [5] The effect of hematocrit on bioanalysis of DBS: results from the EBF DBS-microsampling consortium
    de Vries, Ronald
    Barfield, Matthew
    van de Merbel, Nico
    Schmid, Bernhard
    Siethoff, Christoph
    Ortiz, Jordi
    Verheij, Elwin
    van Baar, Ben
    Cobb, Zoe
    White, Steve
    Timmerman, Philip
    [J]. BIOANALYSIS, 2013, 5 (17) : 2147 - 2160
  • [6] Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis
    Denniff, Philip
    Spooner, Neil
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (16) : 8489 - 8495
  • [7] Denniff P, 2010, BIOANALYSIS, V2, P1385, DOI [10.4155/bio.10.103, 10.4155/BIO.10.103]
  • [8] Evaluation of the Performance and Hematocrit Independence of the HemaPEN as a Volumetric Dried Blood Spot Collection Device
    Deprez, Sigrid
    Paniagua-Gonzalez, Lucia
    Velghe, Sofie
    Stove, Christophe P.
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (22) : 14467 - 14475
  • [9] An automated method on analysis of blood steroids using liquid chromatography tandem mass spectrometry: Application to population screening for congenital adrenal hyperplasia in newborns
    Dhillon, Kuldeep
    Ho, Thomson
    Rich, Patti
    Xu, Dadong
    Lorey, Fred
    She, Jianwen
    Bhandal, Ajit
    [J]. CLINICA CHIMICA ACTA, 2011, 412 (23-24) : 2076 - 2084
  • [10] Clinical feasibility of dried blood spots: Analytics, validation, and applications
    Enderle, Yeliz
    Foerster, Kathrin
    Burhenne, Juergen
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 130 : 231 - 243